MAINTENANCE AND
SERVICE GUIDE
Fanned Flue Condensing Central
Heating System Boiler 24 and 30
Dimensions
Flue types:
C 13: C 33: C 53:
c
108 108
JL
N
I
88
J
L
N
232
235
32
380
212
360
50
67
8
5
0
7
3
7
Safety valve
center line
All dimensions in mm
Outer case dimensions :
- Width :
440 (minimum space required 450)
- Height :
850
- Depth :
380 (24kW) - 405 (30 kW)
212
360
67
737
850
50
I
Safety valve outlet
J Heating flow
L Gas supply
N Heating return
Technical Data
Heat gross input C/H maxi ............................
9.2-27.8 kW
10.4-31.6 kW
Heat output C/H 50°/30° maxi .......................
9-26 kW
10-30kW
Heat output C/H 80°/60° maxi .......................
8-24 kW
9-28 kW
C/H operating temperature............................
80°C max
80°C max
C/H circuit pressures Min operating ..............
0.7 bar
0.7 bar
C/H circuit pressures Max operating .............
2.5 bar
2.5 barr
Safety discharge ...........................................
3 bar
3 bar
Expansion vessel - Pre-charge pressure ......
0,7 bar
0.7 bar
Net capacity at 3 bar in liter...........................
5.44
5,44
Supply ...........................................................
230 v
230 v
Consumption .................................................
150 w
150 w
Protection ......................................................
IP 44
IP 44
Fuse F1/F2/F3/F4 .........................................
2 A/1.25 A/0.315 A/0.250 A
External controls ...........................................
24 v
24 v
Natural gas G20
Gas rate C/H max ................... 2.64 m
3
/h
3.01 m
3
/h
Gas rate C/H mini.................... 0.87 m
3
/h
1 m
3
/h
Gas valve restrictor diameter ..
without
without
Propane L.P.G G31
Gas rate C/H max. .................. 1.94 kg/h
2.21 kg/h
Gas rate C/H mini.................... 0.64 kg/h
0.73 kg/h
Gas valve restrictor diameter .. 4.40 mm
4.80 mm
24 kW
30 kW
24 kW
30 kW
24 : 380
30 : 405