Troubleshooting 

CAUTION

 

Don't attempt to repair the air conditioner by yourself, it can cause an electric shock or

 

fire. Please check the following items before asking for repair, it can save your time and 
money.

 

not operate in approximately 3minutes to

 

Waiting

 

are very high, this phenomenon would

 

due to the changes of temperature.

 

13

 

Phenomenon

 

Troubleshooting

 

Not operate immediately when the air 
conditioner is restarted.

 

 

●  

Once the air conditioner is stopped, it will 

protect itself.

 

 

There's unusual smell blowing from the outlet 
after operation is started.

 

 

● 

The unit has no peculiar smell by itself. If has, 

that is due to the smell accumulated in the 
ambient.

 

● 

Solution method: Cleaning the filter.

 

If problem still has, so need to clean air 
conditioner. (Please contact with the authorized 
maintenance center.)

 

Sound of water flow can be heard during 

the operation.

 

 

● 

The air conditioner is started, when it is 

running the compressor started or stopped 
running, or the unit is stopped, sometimes 
there is swoosh or gurgle, the sound is due 
to refrigerant flowing they are not malfuncti- 
ons.

 

 

In COOL mode, sometimes the mist emitted 
from the air outlet vent.

 

 

● 

When the indoor temperature and humidity

 

 

happen. This is caused by the room air is 
swiftly cooled down. After running for a while, 
indoor temperature and humidity will fall 
down, the mist will die away.

 

 

Creaking noise can be heard when start or 
stop the unit.

 

 

● 

This is caused by the deformation of plastic

 

 

 

 

Содержание INVERTER SERIES

Страница 1: ...or selecting H air conditioners Please read this manual carefully before operation and keep it for further reference C H AIR CONDITIONERS Split Air Conditioner INVERTER SERIES MODELS CH S09FTXG CH S12...

Страница 2: ...eal one This appliance is not intended for use by persons including children with reduced physiced sensory or mental capabilities or lack of experience and knowledge unless they have been given superv...

Страница 3: ...e about 5 degree It can preclude the electricity wasted Don t leave windows and doors open for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block...

Страница 4: ...ong time It can cause the health problems Don t use the air conditioner for other purposes such as drying clothes preserving foods etc Splashing water on the air conditioner can cause an electric shoc...

Страница 5: ...capacity will be reduced due to outdoor temperature decrease If outdoor temperature becomes very low please operate with other heating equipments Defrosting When outdoor temperature is low but high hu...

Страница 6: ...utdoor sideDB WB o C Maximum cooling 32 23 48 Minimum cooling 21 15 10 Maximum heating 27 24 18 Minimum heating 20 15 Notices for use The operating temperature range outdoor temperature for cooling un...

Страница 7: ...ut The pattern in displayer Cool Dry Fan Heat Run Set temp Wireless remote control Air in Air out 5 Outdoor unit Indoor unit 1 Power cable 2 Remote control 3 Front panel 4 Filter 5 Guide louver 6 Wall...

Страница 8: ...ted circularly Auto mode is default while power on Under Auto mode the temperature will not be displayed Under Heat mode the initial value is 28 82 oF Under other modes the initial value is 25 77 o F...

Страница 9: ...e setting temperature if the users haven t set up temperature displaying status that will display the setting temperature This function is applicable to partial of models After powered on the setting...

Страница 10: ...umbers change in the one place of minute then the one place is constant ten numbers change in the tens place of minute at 2 5 seconds speed and carry During 5s blink press the Timer button the timer s...

Страница 11: ...on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould 1 Having set blow function on After turning off the unit by pressing ON OFF button indoor fan will continue running...

Страница 12: ...inished Operation of this function on or off If remote controller is under off status press mode button and blow button simultaneously in order to enter or cancel this new function If the unit is unde...

Страница 13: ...he front panel Clean the air filter Recommended once every three months NOTE If dust is much more around the air conditioner the air filters should be cleaned many times After taking off the filter do...

Страница 14: ...hether the installation stand of the outdoor unit is damaged or not If damaged please contact the dealer Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies Cle...

Страница 15: ...he smell accumulated in the ambient Solution method Cleaning the filter If problem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow...

Страница 16: ...nsert it Is it in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged...

Страница 17: ...e temperature of indoor heat exchanger is very low that will stop deliver air in order to prevent cool air Within 2min In HEAT mode when the outdoor temperature is low or high humidity there are much...

Отзывы: