background image

Fitzroy Inbuilt 
Model shown.

Red LED flashes twice approximately every
3 seconds to indicate that power is available.
When heater is operating in Back Up mode
the LED is on continuously.

In the rare instance of the Hand Held Unit failing to operate, the heater can 
be operated manually by pressing the Back Up Switch button (once).

The switch is located where shown above.

For this Back Up Switch to operate correctly the batteries must be removed 
from the Hand Held Unit.

In this Back Up mode, the heater will start up on Low Fire and Low Speed 
Fan and then after approximately 3 minutes it will increase to High Fire and 
Medium Speed Fan. (Speed 2)

Turn off the heater, press the Back Up Switch (once), the fire will extinguish 
and the Fan will reduce to Low Speed and operate for approximately 
3 minutes to assist with cooling down the heater.

In this mode there is no temperature control operating.

Back Up Switch.

Page 17.

QUICK START GUIDE

This Remote Thermostat is a room thermostat and to function correctly it 
should be located in the same room as the heater within personal
comfort zone. 

 
The thermostat is factory set with the default settings shown below and 
will operate at settings indicated. If you wish to change these times or 
temperatures see the Programming section later in manual.

Automatic Factory default settings

Factory default settings

Time Period           Start Time                 Heat Temperature  (°C)

Wake up.                 6.00 am                       20 °C

Away.                      8.30 am                       7 °C

Coming home.        5.00 pm                       21 °C

Sleep.                    10.30 pm                       7 °C

The room will be maintained at set temperature during set period.

21°C

7°C

20°C

6.00AM

6.00AM

8.30AM

5.00PM

10.30PM

At any time during the automatic program period, the temperature can be 
increased or decreased by pressing the “

UP

” or “

DOWN

” buttons.

To start heater.

Select “

PWR

” and “

OK

” buttons and press them together (then release).

Select Auto or Manual by pressing “

A/M

” button (then release). 

The heater will only operate if the actual room temperature is lower 
than the required temperature.

Manual Mode: 

Press “

A/M

” Button to

 

select  “Manual” mode. 

The required temperature can be selected by using ‘

UP

 ’ or ‘

DOWN 

’ 

buttons.

Room temperature is shown at top of screen.
Selected temperature shown at mid screen.

Automatic Mode

Press “

A/M”

 Button to

 

select  “Auto” mode.

Set 

current

 time and date.  (See setting time and date later in manual.)

Page 2.

Содержание sampford IXL

Страница 1: ...THERMOSTAT USER MANUAL A M OK UP T P DOWN PWR ROOM TIME Cannon ...

Страница 2: ...n displays 12 Program mode 13 Factory default settings Your settings Settings 14 Change between C and F Restore factory default settings Teaching the thermostat ID code to the control unit Frequently asked questions 15 Quick reference table 16 Back Up Switch 17 Service 18 Battery type 2 X AA batteries Battery life approximately 12 months Transmission frequency 433 92 Mhz Dimensions 140MM x 80mm x ...

Страница 3: ... at set temperature during set period 21 C 7 C 20 C 6 00AM 6 00AM 8 30AM 5 00PM 10 30PM At any time during the automatic program period the temperature can be increased or decreased by pressing the UP or DOWN buttons To start heater Select PWR and OK buttons and press them together then release Select Auto or Manual by pressing A M button then release The heater will only operate if the actual roo...

Страница 4: ...y are restrained from the front top and sides of the heater The manufacturer takes no responsibility if curtain clearance is less than 900mm and not restrained For full safety warning information Refer to Heater User Instructions Page 3 CAUTION The thermostat has already been programmed with a unique code Do not attempt to teach the RF Thermostat ID code unless instructed by the manufacturer This ...

Страница 5: ... below As the preset temperature is reached the heater will go to Low Fire and Low Fan When the heater preset temperature is exceeded the burner is extinguished and the fan will run on at low setting for approximately 3 min If room temperature is still higher than preset temperature the heater will stop Once room temperature drops below preset temperature the heater will resume operation and conti...

Страница 6: ...gh 6 Selected Temperature in C or F 7 Time of day in AM or PM 8 Day of week 9 Programming mode 10 Manual mode 11 Automatic mode Although a medium Fire is displayed it is not available on this heater it is actually operating on High Fire when displayed Initial Display on set up The display when the thermostat is initially turned on or when batteries are replaced shows Current room temperature defau...

