SYS3316RF Installation Manual
Digit Position (4): Minutes - 1's
Digit Position (4): Minutes - 1's
Digit Position (4): Minutes - 1's
Digit Position (4): Minutes - 1's
Digit Position (4): Minutes - 1's
(1)
(2)
(3)
(4)
(5)
(6)
B
B
B
B
B
4
4
4
4
4
1
1
1
1
1 3
3
3
3
3 2
2
2
2
2 8
8
8
8
8 2
2
2
2
2 6
6
6
6
6
Example: If the time were 26 seconds past 1:28 pm, B4 would be programmed
HOUR
MINUTE SECOND
#
Digit Position (6): Seconds - 1's
Digit Position (6): Seconds - 1's
Digit Position (6): Seconds - 1's
Digit Position (6): Seconds - 1's
Digit Position (6): Seconds - 1's
Digit Position (3): Minutes - 10's
Digit Position (3): Minutes - 10's
Digit Position (3): Minutes - 10's
Digit Position (3): Minutes - 10's
Digit Position (3): Minutes - 10's
Digit Position (2): Hour - 1's
Digit Position (2): Hour - 1's
Digit Position (2): Hour - 1's
Digit Position (2): Hour - 1's
Digit Position (2): Hour - 1's
This command will set the hour, minute, and second in
the panel. The time is set in BCD (military time).
Previously stored data is not displayed during programming.
Command Location B4: Set Real-Time Clock (Hour, Minute, Second)
Command Location B4: Set Real-Time Clock (Hour, Minute, Second)
Command Location B4: Set Real-Time Clock (Hour, Minute, Second)
Command Location B4: Set Real-Time Clock (Hour, Minute, Second)
Command Location B4: Set Real-Time Clock (Hour, Minute, Second)
(2)
(3)
(4)
(5)
(1)
(6)
B
B
B
B
B
4
4
4
4
4
#
Digit Position (5): Seconds - 10's
Digit Position (5): Seconds - 10's
Digit Position (5): Seconds - 10's
Digit Position (5): Seconds - 10's
Digit Position (5): Seconds - 10's
Command Location B3: Set Real-Time Clock (Year, Month, Day)
Command Location B3: Set Real-Time Clock (Year, Month, Day)
Command Location B3: Set Real-Time Clock (Year, Month, Day)
Command Location B3: Set Real-Time Clock (Year, Month, Day)
Command Location B3: Set Real-Time Clock (Year, Month, Day)
This command will set the day, month, and year in the
panel, and will not take effect until Command B4 is
programmed.
(2)
(3)
(4)
(5)
(6)
B
B
B
B
B
3
3
3
3
3
(1)
#
Previously stored data is not displayed during programming.
Digit Position (1): Year - 10's
Digit Position (1): Year - 10's
Digit Position (1): Year - 10's
Digit Position (1): Year - 10's
Digit Position (1): Year - 10's
Digit Position (2): Year - 1's
Digit Position (2): Year - 1's
Digit Position (2): Year - 1's
Digit Position (2): Year - 1's
Digit Position (2): Year - 1's
Digit Position (3): Month - 10's
Digit Position (3): Month - 10's
Digit Position (3): Month - 10's
Digit Position (3): Month - 10's
Digit Position (3): Month - 10's
Digit Position (4): Month - 1's
Digit Position (4): Month - 1's
Digit Position (4): Month - 1's
Digit Position (4): Month - 1's
Digit Position (4): Month - 1's
Digit Position (5): Day - 10's
Digit Position (5): Day - 10's
Digit Position (5): Day - 10's
Digit Position (5): Day - 10's
Digit Position (5): Day - 10's
Digit Position (6): Day - 1's
Digit Position (6): Day - 1's
Digit Position (6): Day - 1's
Digit Position (6): Day - 1's
Digit Position (6): Day - 1's
(1)
(2)
(3)
(4)
(5)
(6)
B
B
B
B
B
3
3
3
3
3
9
9
9
9
9 5
5
5
5
5 0
0
0
0
0 4
4
4
4
4 1
1
1
1
1 2
2
2
2
2
Example: If the date were April 12, 1995, B3 would be programmed
YEAR
MONTH
DAY
#
Command Location A0: Test Report Countdown Timer
Command Location A0: Test Report Countdown Timer
Command Location A0: Test Report Countdown Timer
Command Location A0: Test Report Countdown Timer
Command Location A0: Test Report Countdown Timer
This command will set the time when the first Test Report is transmitted to the central
station. The panel will use this transmission time each time it's powered up or the CPU
is reset (unless Command Location A0 is reprogrammed).
Previously stored data is not displayed during programming.
(1)
A
A
A
A
A
0
0
0
0
0
#
Digit Position (1): Set Test Report Countdown Timer
Digit Position (1): Set Test Report Countdown Timer
Digit Position (1): Set Test Report Countdown Timer
Digit Position (1): Set Test Report Countdown Timer
Digit Position (1): Set Test Report Countdown Timer
NOTE: Refer to CL 2B for setting the
time interval between Reports.
0 = 1/4 hour
1 = 1/2 hour
2 = 1 hour
3 = 2 hours
4 = 3 hours
5 = 4 hours
6 = 6 hours
7 = 8 hours
8 = 10 hours
9 = 12 hours
0 = 14 hours
1 = 16 hours
2 = 18 hours
3 = 20 hours
4 = 22 hours
5 = 24 hours
Example: The time is 1500 hours (3:00 pm). You want the first Test Report to
transmit at 0100 hours (1:00 am). 3:00 pm + 10 hours = 1:00 am.
Program the value "8" in Memory Location A0.
CL A0,
CL A0,
CL A0,
CL A0,
CL A0, B3 and B4
B3 and B4
B3 and B4
B3 and B4
B3 and B4
Digit Position (1): Hour - 10's
Digit Position (1): Hour - 10's
Digit Position (1): Hour - 10's
Digit Position (1): Hour - 10's
Digit Position (1): Hour - 10's