Chapter 2
2-5
F-2-7
2.3.4 Initial Document Size Detection
0010-3901
The document length sensor 1 (PI4) and document length detection sensor 2 (PI5) detect the longitudinal size of the document placed on the document tray, and
the document width sensor 1 (PI2) and document width sensor 2 (PI1) detect the lateral size of the document.
When an document is placed on the document tray, detection levers of the two document length sensors move the light shielding plate to allow light pass through
the photo interrupter.
If the slide guide is adjusted to the document size, the two document width sensors mounted inside the document tray are shielded by the light shielding plate mount-
ed at the bottom of the slide guide.
Document sizes are determined by the combination of the ON/OFF states of document length sensors and the combination of ON/OFF states of document width
sensors.
F-2-8
The following tables show the relationships among document width sensors, document length sensors, and document sizes.
1. AB type
T-2-5
2. Inch type
Sensor name
Document width
sensor 1
Document width
sensor 2
Document length
sensor 1
Document length
sensor 2
Size
A3
ON
ON
ON
ON
B4
OFF
ON
ON
ON
A4R
OFF
OFF
ON
OFF
B5R
ON
OFF
ON
OFF
A4
ON
ON
OFF
OFF
A5R
ON
OFF
OFF
OFF
B5
OFF
ON
OFF
OFF
A5
OFF
OFF
OFF
OFF
B6
ON
OFF
OFF
OFF
ADF driver PCB
Document
Detection
lever
LAST
EMPTY
PI11
PI3
PI5
PI4
PI1
PI2
Содержание DADF-P1
Страница 1: ...Sep 14 2005 Service Manual Feeder DADF P1 ...
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 13: ...Chapter 1 Specifications ...
Страница 14: ......
Страница 16: ......
Страница 19: ...Chapter 2 Functions ...
Страница 20: ......
Страница 22: ......
Страница 35: ...Chapter 3 Parts Replacement Procedure ...
Страница 36: ......
Страница 72: ......
Страница 73: ...Chapter 4 Maintenance ...
Страница 74: ......
Страница 76: ......
Страница 83: ...Chapter 5 Error Code ...
Страница 84: ......
Страница 86: ......
Страница 88: ......
Страница 89: ...Sep 14 2005 ...
Страница 90: ......