C&H 120N Скачать руководство пользователя страница 5

2

1. Safety precaution

NOTE 

The speci

fi

ed cables shall be applied in the wiring. No external  

force may be applied to the terminal. Otherwise, wire cut and 

heating may occur and result in 

fi

re.

• 

2. Installation accessory

Don’t install at the place where cover with heavy oil, vapor or 

sulfureted gas, otherwise, this product would be deformed 

that would lead to system malfunction.

Select the installation location

Preparation before installation

1. Please con

fi

rm that all the following parts you have been supply.

1
2
3
4
5

3

2

M3.9*25 (For Mounting on the Wall)

M4X25 (For Mounting on switch box)

6
7

8

3

2

No.

Name

Qty.

Remarks

Wire controller

Installation and owner’s manual 

For Mounting on the Wall

Plastic screw bars

Screws

Wall plugs

For fixing on switch box

Optional

Screws

9

Screw

1

1

Battery

The connective wires group

1

1

1

M4X8(For Mounting the connective wire group)

Содержание 120N

Страница 1: ...ner s Manual WIRED REMOTE CONTROLLER MODEL 120N IMPORTANT NOTE Please read this manual carefully before installing or operating your wired remote controller Make sure to save this manual for future re...

Страница 2: ...vice of the wired controller please read this manual carefully before using the unit For convenience of future reference keep this manual after reading it All the pictures in this manual are for expla...

Страница 3: ...e LCD of the wired controller 7 Name of button on the wired controller 8 Preparatory operation 9 Operation 10 Timer functions 11 Weekly Timer 1 12 Weekly Timer 2 13 Fault alarm handing 14 Technical in...

Страница 4: ...is installation manual Imporper installation may lead to electric shock or fire Reinstallation must be performed by professionals NOTE Do not install the unit in a place vulnerable to leakage of flamm...

Страница 5: ...d that would lead to system malfunction Select the installation location Preparation before installation 1 Please confirm that all the following parts you have been supply 1 2 3 4 5 3 2 M3 9 25 For Mo...

Страница 6: ...e of high voltage above like 115V 220V 380V and don t wire this kind of wire in the said loop wiring clearance between configured tubes should be at the range of 12 20in 300 500mm or above 3 The Shiel...

Страница 7: ...Insert a slot screwdriver into the slots in the lower part of the wired controller 2 places and remove the upper part of the wire controller Fig 3 2 7in 19mm 3 3in 84mm 1 8in 46mm 2 3in 60mm 1 7in 44m...

Страница 8: ...ck cover on the 86 switch box and use one ST3 9 25 screw to fix to the wall 3 Fasten the back plate of the wired controller Back plate Screws ST3 9 25 Screw hole fixed on the wall useone ST3 9 25mm Sc...

Страница 9: ...orrected on the first time operation Batteries in the wire controller can time under power failure which ensure the time keep right When the power restores if the time displayed is not correct it mean...

Страница 10: ...7 3 Installation method Fig 3 6 5 Wire with the indoor unit Wiring hole switch box A B 1 7in 44mm 2 3in 60mm Wiring hole switch box Model A Model B A B HA HB 1 1 7in 44mm 2 3in 60mm...

Страница 11: ...he other side of the connecting cable to the remote control 4 core wire The connective wires group shielded wire some units Mainboard 4 core wire Adaptor board Display board The connection cable A X Y...

Страница 12: ...have polarity For some units the wired controller connects to the unit HA and HB ports through the HA and HB ports There is no polarity between HA and HB SeeFig 3 9 HA HB Indoor Unit Wired Controller...

Страница 13: ...HA and HB port on the controller There is no polarity between HA and HB SeeFig 3 10 For some units one wired controller can support multiple units a maximum of 16 units In this case the wired controll...

Страница 14: ...e time In group control there will be no error displayed on the wired controller SeeFig 3 11 3 Installation method Fig 3 12 Putty Putty Putty Trap Trap Trap HA HB HA HB HA HB Indoor Unit 2 Indoor Unit...

Страница 15: ...during installation Fig 3 13 All the pictures in this manual are for explanation purpose only Your wire controller may be slightly different The actual shape shall prevail 4 Specification Wiring spec...

