11 |
P a g e
Generator
Starting the Generator
1.
Before starting, check oil, coolant levels, sea strainer, and belts.
2.
Follow this procedure:
•
Turn the individual AC breakers off in pilothouse to avoid a surge to the electrical system.
•
Turn all AC main breakers off at the pilothouse.
•
Start the generator.
•
If it does not start right away, preheat the generator 10 seconds before starting it again.
•
Let the generator warm up a few minutes before turning AC Power selector to GEN.
•
Turn main generator breakers on in the pilothouse.
•
Turn on the individual AC breakers as needed.
Stopping the Generator
1.
Turn off the individual AC breakers to save a power surge on the system.
2.
Next, turn main generator breakers off in the pilothouse.
3.
Switch to shore power or inverting.
4.
Let the generator run a few minutes to cool down to avoid damage.
5.
Push the stop button.