18
A
Manual Reset
NOTICE:
Do not open the upper collar for the manual
reset procedure
Perform every 50 hours.
1. With your bike on the floor.
2. Cover the brake rotor with a clean shop towel.
Remove the Schrader valve cap and hold the
valve to release all air pressure. It is normal for
a small amount of oil to be expelled with the
escaping air.
WARNING
Contamination can result in reduced or
lost braking performance.
3. Hold the valve open while fully compressing
the LEFTY with the the handlebar until it
bottoms out. With the air out, using moderate
force, bottom out the LEFTY firmly several
times.
4. Now, measure from the bottom of the spindle
to the top of the outer collar. Repeat step
three until the correct measurement for your
LEFTY is reached.
LEFTY
LENGTH (A)
29”
578 +/- 3mm
26”
548 +/- 3mm
5.
When you are finished, reset sag. See page 6.
Measure Fully Compressed