Страница 16: ...nvenient to place the wires and install the device Room temperature display Weekly Timer Mode Choose Auto Cool Dry Heat Fan Fan speed Auto Low Med High speed Swing on some models Timer ON OFF Temp set...

Страница 17: ...perature display Relative humidity display HORIZONTAL SWING display Temperature display Lock display Follow me feature display Turbo feature display ECO feature display GEAR feature display SLEEP feat...

Страница 18: ...2 MODE button 3 FUNC button 4 SWING botton 5 ADJUST button 6 TIMER button 7 COPY button 8 POWER button 9 CONFIRM button 10 BACK botton 11 DAY OFF DELAY button 12 CHILD LOCK button 7 Name of button on...

Страница 19: ...e timer display will flash 1 2 3 4 The date setting is finished and the time setting is prepared after pressing Timer button or CONFIRM button or there is no pressing button in 10 seconds The setting...

Страница 20: ...the 46 F 8 heating function can only be set by remote control you can not choose this function by wired controller 8 degree heating function on some models When the heating mode is 50 F 10 C 60 F 16...

Страница 21: ...e Operation mode setting Heat mode is invalid for cool only type unit When the mode is selected as emergency heating or electric heating mode is displayed the fan speed is Auto The Sleep 8 degree heat...

Страница 22: ...on or turn off the keypad tone F C scale selection on some models Press the buttons and for 3 seconds will alternate the temperature display between the F C scale When stepless speed regulation is su...

Страница 23: ...SWING button to start up down swing function The mark appears Press it again to stop Swing function For the units with horizontal vertical swing features only Press the buttons and for 3 seconds to ac...

Страница 24: ...or 2 seconds the auto swing is activated The mark appears Press it again to stop some units Use Swing button to adjust the Up down airflow direction and start the auto swing function 2 Pressing the bu...

Страница 25: ...bo function is activated the mark appears Press the FUNC button to select whether the room temperature is detected at the indoor unit or the wire controller Follow me function indicator The select fun...

Страница 26: ...ime when the smart eye is turned off the smart eye icon goes out 3 Shutdown switch mode turn on self cleaning turn on 8 degree heating function will automatically cancel the smart eye function Filter...

Страница 27: ...mode the RH icon flashes press the up and down keys to adjust the humidity the setting range is OFF 35 85 adjusted with 5 humidity Exit humidity adjustment state after 5 seconds of inactivity 2 After...

Страница 28: ...the boot cooling mode press the function key to select the GEAR icon press the confirm key to enter the GEAR control mode and first display the current GEAR status 50 75 OFF can be switched by the up...

Страница 29: ...ode 3 Step 3 set the low temperature co open temperature or 41 59 F 5 15 C that is this function is invalid When the ambient temperature is 41 59 F 5 15 C when the ambient temperature is lower than th...

Страница 30: ...er operation starts after the time has passed Off timer Use this timer function to stop air conditioner operation The timer operates and air conditioner operation stops after the time has passed On an...

Страница 31: ...the Timer display is flashing Press the Confirm button again to finish the settings 3 ex Off timer set at 18 00 4 Press the button or to set the time After the time is set the timer will start or stop...

Страница 32: ...lect the 1 2 Press the Confirm button and the Clock display is flashing 3 Press the button or to set the time of On timer and then press the Confirm button to confirm the setting 4 5 Press the button...

Страница 33: ...ing Press the button or to select the day of the week and then press the Confirm button to confirm the setting 30 Press the Timer button to select the and then press the Confirm button to confirm Week...

Страница 34: ...Confirm button to confirm the setting NOTE The weekly timer setting can be returned to the previous step by pressing Back button The time of timer setting can be delete by pressing Day off botton The...

Страница 35: ...onditioner will turn on automatically until the time of On timer ON OFF ON OFF 8 00 12 00 14 00 17 00 10 00 ex If press the POWER button once and quickly at 10 00 the air conditioner will turn on at 1...

Страница 36: ...on to set the DAY OFF 3 5 To cancel Follow the same procedures as those for setup 4 ex The DAY OFF is set for Wednesday The DAY OFF can be setted for other days by repeating the steps 2 and 3 The mark...

Страница 37: ...ly be enabled in Weekly Timer 1 and Weekly Timer 2 DELAY function Copy out the setting in one day into the other day During the weekly timer press the Confirm button 1 A reservation made once can be c...

