10
1. This appliance is to be installed by a licensed service person only.
2. This appliance shall be installed in accordance with the manufacturer’s
installation instructions, local gas fitting regulations, municipal building
codes, electrical wiring regulations, and AS5601 the Australian Stand-
ard for gas installations. Refer also to AS5601 for pipe sizing tables.
THIS HEATER IS NOT INTENDED FOR FIRE PLACE INSERT.
Clearances
3. Ensure the minimum clearances to combustible construction are main-
tained during installation, including adequate space for the proper
operation and servicing of the heater.
For clearances to curtains and furnishing refer to warning 3 & 4 on
page 4.
For minimum clearances refer fig 9 and 10.
4. Remove the carton from the heater and lift from pallet.
Check that the heater is suitable for the gas available. Refer to the data
label located on fan chamber base, rear of pedestal front.
(Please dispose of packaging appropriately, keep away from children).
5. Prepare electrical and gas connections, a 10 Amp wall socket needs
to be located within 1.5m of the heater.
Note: if flexible cord is damaged, disconnect from supply socket. Re-
move the damaged flex and replace with spare-part assembly F2799.
6. Fit rear spacers as per figure 10.
Installation
7. Place heater in position. (Check flue and gas connection positions.
Refer to gas connection instructions on page 12 and flue installation
instructions on pages 16 & 17).
10
Installation instructions
9
15
23. Follow User Instructions to turn on heater and test for correct operation
before leaving.
24.The heater flames should be stable, not lifting from burner and the logs
should glow after approximately 15 minutes operation on HIGH set-
ting.
The heater has been designed to burn with luminous flames, which
mimic natural log combustion, and may exhibit slight carbon deposits.
If heavy carbon deposits occurs or flames impinge on the roof of the
combustion chamber, turn the appliance off and contact the service
agent in your state.
25.If after following these installation instructions and the trouble shooting
chart on page 20-21, the heater does not perform correctly contact the
service agent in your state. For details of service agents please refer
page 19.
Installation tips
❍
Make sure that the heater is fully commissioned and be certain to con-
duct a test of the integrity of the flue operation, taking into account any
influences created by range-hoods, exhaust fans, central heating, etc.
❍
To avoid any unnecessary delays and inconvinience to your customer,
please contact our Technical Services Department on 1300 727 421,
if the installation is unusual or you have any concerns with the installa-
tion and/or heater operation before the installation commences.
❍
Any service request resulting from incorrect installations are not covered
by our warranty conditions and these calls will result in charges, usually
to the end user, so please be sure that the installation and commission-
ing has been satisfactorily carried out before calling for a warranty
service.
❍
Please make sure that the end user is fully instructed on how to operate
the heater.