Cannon Fitzroy Inbuilt Power Flue | 13
fasCia reMoVal / installation
1. remove the wire mesh guard by gently lifting it
upwards and then outwards. Similarly remove a fitted
glass kit by also gently lifting it upwards and then
outwards.
2. remove 4 M5 screws fixing the fascia assembly to the
heater body. Bring the bottom of the fascia towards
you gently to partly disengage it from the body of the
heater. after it has been disengaged gently lift it up
vertically to completely disengage it from the body of
the heater. refer
FIG 20 &
FIG
21
.
Inner Glass Removal
To remove the inner glass loosen off all the clamp screws
and completely remove the upper clamps and one
vertical side. Try not to touch the front surface of the
glass to avoid finger marks use suitable cloth. remove
the glass by sliding the glass sideways out of the clamp
and then lifting out from the bottom. Place the glass in a
safe position for refit later.
fig 20
fig 21
to fully remove the
fascia, unclip the switch
cable from the cable
connector on the PCB
and unclip the cable from
the clipping points on
the rear of the fascia.
Electrical Connection
This appliance is designed to operate on 240v aC power
supply. Failure to operate unit at correct supply voltage
may create unsafe conditions.
The heater is supplied with a flexible power cord with
a plug fitted. a 10 amp switch socket must be located
within 1.5m of the heater. For installations where the
power point is located outside of the enclosure, locate
the power cord in the fascia cut out on the left or right
hand side as required.
For a power supply connection located inside the
enclosure run the power cord through the cord access
located on the rear panel by pushing the cord access
plate from the bottom. The rubber grommet that is fitted
over the cord must be located correctly in the cut out of
the cord access plate. refer
FIG 22
.
restore the cord access plate to the original position and
seal with an appropriate removable material.
A suitable
double pole isolation switch must be installed
externally for servicing or emergency shut down
of the heater.
all fixed wiring must be installed by a suitably
qualified person and comply to the appropriate
electrical wiring rules.
eleCtriCal ConneCtion
fig 22
grommet
It is critical that the appliance is earthed and that
the active and neutral are not reversed. Issues
arising from incorrect electrical wiring at premises
will not be covered under warranty (including use
of extension cords). We recommend that the heater
is connected directly to a switch socket by its own
power cord. Refrain from using extension leads.