3
The Cannon appliance is warranted against defects in materials and work-
manship for a period of one, (1) year from its date of original purchase, for
residential use in Australia.
Warranty service, which includes parts and labour for the replacement or
repair of defective parts, is available through the CANNON distributor.
(Details below or on page19).
Consumers are responsible for service person’s travel outside normal serv-
ice areas (approximately seventy (70k) radius from the nearest Cannon
dealer’s location), local cartage, and normal maintenance as described in
this manual.
Any product subjected to misuse, abuse, negligence, accident or alteration
will have its warranty voided. The defacement of serial plate will have its
warranty voided.
If installation is not carried out in accordance with manufacturer’s instruc-
tions, this warranty may be void.
The customer must keep their “Tax Invoice” as proof of purchase of this
product, and compliance certificate as proof of required installation.
Model number: ______________________________________
Serial number: _______________________________________
Date of manufacture: _________________________________
Date installed: _______________________________________
Compliance Certificate No: ____________________________
Warranty
Don’t risk your appliance warranty
Only a licensed person will give you a Compliance Certificate,
showing that the work complies with all the relevant standards.
And only a licensed person will have insurance protecting their
workmanship for 6 years.
So make sure you use a licensed person to install this appliance
and ask for your Compliance Certificate to ensure the manufactur-
ers appliance warranty will be honoured.
Distributor
This appliance is designed, manufactured and distributed by:
Tel: 1300 727 421
22
9.
No gas to burner.
• The gas valve should open at the same time as the
igniter sparks. If there is no gas to the burner when
this occurs check the solenoid coils for continuity.
• Check that the gas pressure is present at the test
point when the spark is being generated.
• Check that there is gas to the inlet of the gas control.
10.
Appliance lights but goes
• Test the flame for correct ionisation signal. Connect a
into lockout.
multimeter in series with the flame rod and set the
function to measure micro-amps. The module will go
into lockout if the flame current sensitivity is less than
0.5 micro-amps. The approximate signal strength on
high flame is about 10 micro-amps and on low
4 micro-amps. The signal strength will fluctuate but
should be greater than 1.5 micro-amps at all times.
Take precaution because the ionisation probe can
have a high negative voltage and can cause shock.
11.
Fuse blowing.
• If the fuse continues to blow check the solenoid coils
for signs of them being shorted.
• Check the fan and wiring for short circuit.
Connections
Terminals 5, 6 and 7 at the module 12 way connector are bridged.
Terminal 10 at the module 12 way connector is the active supply via the
red wire.
Terminal 11 at the module 12 way connector is the neutral supply via the
blue wire.
Terminal 12 at the module 12 way connector is the earth connection via
the green/yellow wire.
Terminal 12 at the module 2 way connector is the neutral connection via a
brown wire which is joined into the rectifier cable then into the 8 way
switch connector blue wire.
Terminal 14 is an active connection at the module 2 way connector via a
white wire into the 8 way switch connector. This is active only when the
flame is sensed.