background image

Manual mode

Flame height and Fan speed.

The

mode allows setting the temperature at any level.

To select Manual mode, firstly the thermostat must be turned on, then press
and release the ‘

’ button until

appears on the display.

The flame height and fan speed are linked for safety purposes and are not
independently adjustable. The flame height and fan speed are set by the
thermostat according to the difference between the set temperature and the
current temperature. They are automatically controlled by the thermostat in
the program cycle.This will vary according to the selected temperature and
the actual room temperature.

manual

A/M

MANUAL

Adjusting the temperature.

In the

mode, adjust the set temperature by pressing or releasing

the ‘

or ‘

’ buttons.  Press and hold the ‘

’ or ‘

’ buttons

to increase or decrease the temperature by 1°C every 0.5 seconds.

manual

UP’

DOWN

UP

DOWN

Automatic mode.

To correctly operate in

mode, the time and day of the week

must be set.

Manually overriding the set program.

The

mode allows the temperature to be regulated according to a

programmed level and time.

With the thermostat on, press and release the ‘

’ button until the word

AUTO appears on the LCD.

The thermostat will now operate according to the program set for the
current time period.  Programming instructions are found on page 10.

At any time, the temperature or fan speed may be adjusted up or down
similar to operating in

mode.

However, whenever the thermostat changes to a new time period, the
temperature will be

automatically according to that period’s setting.

automatic

A/M

manual

reset

automatic

Page 9.

Programming

Each day of the week can be programmed individually for periods P1, P2,
P3, and P4, making a total of 28 programmed periods.

Alternatively, a weekday program can be set, so the same program is used
for Monday to Friday.  Similarly, a weekday program can be set for Saturday
- Sunday. The entire week can also have the same program.

Alternatively, a weekday or weekend program can be set with individual
programs for the remaining days.

The suggested period settings for each day(s) are:

Period 1 - morning       (Wake up)
Period 2 - daytime       (Away)
Period 3 - evening       (Coming home)
Period 4 - night time.   (Sleep)

With the thermostat off, press and hold the ‘ ’ button for 2 seconds or longer
to initiate programming. The LCD will display

and the time at

which the thermostat is currently set

will flash.

Period 1 can now be set.

To begin programming.

PROG, Pd

MO

P

Setting the day of the week.

You must choose which day(s) of the week you wish to program.
Press and release the ‘

’ or ‘

’ button to change the day of the week

to the following or previous day. Press and hold the ‘

’ or ‘

’ button

for 2 seconds or longer to increase or decrease the day of the week by
1 day every 0.5 seconds.
The order that you can scroll through the days is as follows:

UP

DOWN

UP

DOWN

To accept the selected day(s) of the week press ‘

’.

OK

Page 10.

MO>TU>WE>TH>FR>MO TU WE TH FR>SA>SU>SU SA>MO TU WE TH FR SA SU

Содержание GMK10025

Страница 1: ...lease leave instructions with the owner Cannon For service to this appliance or spare parts contact the CANNON distributor Email aftersalesservice sampfordixl com au Date installed Compliance Certificate No Sampford IXL Spare Parts Phone 1300 727 421 Fax 1300 727 425 PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING THIS PRODUCT Part Number F3754_D ...

Страница 2: ...le 16 Back Up Switch 17 Service 18 Features 4 6 Frequently asked questions 15 Battery type 2 X AA batteries Battery life approximately 12 months Transmission frequency 433 92 Mhz Dimensions 140MM x 80mm x 20mm Page 1 NOTES CONTENTS INITIAL START UP 1 Disconnect heater from power supply 2 Fitted batteries to remote thermostat unit 3 connect Heater back to power supply and point Remote Thermostat at...

Страница 3: ...lease PWR OK A M Press Button to select Manual mode Room temperature is shown at top of screen Selected temperature shown at mid screen The heater will only operate if the actual room temperature is lower than the required temperature Manual Mode The required temperature can be selected by using or buttons A M UP DOWN To start heater Select and buttons and press them together then release Select A...

Страница 4: ... of the heater is described in more detail in the following section This heater features a safety interlock mode to prevent accidental or inappropriate activation of the hand held remote control unit It requires both and buttons be pressed at the same time to turn on the controller PWR OK Page 16 Function Action Page Switch on off Change between manual and automatic mode Increase decrease temperat...

Страница 5: ...uto or Manual The heater on start will operate on Low Fire and fan for approx 3 minutes The heater will then go to your preset desired settings on remote thermostat As the preset temperature is reached the heater will go to Low Fire and Low Fan If the preset temperature is exceeded the burner is extinguished and the fan will run on at low setting for approximately 3 min If room temperature is stil...

Страница 6: ... The thermostat temperature display can be set to C or F The default is C With the thermostat off press the following sequence of buttons P T T A M Please note thermostat settings need to be actioned within a period of 15 seconds total 2 1 Leave the remote thermostat in the off or stand by position the room temperature and time only will be displayed 2 The heater must be turned off at its switch l...

Страница 7: ...and minutes AM or PM The time is displayed when the thermostat is on or off Displays the current day of the week The day is displayed when the thermostat is on or off Displays the current temperature C is the default but F is available The temperature range is 7 C to 32 C When the thermostat is on the programmed set temperature will be displayed When the thermostat is off only the room temperature...

Страница 8: ... 2 or more seconds when thermostat is off Indicates the programming mode must press and hold for 2 or more seconds when thermostat is off Functions Button Function Description PWR OK UP DOWN PWR UP DOWN OK Switches the thermostat on If the thermostat is off pressing and releasing the PWR and OK button together will turn the thermostat on to the most recently selected working mode On Accepts the cu...

Страница 9: ... set Page 8 Note Use the outer edge of buttons to toggle through functions With the thermostat off press and hold the button for 2 seconds or longer to initiate programming the time the setting and the AM PM will flash T Time hour Page 11 Setting the period starting time The hour and AM PM settings will now flash To set the P1 starting time press and release the and button to increase or decrease ...

Страница 10: ...d up or down similar to operating in mode However whenever the thermostat changes to a new time period the temperature will be automatically according to that period s setting automatic A M manual reset automatic Page 9 Programming Each day of the week can be programmed individually for periods P1 P2 P3 and P4 making a total of 28 programmed periods Alternatively a weekday program can be set so th...