background image

 

 

 

 

Notices for use

 

Working principle and special functions for cooling

 

Principle:

 

Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that 

indoor ambient temperature decreased, its cooling capacity will increase or decrease by 

outdoor ambient temperature.

 

Anti-freezing function:

 

If the unit is running in COOL mode and in low temperature, there will be frost formed on 

the heat exchanger, when indoor heat exchanger temperature decreased below 0

, the 

indoor unit microcomputer will stop compressor running and protect the unit.

 

Working principle and special functions for heating

 

Principle:

 

Air conditioner absorbs heat from outdoor and transmits to indoor, in this way to increase 
room temperature. This is the heat pump heating principle, its heating capacity will be

 

reduced due to outdoor temperature decrease.

 

If outdoor temperature becomes very low, please operate with other heating equipments.

 

 

Defrosting:

 

When outdoor temperature is low but high humidity, after a long while running, frost will

 

form on outdoor unit, that will effect the heating effect, at this time, the auto defrosting 

function will act, the heat running will stop for 8-10mins.

 

*

 

During the auto defrosting, the fan motors of indoor unit and outdoor unit will stop.

 

During the defrosting, the indoor indicator flashes, the outdoor unit may emit  vapor.

 

This is due to the defrosting, it isn't malfunction.

 

After defrosting finished,the heating will recover automatically.

 

*

 

*

 

Anti-cool wind function:

 

In "Heat" mode, under the following three kinds of state, if indoor heat exchanger doesn't 
arrive at certain temp., indoor fan will not act, in order to prevent cool wind blowing(within

 

2 mins):

 

1. Heating starts.

 

2.After Auto Defrost finished.

 

3.Heating under the low temperature.

 

3

 

Содержание INVERTER SERIES

Страница 1: ...or selecting H air conditioners Please read this manual carefully before operation and keep it for further reference C H AIR CONDITIONERS Split Air Conditioner INVERTER SERIES MODELS CH S09FTXG CH S12...

Страница 2: ...eal one This appliance is not intended for use by persons including children with reduced physiced sensory or mental capabilities or lack of experience and knowledge unless they have been given superv...

Страница 3: ...e about 5 degree It can preclude the electricity wasted Don t leave windows and doors open for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block...

Страница 4: ...ong time It can cause the health problems Don t use the air conditioner for other purposes such as drying clothes preserving foods etc Splashing water on the air conditioner can cause an electric shoc...

Страница 5: ...capacity will be reduced due to outdoor temperature decrease If outdoor temperature becomes very low please operate with other heating equipments Defrosting When outdoor temperature is low but high hu...

Страница 6: ...utdoor sideDB WB o C Maximum cooling 32 23 48 Minimum cooling 21 15 10 Maximum heating 27 24 18 Minimum heating 20 15 Notices for use The operating temperature range outdoor temperature for cooling un...

Страница 7: ...ut The pattern in displayer Cool Dry Fan Heat Run Set temp Wireless remote control Air in Air out 5 Outdoor unit Indoor unit 1 Power cable 2 Remote control 3 Front panel 4 Filter 5 Guide louver 6 Wall...

Страница 8: ...ted circularly Auto mode is default while power on Under Auto mode the temperature will not be displayed Under Heat mode the initial value is 28 82 oF Under other modes the initial value is 25 77 o F...

Страница 9: ...e setting temperature if the users haven t set up temperature displaying status that will display the setting temperature This function is applicable to partial of models After powered on the setting...

Страница 10: ...umbers change in the one place of minute then the one place is constant ten numbers change in the tens place of minute at 2 5 seconds speed and carry During 5s blink press the Timer button the timer s...

Страница 11: ...on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould 1 Having set blow function on After turning off the unit by pressing ON OFF button indoor fan will continue running...

Страница 12: ...inished Operation of this function on or off If remote controller is under off status press mode button and blow button simultaneously in order to enter or cancel this new function If the unit is unde...

Страница 13: ...he front panel Clean the air filter Recommended once every three months NOTE If dust is much more around the air conditioner the air filters should be cleaned many times After taking off the filter do...

Страница 14: ...hether the installation stand of the outdoor unit is damaged or not If damaged please contact the dealer Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies Cle...

Страница 15: ...he smell accumulated in the ambient Solution method Cleaning the filter If problem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow...

Страница 16: ...nsert it Is it in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged...

Страница 17: ...e temperature of indoor heat exchanger is very low that will stop deliver air in order to prevent cool air Within 2min In HEAT mode when the outdoor temperature is low or high humidity there are much...