Страница 7: ... 32 C When the thermostat is on the programmed set temperature will be displayed When the thermostat is off only the room temperature will be displayed Indicates that the thermostat is transmitting to the receiver the symbol will appear on the LCD for 1 second Indicates that battery power is below an acceptable level The symbol will flash to indicate that the batteries need replacing The thermosta...

Страница 8: ...escription PWR OK UP DOWN PWR UP DOWN OK Switches the thermostat on If the thermostat is off pressing and releasing the PWR and OK button together will turn the thermostat on to the most recently selected working mode On Accepts the current function and advances the next function Increment hours minutes day or temperature Decrement hours minutes day or temperature Enter Button Functions PWR OK A M...

Страница 9: ...WN button to increase or decrease the minute setting by 1 minute similarly to the hour setting Press OK to accept and select the day of the week Setting the day of the week function Press and release the UP or DOWN button to change the day of the week to the following or previous day Press and hold the UP or DOWN button for 2 seconds or longer to increase or decrease the day of the week by 1 day e...

Страница 10: ...will be operating on High Fire when Medium fire symbol is displayed Adjusting the temperature In the manual mode adjust the set temperature by pressing or releasing the UP or DOWN buttons Press and hold the UP or DOWN buttons to increase or decrease the temperature by 1 C every 0 5 seconds Automatic mode The automatic mode allows the temperature to be regulated according to a programmed level and ...

Страница 11: ...4 night time Sleep To begin programming With the thermostat off press and hold the P button for 2 seconds or longer to initiate programming The LCD will display PROG Pd and the time at which the thermostat is currently set MO will flash Period 1 can now be set Setting the day of the week You must choose which day s of the week you wish to program Press and release the UP or DOWN button to change t...

Страница 12: ...ess OK Setting the temperature The temperature setting will now flash Press and release the UP or DOWN button to increase or decrease the temperature setting by 1 C Press and hold th UP or DOWN button for 2 seconds or longer to increase or decrease the temperature setting by 1 C every 0 5 seconds To accept the temperature press OK Period 1 is now set for the day s of the week that you have chosen ...

Страница 13: ...TIME AM SU MO TU WE TH FR SA PROG ROOM SET TIME AM MO PROG ROOM SET TIME AM MO PROG SET TIME AM MO PROG Set period day Days of week flash Set temperature Set and temperature flash Period 2 Period 1 Period 3 Set hours Time and hours flash Set minutes Time and minutes flash Page 12 ...

Страница 14: ... settings Time Period Start Time Heat Temperature C Wake up 6 00 am 20 C Away 8 30 am 7 C Coming home 5 00 pm 21 C Sleep 10 30 pm 7 C Time Period Start Time Heat Temperature C Wake up C Away C Coming home pm C Sleep pm C Time Period Start Time Heat Temperature C Wake up C Away C Coming home C Sleep pm C The room will be maintained at set temperature during set period pm ...

Страница 15: ...rmostat off press the following sequence of buttons P T T UP Restore factory default settings The automatic mode factory default settings can be restored to those found on page 10 With the thermostat off press the following sequence of buttons P T T DOWN The thermostat temperature display can be set to C or F The default is C With the thermostat off press the following sequence of buttons P T T A ...

Страница 16: ...ith new batteries and see if thermostat display appears Check safety interlock mode The back light will only appear when the thermostat is on Heater comes on at the wrong temperature The time or day of the week is wrong Factory default settings have been lost The thermostat won t turn on or the display is blank The screen back light is not working Page 15 Normal operation If there is a request for...

Страница 17: ... 0 5 seconds Press OK and set the minute setting similarly Press OK and press and release the UP or DOWN buttons to change the day of the week With the thermostat off press and hold the P button Program 1 can now be set To select Monday press OK or press and release UP or DOWN to change the day of the week or to switch to the weekday or weekend setting To set the period starting time set the hour ...

Страница 18: ... shown above For this Back Up Switch to operate correctly the batteries must be removed from the Hand Held Unit In this Back Up mode the heater will start up on Low Fire and Low Speed Fan and then after approximately 3 minutes it will increase to High Fire and Medium Speed Fan Speed 2 Turn off the heater press the Back Up Switch once the fire will extinguish and the Fan will reduce to Low Speed an...

Страница 19: ...No user serviceable components are within the heater thermostat contact SampfordIXL for any required maintenance Ph 1300 727 421 Fax 1300 727 425 Page 18 NOTES For Service ...

Страница 20: ...Phone 1300 727 427 Faxsimile 1300 727 425 F3197 ISSUE 2 JAN 2009 ...

Отзывы: