Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008
Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com
P/N 6942590 Rev A
Page 2 of 8
UTP port configuration
Pin number (on PCB)
Function Switch
position
1 (SW1)
On
(Default)
2 (SW1)
Autonegotiate
On
(Default)
1 (SW1)
On
2 (SW1)
10Mbps
Off
1 (SW1)
Off
2 (SW1)
100Mbps
On
1 (SW1)
Off
2 (SW1)
1000Mbps
Off
Table 1. UTP port configuration
UTP and fiber port configuration
Pin number (on PCB)
Function On Off
3 (SW1)
User Port Duplex
Full Duplex
(Default)
Half Duplex
4 (SW1)
SideBand Management
Enabled
Disabled
(Default)
5 (SW2)
Link Loss Forwarding
Extension port to User port
Enabled Disabled
(Default)
6 (SW2)
Link Loss Forwarding
User port to Extension port
Enabled Disabled
(Default)
7 (SW2)
Not Used
N/A
N/A
8 (SW2)
Not Used
N/A
N/A
Table 2. UTP and fiber port configuration
Step 3: Module Installation
Several options for installation are available for the L357. For applications requiring multiple
modules in the same location, depending on the size and quantity requirements, the UCS 1000,
UCS 1001 or 1002 chassis may be used. The L357 is also hot-swappable module and it can be
inserted any time without interruption of service to other modules in the chassis.
Chassis or Enclosure
Maximum number of L357s
UCS 1000*
19 (AC Power) 21 (DC Power)
UCS 1001
4
UCS 1002*
9
UCS 1020
1
UCS 1030
1
*Note: Due to power requirements, the maximum number of L357s installable in the chassis
may be different if other modules are installed. Consult Canoga Perkins’ Tech Support for
further assistance.
Insert the L357 in an available slot in the 1230 or UCS 1002 making sure that the unit is lined-up
with the card guides. The module should slide into the slot with ease and make contact with the
rear connector without excessive force. Tighten the thumbscrew after insertion. The same steps
apply when installing in the UCS 1020 or 1030. See Figures 2 to 5.