Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008 

Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com 

P/N 6942590 Rev A  

 

Page 2 of 8

 

 

UTP port configuration  

 

Pin number (on PCB) 

Function  Switch 

position 

1 (SW1) 

On 

(Default)

 

2 (SW1) 

Autonegotiate 

On 

(Default)

 

1 (SW1) 

On  

2 (SW1) 

10Mbps 

Off 

1 (SW1) 

Off 

2 (SW1) 

100Mbps 

On 

1 (SW1) 

Off 

2 (SW1) 

1000Mbps 

Off 

Table 1.  UTP port configuration 

 

UTP and fiber port configuration 

 

Pin number (on PCB)

 

Function  On Off 

3 (SW1) 

User Port Duplex 

Full Duplex 

(Default)

 

Half Duplex  

4 (SW1) 

SideBand Management  

Enabled 

Disabled 

(Default)

 

5 (SW2) 

Link Loss Forwarding  
Extension port to User port  

Enabled Disabled 

(Default)

 

6 (SW2) 

Link Loss Forwarding 
User port to Extension port 

Enabled Disabled 

(Default)

 

7 (SW2) 

Not Used 

N/A 

N/A 

8 (SW2) 

Not Used 

N/A 

N/A 

Table 2. UTP and fiber port configuration 

 

Step 3:  Module Installation 

Several options for installation are available for the L357.  For applications requiring multiple 
modules in the same location, depending on the size and quantity requirements, the UCS 1000, 
UCS 1001 or 1002 chassis may be used.  The L357 is also hot-swappable module and it can be 
inserted any time without interruption of service to other modules in the chassis. 
 

Chassis or Enclosure 

Maximum number of L357s 

UCS 1000* 

19 (AC Power) 21 (DC Power) 

UCS 1001 

UCS 1002* 

UCS 1020 

UCS 1030 

 

*Note:   Due to power requirements, the maximum number of L357s installable in the chassis 
may be different if other modules are installed.  Consult Canoga Perkins’ Tech Support for 
further assistance.  

 
Insert the L357 in an available slot in the 1230 or UCS 1002 making sure that the unit is lined-up 
with the card guides.  The module should slide into the slot with ease and make contact with the 
rear connector without excessive force.  Tighten the thumbscrew after insertion.  The same steps 
apply when installing in the UCS 1020 or 1030.  See Figures 2 to 5. 
 
 

Содержание L357 ESU

Страница 1: ...E Parts List 1 x L357 xxxx 1 x UCS 1000 or UCS 1002 chassis 1 x UCS 1001 chassis 1 x UCS 1230 BAM Bus Access Module 1 x Model 1020 xxxx management access CPE or 1030 xxxx unmanaged CPE 1 x EIA 232 ser...

Страница 2: ...n Several options for installation are available for the L357 For applications requiring multiple modules in the same location depending on the size and quantity requirements the UCS 1000 UCS 1001 or...

Страница 3: ...ne 818 718 6300 FAX 818 718 6312 www canoga com P N 6942590 Rev A Page 3 of 8 Figure 2 L357 in UCS 1230 and UCS 1000 chassis Figure 3 L357 in UCS 1002 chassis Figure 4 L357 in UCS 1230 and UCS 1001 ch...

Страница 4: ...he STA LED will light up red SPD amber and FDX green after the boot up process All other LEDs on the module are off Step 5 Management Access To access the user interface of the L357 a VT100 session mu...

Страница 5: ...200bps Data bits 8 Parity None Stop bits 1 Flow control None Terminal emulation VT100 If the HyperTerminal screen is scrolling up make sure that Terminal Emulation in the Properties menu is set to VT1...

Страница 6: ...stics 6 System Log 7 Utilities 8 Software Upgrade 9 Change Password 10 Manage Logged In Users 11 Logout Select 1 11 Messages Alarm Outputs None Figure 10 Main Menu screen Step 6 Module Configuration F...

Страница 7: ...Loss Echo Disabled 6 Link Loss Fwd Disabled Select 1 6 Messages Alarm Outputs None Figure 11 Functional Configuration screen Step 7 Cable Connection Once the changes are made to the modules the UTP Un...

Страница 8: ...tem Configuration screen Canoga Perkins Corp EdgeAccess Ethernet Media Converter 30 Nov 2005 Model L357 1564 V02 00 F19 Standalone 09 35 14 IP SNMP AGENT CONFIGURATION Local Remote Offline MAC Address...