16
For natural gas connection;
Ventilation Of Room
The air needed for burning is received from room air and the gases emitted
are given directly in room. For safe operation of your product, good room
ventilation is a precondition. If no window or room to be utilized for room
ventilation is available, additional ventilation should be installed. However,
room has a door opening outside, it is no needed to vent holes.
Room size
Ventilating opening
Smaller than 5 m³
min. 100 cm²
Between 5 m³ - 10 m³
min. 50 cm²
Bigger than 10 m³
No need
In basement or cellar
min. 65 cm²
Main Gas Pipe
Gasket
Nut
Natural Gas
Connection Hose
WARNING:
Natural gas connection should
be done by authorized service.
For natural gas connection, place gasket
in the nut at the edge of natural gas connection
hose. To install the hose on main gas pipe,
turn the nut. Complete the connection by
making gas leakage control.
GB
Содержание OCGF12B
Страница 25: ...25 Figure 11 560 600 35 500 30 30 555 545 595 595 565 22 Figure 12...
Страница 26: ...26 590 550 560 35 500 30 30 Figure 13 GB...
Страница 66: ...66 Figura 11 560 600 35 500 30 30 555 545 595 595 565 22 Figura 12 IT...
Страница 67: ...67 590 550 560 35 500 30 30 Figura 13...
Страница 108: ...108 Figura 11 560 600 35 500 30 30 555 545 595 595 565 22 Figura 12...
Страница 109: ...109 590 550 560 35 500 30 30 Figura 13 ES...
Страница 149: ...149 560 600 35 500 30 30 Figura 11 555 545 595 595 565 22 Figura 12 PO...
Страница 150: ...150 590 550 560 35 500 30 30 Figura 13...
Страница 191: ...191 Rys 11 560 600 35 500 30 30 555 545 595 595 565 22 Rys 12...
Страница 192: ...192 590 550 560 35 500 30 30 Rys 13 PL...
Страница 231: ...231 Obr zek 11 560 600 35 500 30 30 555 545 595 595 565 22 Obr zek 12...
Страница 232: ...232 590 550 560 35 500 30 30 Obr zek 13 CZ...