CONVERSION FOR PROPANE/BUTANE (LPG MODELS ONLY)
LPG models are supplied adjusted for Propane (G31) at 37 mbar. To convert the
appliance to Butane (G30) at 28 – 30 mbar, the aeration of the hotplate burners
must be adjusted. This is done by reversing the aeration ring in the centre of the
burner body.
Large (Front Left and Rear Right) Burners
Small (Front Right and Rear Left) Burners
If the appliance is converted, the rating plate (located under the bottom of the
main oven door seal) should be corrected to show the current gas adjustment
conditions. A label is supplied with these instructions for this purpose, and should
be adhered over the section reading “This appliance is adjusted for ....................”
INSTALLATION INSTRUCTIONS
PROPANE (G31)
Smaller diameter hole
at top
BUTANE (G30)
Smaller diameter hole at
bottom
PROPANE (G31)
Smaller diameter hole
at top
BUTANE (G30)
Smaller diameter hole at
bottom