16
16
16
16
16
SYS3316RF Installation Manual
Command Location 2C: Opening and Closing Report Codes
Command Location 2C: Opening and Closing Report Codes
Command Location 2C: Opening and Closing Report Codes
Command Location 2C: Opening and Closing Report Codes
Command Location 2C: Opening and Closing Report Codes
(1)
(2)
(3)
(4)
B
1
C
1
Default Values
Default Values
Default Values
Default Values
Default Values
2
2
2
2
2
C
C
C
C
C
Digit Position (1): Opening Report Code
Digit Position (1): Opening Report Code
Digit Position (1): Opening Report Code
Digit Position (1): Opening Report Code
Digit Position (1): Opening Report Code
#
Valid entries are 0 - F.
The User ID # is transmitted after the opening code.
Program 0 to disable Opening Reports.
Digit Position (2): Opening Report Receiver Select
Digit Position (2): Opening Report Receiver Select
Digit Position (2): Opening Report Receiver Select
Digit Position (2): Opening Report Receiver Select
Digit Position (2): Opening Report Receiver Select
0 = Receiver 1 with Receiver 2 as back-up
1 = Receiver 1 only
2 = Receiver 2 only
3 = Receiver 1 and Receiver 2 (Dual Reporting)
Digit Position (3): Closing Report Code
Digit Position (3): Closing Report Code
Digit Position (3): Closing Report Code
Digit Position (3): Closing Report Code
Digit Position (3): Closing Report Code
Valid entries are 0 - F.
The User ID # is transmitted after the opening code.
Program 0 to disable Closing Reports.
Digit Position (4): Closing Report Receiver Select
Digit Position (4): Closing Report Receiver Select
Digit Position (4): Closing Report Receiver Select
Digit Position (4): Closing Report Receiver Select
Digit Position (4): Closing Report Receiver Select
0 = Receiver 1 with Receiver 2 as back-up
1 = Receiver 1 only
2 = Receiver 2 only
3 = Receiver 1 and Receiver 2 (Dual Reporting)
Command Location 2D: Duress Report and Delays
Command Location 2D: Duress Report and Delays
Command Location 2D: Duress Report and Delays
Command Location 2D: Duress Report and Delays
Command Location 2D: Duress Report and Delays
Digit Position (4): Exit Delay Time
Digit Position (4): Exit Delay Time
Digit Position (4): Exit Delay Time
Digit Position (4): Exit Delay Time
Digit Position (4): Exit Delay Time
Default Values
Default Values
Default Values
Default Values
Default Values
(1)
(2)
(3)
(4)
(5)
1
3
6
2
0
2
2
2
2
2
D
D
D
D
D
Digit Position (1): Duress Report Code
Digit Position (1): Duress Report Code
Digit Position (1): Duress Report Code
Digit Position (1): Duress Report Code
Digit Position (1): Duress Report Code
#
Valid entries are 0 - F.
The User ID # will be reported as the second digit when reporting.
Program 0 to disable Duress Reports.
Digit Position (2): Duress Receiver Select
Digit Position (2): Duress Receiver Select
Digit Position (2): Duress Receiver Select
Digit Position (2): Duress Receiver Select
Digit Position (2): Duress Receiver Select
0 = Receiver 1 with Receiver 2 as back-up
1 = Receiver 1 only
2 = Receiver 2 only
3 = Receiver 1 and Receiver 2 (Dual Reporting)
Digit Position (3): Entry Delay Time
Digit Position (3): Entry Delay Time
Digit Position (3): Entry Delay Time
Digit Position (3): Entry Delay Time
Digit Position (3): Entry Delay Time
NOTE: To program delay times greater
than 150 secs, see CL 1F - 26 &
49 - 50 Digit Position (4)
1 = 110 secs
2 = 120 secs
3 = 130 secs
4 = 140 secs
5 = 150 secs
6 = 60 secs
7 = 70 secs
8 = 80 secs
9 = 90 secs
0 = 100 secs
1 = 10 secs
2 = 20 secs
3 = 30 secs
4 = 40 secs
5 = 50 secs
1 = 110 secs
2 = 120 secs
3 = 130 secs
4 = 140 secs
5 = 150 secs
6 = 60 secs
7 = 70 secs
8 = 80 secs
9 = 90 secs
0 = 100 secs
1 = 10 secs
2 = 20 secs
3 = 30 secs
4 = 40 secs
5 = 50 secs
Digit Position (5): Audible Time
Digit Position (5): Audible Time
Digit Position (5): Audible Time
Digit Position (5): Audible Time
Digit Position (5): Audible Time
1 = 2 min
2 = 5 min
3 = 10 min
4 = 15 min
5 = 30 min
A
B
C
D
E
F
Hexadecimal Value
Hexadecimal Value
Hexadecimal Value
Hexadecimal Value
Hexadecimal Value
Key Strokes
Key Strokes
Key Strokes
Key Strokes
Key Strokes
0
1
2
3
4
5
PROGRAMMING CONVERSIONS
PROGRAMMING CONVERSIONS
PROGRAMMING CONVERSIONS
PROGRAMMING CONVERSIONS
PROGRAMMING CONVERSIONS
CL 2C and 2D
CL 2C and 2D
CL 2C and 2D
CL 2C and 2D
CL 2C and 2D
NOTE: To program delay times greater
than 150 secs, see CL 1F - 26 &
49 - 50 Digit Position (4)