TROUBLESHOOTING

you will require a digital multimeter with the functions
to measure AC/DC voltage, continuity, resistance and

It is critical that the appliance is

earthed and that the active and

neutral are not reversed.

Cannon Inbuilt Power Flue

There is a green and red LED on the ignition controller. These LEDs act as diagnostic aids when the heater safety
systems produce a safe shutdown condition.

Green LED: this is on when the flame is sensed at the flame sensor electrode.

Red LED: this flashes according to the fault code.

No LEDs means there is no power to the ignition module. Check that the heater switch is set to ON by pressing the
ON/OFF button. Check the supply voltage. Check the 1.5 Amp fuse, replace if necessary. It is critical that the appliance
is earthed and that the active and neutral are not reversed. Do not use an extension cord. This appliance is designed
to operate at 240V AC. Substantial voltage dips, or running the unit at voltages substantially lower than 240V AC may
cause nuisance shutdowns. If there is still a problem check the power supply plug from the electronic controller with a
multimeter (240V AC). If there is no power from this plug when the heater should be on, replace the electronic controller.
Remember to re-test the gas pressures any time that the electronic controller is changed. It is recommended that any
callout to a customer’s home should prompt the checking and resetting of the gas pressures.

Fault Codes

Long Short Morse Code Meaning

Action

1

5

—•••••

Normal start-up (30
second combustion
purge)

1

0

Normal operation

2

1

— —•

Heater has
attempted to light,
however it did not
sense flame within
the allowed time.

Check the gas supply to the unit is not switched off. Check
the gas pressures. Check the flame and spark electrode
connections and that they are positioned correctly. Ensure that
the spark is being produced at the spark electrode tip, and
is strong (clearly visible and around 6-8mm in length). Adjust
if necessary. The burner tray is earthed through contact with
the chassis. Check using a multimeter between the earth pin
(or earth tab) and the burner tray. If the unit continues to spark
after flame is present, ensure that the supply voltage polarity is
not reversed.

2

2

— —••

Flame was estab-
lished, however
the flame electrode
has sensed that the
flame has become
unstable and has
shutdown the gas.

Check that the flame sense electrode and the spark plate are
correctly positioned. Check the flame sense connections.
Check that the flue is correctly constructed. Abnormally
strong downdrafts can cause flame instability therefore it is
recommended that an appropriate flue cowl is used for windy
areas. Improper gas pressures can also cause issues. Check
the gas pressures.

1

2

—••

Room fan (circulation
fan) pressure signal
not detected.

Check the fan for dust build up and lint. Check that the
room air fan is spinning. Check that the pressure tubes are
connected correctly and not pinched or kinked. The black tube
should run from the black side of the pressure switch to the
bottom tapping on the fan venturi. The clear tube should go
from the light side of the pressure switch and to the top tapping
on the venturi. Make sure that the pressure switch wires are
connected correctly. One wire should be to C (Common) and
the other should be to NO (Normally Open). If it still doesn’t
work after checking the above, change the pressure switch.

To check the operation of the heater’s electrical system

micro-amps.

20 | Cannon Power Flue

Содержание Fitzroy FITZIB-PMEXx

Страница 1: ...leave instruction manual with the owner Distributor This appliance is designed manufactured and distributed by Tel 1300 727 421 Models FITZIB PMEXx Models CANTIB PDEEx Fitzroy Canterbury x Colour Shar...

Страница 2: ...ECIFICATIONS 8 CANTERBURY INBUILT POWER FLUE SPECIFICATIONS 9 REGULATORY LOCATOR 10 POWER FLUE INSTALLATION INSTRUCTIONS 11 14 FASCIA REMOVAL AND ELECTRICAL CONNECTION 15 LOG INSTALLATION GAS CONNECTI...

Страница 3: ...in accordance with the manufacturer s instructions d will not cover faults due to normal wear and tear with reasonable use nor consumable components such as globes filters glass items etc e will not c...

Страница 4: ...ng order Privacy The privacy of your personal information has always been important to us To learn more about how we collect keep and use your personal information please obtain a copy of our privacy...

Страница 5: ...take care to avoid burns or clothing ignition This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowle...

Страница 6: ...AL turn the heater on again if there have been several attempts to ignite the heater without success If there is an interruption to the power supply the heater will fail safely and switch off When the...

Страница 7: ...l lation options Install in a shallow recess or an existing fireplace elegant spacers will eliminate any size discrep ancies To enhance your Cannon s appearance add a decorative 3 or 4 sided surround...

Страница 8: ...lator Integral part of controller Min inlet pressure 1 13 kPa NG 2 75 kPa Propane Fan 3 speed Ignition Electronic direct spark Power requirement 240V AC 10 Amp switch socket Power consumption 90 VA ma...

Страница 9: ...r Integral part of controller Min inlet pressure 1 13 kPa NG 2 75 kPa Propane Fan 3 speed Ignition Electronic direct spark Power requirement 240V AC 10 Amp switch socket Power consumption 90 VA maximu...

Страница 10: ...FLUE HEATER IS FAN ASSISTED SEE COLUMN HIGHLIGHTED a Below eaves balconies and other projections Appliances up to 50 MJ hr input 300 200 Appliances over 50 MJ hr input 500 300 b From the ground above...

Страница 11: ...r or out through the terminal when installed horizontally The exhaust gas flue pipe must not trap and collect condensation This will adversely affect the performance of the heater POWER FLUE INSTALLAT...

Страница 12: ...m lengths Place a liberal amount of silicon sealant to the inside of the flexible flue pipe which is to be mounted onto the flue exhaust outlet Slip the flexible aluminium hose over the flue exhaust...

Страница 13: ...to seal the join and a hose clamp 3 Fit the PVC tubing and the air inlet to the other flexible tube using a hose clamp 4 Place terminal cover plate over both air intake and exhaust air pipes 5 Fit th...

Страница 14: ...ving Canterbury Fascia To fully remove the fascia unclip the switch cable from the cable connector on the PCB and unclip the cable from the clipping points on the rear of the fascia Electrical Connect...

Страница 15: ...d side of the heater at the bottom Refer FIG 26 2 With heater in position flanges should be hard against masonry Secure case flanges to the masonry Screw or bolt the flange through the slots provided...

Страница 16: ...8 9 Turn clockwise to increase pressure and anti clockwise to decrease pressure FIG 32 Refer 5 Remove spanner and screwdriver Switch from BOOST to LOW to ensure settings are correct 6 Switch heater of...

Страница 17: ...ion module 3 Lift ignition module from base panel 1 Remove the fascia Refer to page 14 of the installation manual 2 Disconnect the plugs on electronic controller Note Hook and loop mounting tape is us...

Страница 18: ...hould be positioned in pointer 2 1 Remove the fascia Refer to page 14 of the installation instructions 2 Remove the electronic controller and ignition module Refer to page 17 3 Disconnect the fan plug...

Страница 19: ...an is parallel to the top panel shown in Then remove the combustion fan making sure that it does not hit the male thread used to secure room circulation fan 9 Disconnect the electrical wiring off the...

Страница 20: ...hin the allowed time Check the gas supply to the unit is not switched off Check the gas pressures Check the flame and spark electrode connections and that they are positioned correctly Ensure that the...

Страница 21: ...the fan or check to see if air is blowing out of the flue pipe Check that the pressure tubes are connected correctly and not pinched or kinked The black tube should run from the black side of the pre...

Страница 22: ...NOTES 22 Cannon Power Flue...

Страница 23: ...Cannon Power Flue 23 NOTES...

Страница 24: ...Certificate No Installed By COPY RATING LABEL HERE Don t Risk Your Appliance Warranty Only a licensed person will give you a compliance certificate showing that the work complies with all the relevan...

Отзывы: