FUNCTIONING

Control Panel

35

30 24

27

28

34

33

36

31

32

29

24.- Display
27.- Setting key
28.- Setting key
29.- Central Heating switch
30.- Green indicator – Central Heating mode ON
31.- Central Heating temperature reducing key
32.- Central Heating temperature increasing key 
33.- Green indicator – Power ON
34.- Orange indicator - Burner ON 
35.- Red indicator - Lock out / flame failure
36.- Reset key

Switching on

1. Check that pressure in central heating system is above 0.7 bar and below 1.5 bar with the pressure gauge 16.

2. Check that the gas service tap is opened at the gasmeter and main power is on. Green indicator 

Power ON 33.

3. Open the gas tap 

39 (fig.21).

The boiler is now ready to use.

Attention ! If the boiler stays a long time without working, some air in the gas pipe can hinder the first lightings. (please refer to para-

graph 19 Incorrect Function)

Switching on Central heating

Press on key 29

, the green indicator 30 will light and the display will show the Heating 

flow temperature. 

Keys 

31

and 32

allow to adjust the temperature required in the Central Heating system 

regarding the weather conditions.

• press 

to increase temperature when weather is cold

• press 

to reduce temperature when weather is fair

During the temperature setting operation the display will flash.
If the room thermostat is calling for heat, a dot will be displayed at the bottom of the 3rd digit 

Turn off the boiler

- Press on key 29

, to switch off CH mode. The green indicators 30 will stop

- Switch off the main electrical supply
- Shut off the gas service tap 39 (fig. 21)

Note : In this conditions, the anti-freeze system is inoperative

Stand by mode

A fixed digit at the centre of the display and the green indicator 33 on

Putting the boiler in stand by mode and anti freeze system. :

Press on key  29

, to switch off CH mode. The green indicators 30 will stop.

During the all duration of the stand by mode, an automatic anti-sticking system will switch on the pump for 1

minute and make a movement of the 3 way valve each 23 hours.
The stand by mode will disable the anti-freeze function of the room thermostat (if fitted). To leave the  room thermostat
anti freeze system operative, please let the Central Heating mode on.
The boiler is equipped with an automatic anti freeze system which permanently on.

If the Central Heating temperature decrease bellow 7°C, the pump will start.
If the Central Heating temperature decrease bellow 4°C, the pump and the burner will start.

Содержание 24

Страница 1: ...80 60 maxi 8 24 kW 9 28 kW C H operating temperature 80 C max 80 C max C H circuit pressures Min operating 0 7 bar 0 7 bar C H circuit pressures Max operating 2 5 bar 2 5 barr Safety discharge 3 bar...

Страница 2: ...F GVO PVF PVO Pump head available Minimum flow rate with all heating thermostatic valves closed bar 0 1 3 4 1 2 3 4 5 6 8 11 12 13 14 17 7 15 10 9 16 1 Steel chassis complete with expansion vessel not...

Страница 3: ...e temperature when weather is cold press to reduce temperature when weather is fair During the temperature setting operation the display will flash If the room thermostat is calling for heat a dot wil...

Страница 4: ...ether and shut off the gas The red lockout indicator led 35 will light Press the reset button to re light the burner The central heating flow temperature is controlled by the central heating control t...

Страница 5: ...5 CENTORA GREEN FUNCTIONAL DIAGRAM 49 48 43 41 19 16 39 37 21 23 18 14 13 12 6 3 8 5 7 DIAGRAM ELECTRICAL WIRING...

Страница 6: ...de from 01 to 99 Menu 2 Boiler conditions Indicates the conditions or the configurations of the boiler Section Digit 1 Digit 2 and 3 Software version of display PCB 0 10 to 99 Flue type 2 1 FF variabl...

Страница 7: ...Pump post circulation duration 2 0 0 min From 0 to 5 minutes by step of 0 5 min 2 0 5 min 2 1 0 min 2 5 0 min Maximum Central Heating flow temperature 4 50 C 4 80 C CH anti cycling delay 8 0 0 min Fr...

Страница 8: ...ng on the combustion rate to maximum output set in menu 4 sec tion 9 Central heating temperature is dis played in celsius degrees The 3 dots indicate that the combus tion rate control is ON at maximum...

Страница 9: ...pump and burner change for section 9 Adjustment of CH heat output Press on key on Right side 9 times The display shows 906 which corresponds to the 18 kW which is the factory setting 9 section 9 06 18...

Страница 10: ...and the different transformers in the sealed chamber Check combustion chamber insulation panels for damage Check the lighting and ionisation electrodes condition Clean the burner Never use metallic br...

Страница 11: ...connection pipe onto the gas valve assembly Disconnect the connec tors from gas solenoids and fan Loosen the gas pipe nut Unscrew six nuts to release combustion chamber front panel and pull the assem...

Страница 12: ...rse order 21 Spark generator Carry out step 1 and 2 as above Unplug the connector from the spark generator located on the right hand side of the main heat exchanger Loosen the two screws to remove the...

Страница 13: ...minute if the error code 24 still display check the connection fan or replace the fan Yes Yes Yes Yes Yes No No No No Ok No Ok Replace heating thermistor Check heating thermistor Ok No No No No Yes Ye...

Страница 14: ...displayed Replace control PCB Replace display PCB or control the connection between the 2 PCBs No No Yes No No Does the orange LED light No Yes Yes Yes Yes No 3 Replace display PCB or control the conn...

Страница 15: ...10 T1 SW1 RL8 RL7A RL7 RL6 RL10 RL5A RL5 RL4A RL4 RL3A RL3 RL2A RL1A RL9 RL1 RAD1 R118 R114 R113 R111 R112 R110 R109 R108R107 R106 R9 R105 R101 R100 R99 R98 R97 R96 R8 R95 R94 R93 R92 R90 R88 R66 R65...

Страница 16: ...in this document Manufacturer Chaffoteaux Maury France Commercial subsidiary MTS GB Limited MTS Building Hughenden Avenue High Wycombe Bucks HP13 5FT Telephone 01494 755600 Fax 01494 459775 Internet...

Отзывы: