POWER FLUE INSTALLATION INSTRUCTIONS
FIG 8
Fitzroy shown. (Same dimensions for Canterbury)
Preparing The Cavity
The power flue heater is a high efficiency unit extracting
heat which in other heaters would escape in the flue
gasses. Condensate from the flue gasses will be produced
from this heater.
A condensate drain pipe fixed to the exhaust flue outlet
MUST have a condensate hose connected to it to allow for
any condensation to drain out of the house. This hose
must be fitted prior to installation of the heater into the
The floor of the cavity MUST be smooth, flat and level.
Using your template as a guide, mark the flue cutout on
the rear wall of the cavity and cut through from either the
inside or the outside to produce a neat round hole in the
external wall.
If you desire a template, use a sheet of stiff cardboard or
MDF (medium density fibre board) cut to represent the
rear of the heater. Mark a vertical centre line and an
appropriate circle 450mm from the bottom indicating the
flue position cut out. Refer
FIG 10.
Two lengths of flexible aluminium hose is supplied with
the heater. These hoses can be stretched to 1 m lengths.
Place a liberal amount of silicon sealant to the inside of
the flexible flue pipe which is to be mounted onto the
flue exhaust outlet.
Slip the flexible aluminium hose over the flue exhaust
outlet with a hose clamp. Tighten the hose clamp to ensure
the hose is securely attached to the flue exhaust outlet.
The flexible aluminium hose is attached to the air inlet in
the same manner, however there is no need to apply the
silicon sealant on the air inlet.
Secure condensate tube to drain pipe using supplied
12 | Cannon Power Flue
695 mm
100 mm **
X
NOTE: X = 50 mm for Non Combustible Surfaces
X = 100 mm for Combustible Surfaces
** Ensure controls are visible
80 mm Gas Supply
FIG 10
Front View
FIG 12
Corner Wall Application Fitzroy shown.
(Same dimensions for Canterbury)
FIG 11
Air Inlet Flue Outlet
Condensate Drain
25 mm MIN
25 mm MIN
512 mm
512 mm
379 mm
*1*
*2*
FIG 9
Front View
Mark and cut hole
in rear
Wall of the cavity for flue
and condensation drain
Floor MUST be
smooth and flat
Note: *1* For any horizontal application the top hat
section can be removed.
*2* Condensation drain hose MUST have
sufficient fall to provide adequate
drainage. Ensure no water traps in drain
hose.
700 mm
120 mm
266 mm
288 mm
605
mm
410
mm
450 mm
41
mm
GAS SUPPLY
160 mm DIA
FLUE OPENING
20 mm DIA
CONDENSE
DRAIN HOLE
cavity.
clamp.