----------------------------------FUNCTIONAL CONFIGURATION---------------------- 
                                     

 Local                    

Remote 

 Chassis/Slot                      

 Standalone               

Offline 

 User Port Speed/Duplex        

 Link Down 

 Switch Settings: 
    User Port Speed/Duplex        Autonegotiate 
    Side Band Mgmt                 

 Disabled 

    LLF Extension to User            Disabled 
    LLF User to Extension       

 Disabled 

 
 1) Configuration Option Control  Software 
 2) User Port Setting              

 100M/Full 

 3) Ext Port Setting               

 1000M/Full 

 4) RMTF                           

  Disabled 

 5) Link Loss Echo                 

  Disabled 

 6) Link Loss Fwd                  

  Disabled 

 
 
                                  Select [1-6]: 
------------------------------------Messages------------------------------------ 
Alarm Outputs: None 

Figure 11.  Functional Configuration screen 

 

Step 7:  Cable Connection 

Once the changes are made to the modules, the UTP (Unshielded Twisted Pair) or fiber optic 
cables can be installed.  Remember that the USR port is the port connected to your local/client 
device and the EXT port is the port facing the network/trunk.  Connect the fiber to the EXT port. 
 

                  

 

Figure 12.  Fiber optic and UTP cable connection

 

 

Step 8:  IP Address/Subnet Mask/Default Gateway Set-up 

From the System Configuration menu, type “5” then “enter” to access the IP/VLAN 
Configuration screen.  To configure the IP address, select “5,” press “enter,” and type the IP 
address you wish to assign to the unit.  Press enter to accept the changes.  The Subnet Mask and 
Default Gateway must be entered at this point as well. 
 

Содержание L357 ESU

Страница 1: ...E Parts List 1 x L357 xxxx 1 x UCS 1000 or UCS 1002 chassis 1 x UCS 1001 chassis 1 x UCS 1230 BAM Bus Access Module 1 x Model 1020 xxxx management access CPE or 1030 xxxx unmanaged CPE 1 x EIA 232 ser...

Страница 2: ...n Several options for installation are available for the L357 For applications requiring multiple modules in the same location depending on the size and quantity requirements the UCS 1000 UCS 1001 or...

Страница 3: ...ne 818 718 6300 FAX 818 718 6312 www canoga com P N 6942590 Rev A Page 3 of 8 Figure 2 L357 in UCS 1230 and UCS 1000 chassis Figure 3 L357 in UCS 1002 chassis Figure 4 L357 in UCS 1230 and UCS 1001 ch...

Страница 4: ...he STA LED will light up red SPD amber and FDX green after the boot up process All other LEDs on the module are off Step 5 Management Access To access the user interface of the L357 a VT100 session mu...

Страница 5: ...200bps Data bits 8 Parity None Stop bits 1 Flow control None Terminal emulation VT100 If the HyperTerminal screen is scrolling up make sure that Terminal Emulation in the Properties menu is set to VT1...

Страница 6: ...stics 6 System Log 7 Utilities 8 Software Upgrade 9 Change Password 10 Manage Logged In Users 11 Logout Select 1 11 Messages Alarm Outputs None Figure 10 Main Menu screen Step 6 Module Configuration F...

Страница 7: ...Loss Echo Disabled 6 Link Loss Fwd Disabled Select 1 6 Messages Alarm Outputs None Figure 11 Functional Configuration screen Step 7 Cable Connection Once the changes are made to the modules the UTP Un...

Страница 8: ...tem Configuration screen Canoga Perkins Corp EdgeAccess Ethernet Media Converter 30 Nov 2005 Model L357 1564 V02 00 F19 Standalone 09 35 14 IP SNMP AGENT CONFIGURATION Local Remote Offline MAC Address...

Отзывы: