18
18
18
18
18
SYS3316RF Installation Manual
Command Locations 30 - 3F: Loop Switches
Command Locations 30 - 3F: Loop Switches
Command Locations 30 - 3F: Loop Switches
Command Locations 30 - 3F: Loop Switches
Command Locations 30 - 3F: Loop Switches
(1)
(2)
(3)
(4)
0
1
0
0
Default Values
Default Values
Default Values
Default Values
Default Values
3
3
3
3
3
0
0
0
0
0
30 = Loop 1
31 = Loop 2
32 = Loop 3
33 = Loop 4
34 = Loop 5
35 = Loop 6
36 = Loop 7
37 = Loop 8
38 = Loop 9
39 = Loop 10
3A = Loop 11
3B = Loop 12
3C = Loop 13
3D = Loop 14
3E = Loop 15
3F = Loop 16
#
Digit Position (1): Enable Door Chime
Digit Position (1): Enable Door Chime
Digit Position (1): Enable Door Chime
Digit Position (1): Enable Door Chime
Digit Position (1): Enable Door Chime
0 = No
1 = Yes: keypads beep 2 seconds when faulted (disarmed condition)
Digit Position (2): Allow Shunting of This Loop
Digit Position (2): Allow Shunting of This Loop
Digit Position (2): Allow Shunting of This Loop
Digit Position (2): Allow Shunting of This Loop
Digit Position (2): Allow Shunting of This Loop
0 = No: makes it a priority zone (not shuntable)
1 = Yes: authorized users can bypass or force arm
Refer to CL 01 - 08 & 51 - 58 Digit Position (1) for
Arming Types (Authorization Levels)
Digit Position (3): Allow Group Shunting for This Loop
Digit Position (3): Allow Group Shunting for This Loop
Digit Position (3): Allow Group Shunting for This Loop
Digit Position (3): Allow Group Shunting for This Loop
Digit Position (3): Allow Group Shunting for This Loop
0 = No
1 = Yes: this loop will shunt with Group Shunt
Digit Position (4): Delay Before Dial
Digit Position (4): Delay Before Dial
Digit Position (4): Delay Before Dial
Digit Position (4): Delay Before Dial
Digit Position (4): Delay Before Dial
0 = No
1 = Yes: this loop will delay dialing on alarm for time programmed in 0B (1)
Command Location 48: Trouble Reports
Command Location 48: Trouble Reports
Command Location 48: Trouble Reports
Command Location 48: Trouble Reports
Command Location 48: Trouble Reports
(1)
(2)
(3)
(4)
F
1
E
1
Default Values
Default Values
Default Values
Default Values
Default Values
4
4
4
4
4
8
8
8
8
8
#
Digit Position (1): Trouble Report Code
Digit Position (1): Trouble Report Code
Digit Position (1): Trouble Report Code
Digit Position (1): Trouble Report Code
Digit Position (1): Trouble Report Code
This is a one-digit reporting code.
Program 0 to disable Trouble Report.
Digit Position (2): Trouble Report Receiver Select
Digit Position (2): Trouble Report Receiver Select
Digit Position (2): Trouble Report Receiver Select
Digit Position (2): Trouble Report Receiver Select
Digit Position (2): Trouble Report Receiver Select
0 = Receiver 1 with Receiver 2 as back-up
1 = Receiver 1 only
2 = Receiver 2 only
3 = Receiver 1 and Receiver 2 (Dual Reporting)
Digit Position (3): Trouble Restoral Report Code
Digit Position (3): Trouble Restoral Report Code
Digit Position (3): Trouble Restoral Report Code
Digit Position (3): Trouble Restoral Report Code
Digit Position (3): Trouble Restoral Report Code
This is a one-digit reporting code.
Program 0 to disable Trouble Restoral Report.
Digit Position (4): Trouble Restoral Report Receiver Select
Digit Position (4): Trouble Restoral Report Receiver Select
Digit Position (4): Trouble Restoral Report Receiver Select
Digit Position (4): Trouble Restoral Report Receiver Select
Digit Position (4): Trouble Restoral Report Receiver Select
0 = Receiver 1 with Receiver 2 as back-up
1 = Receiver 1 only
2 = Receiver 2 only
3 = Receiver 1 and Receiver 2 (Dual Reporting)
A
B
C
D
E
F
Hexadecimal Value
Hexadecimal Value
Hexadecimal Value
Hexadecimal Value
Hexadecimal Value
Key Strokes
Key Strokes
Key Strokes
Key Strokes
Key Strokes
0
1
2
3
4
5
PROGRAMMING CONVERSIONS
PROGRAMMING CONVERSIONS
PROGRAMMING CONVERSIONS
PROGRAMMING CONVERSIONS
PROGRAMMING CONVERSIONS
CL 30 - 3F & 48
CL 30 - 3F & 48
CL 30 - 3F & 48
CL 30 - 3F & 48
CL 30 - 3F & 48