NOTE :
A saved calibration file might be one that you have
received via e-mail, downloaded from the our
website, or one that is stored on a diskette or CD.
This button functions the same way as if you click
File - Open in the top right corner of the main
window.
Once “opened,” the file is ready for installation
into the vehicle ECU.
CAUTION
:
Before the saved file is sent to the ECU, be sure
to receive the vehicle variable or they will be
lost. Refer to "Receiving a calibration file
FROM THE ECU “Reading a map and
variables”" starting on page 33.
To open a saved calibration file,
NOTE :
In version 2.0 of the software, when the program
is launched, the last engine calibration file that
was opened is automatically open in the main
window. This feature is useful for servicing many
unit at once, however, be sure to check the engine
calibration file Numeric Cal ID code in the main
window to make sure that the right file is being
used. If not, complete steps 2 -3.
1. In the main window, click on the “OPEN
Calibration File (saved) button.
Use the Windows explorer to locate (browse for)
the saved engine calibration file.
Select the file and click OK.
2. The file is now “loaded” to the main window.
CAUTION
:
Check the Numeric Cal ID field in the main
window to make sure the filename selected is
displayed. If not, go back to step 2 and repeat.