Страница 38: ...the day to copy to Press the Confirm button to confirm the settings Press the Back button to back to the weekly timer 5 Press the Copy button to confirm Other days can be copied by repeating step 4 a...

Страница 39: ...The setting time mode temperature and fan speed appear on the LCD Press CONFIRM to enter the setting time process Press or to select the day of the week and then press CONFIRM Weekly timer setting 1...

Страница 40: ...o set the operation mode then press CONFIRM Press or to set the time then press CONFIRM ex Tuesday time scale 1 IMPORTANT Up to 8 scheduled events can be set on one day Various events can be scheduled...

Страница 41: ...s can be set by repeating steps 3 through 7 8 Additional days in a one week period can be set by repeating steps 3 through 8 9 NOTE The weekly timer setting can be returned to the previous step by pre...

Страница 42: ...utomatically To start WEEKLY timer operation ex To cancel To set the DAY OFF for a holiday After setting the weekly timer press CONFIRM 1 2 The timer mode can also be canceled by changing the timer mo...

Страница 43: ...for setup 4 ex The DAY OFF is set for Wednesday Set the DAY OFF for other days by repeating the steps 2 and 3 Copy out the setting in one day into the other day In the weekly timer press CONFIRM 1 A s...

Страница 44: ...to confirm the settings Press BACK to revert to the weekly timer 5 Press COPY to confirm Other days can be copied by repeating steps 4 and 5 ex Copy the setting of Monday to Wednesday 6 7 8 Press or...

Страница 45: ...o delete The setting time mode temperature and fan speed appear on the LCD The setting time mode temperature and fan speed can be deleted by pressing the DEL day off Delete the time scale in one day D...

Страница 46: ...o the following procedures The error displayed on the wire controller are different from those on the unit If error code appears please check the Owner s And Installation Manual and SERVICE Manu al EM...

Страница 47: ...onditioning unit is off into the query function of temperature press or to select SP press Confirm to adjust the static pressure value When the air conditioning unit is switch machine Long press COPY...

Страница 48: ...ss Confirm to complete it When the air conditioning unit is off into the query function of temperature press or to select tF The compensation temperature Range 5 5 C Press Confirm into setting state p...

Страница 49: ...ect then press Confirm to complete it When the air conditioning unit is off into the query function of temperature press or to select tHI or tLo Press Confirm into setting state press or to select the...

Страница 50: ...press Confirm to complete it Two line controller address selection Restore factory Settings The code setting of the wire controller shall prevail The wire controller address setting Restore factory S...

Страница 51: ...ture are not set The compensation of body temperature is uncompensated COOL and HEAT single COOL mode is restored to COOL and HEAT model Restore the temperature range to the factory setting Remote rec...

Страница 52: ...0 and above Android 6 0 and above NOTE Wireless safety strategy Smart kit only support WPA PSK WPA2 PSK encryption and none encryption WPA PSK WPA2 PSK encryption is recommended SAFETY PRECAUTION Due...

Страница 53: ...t is necessary to do network configuration again Due to different network situation control process may return time out sometimes If this situation occurs the display between board and App may not be...

Страница 54: ...et Google Play Store Apple App Store search for NetHome Plus and find the NetHome Plus app Download and install it on your phone You can also download the app by scanning the QR code below Android iOS...

Страница 55: ...AP distribution network It is necessary to forget any other around network and make sure the Android or IOS device just connect to the Wireless Network you want to configure Make sure the Android or I...

Страница 56: ...53 Network configuration by Bluetooth scan Note Make sure the bluetooth of your mobile device is working Press Add Device Press Scan for nearby devices 1 2 16 Wireless control connection...

Страница 57: ...Wait smart devices to find then click to add it Select home Wi Fi enter the password 3 4 16 Wireless control connection 54...

Страница 58: ...Wait connecting to the network 5 6 Configuration Success you can modify the default name 16 Wireless control connection 55...

Страница 59: ...8 7 You can choose an existing name or customize a new name Bluetooth network configuration is successful now you can see the device in the list 16 Wireless control connection 56...

Страница 60: ...s authentication and it usually appears in public area such as hotels restaurants etc Please connect to a Wi Fi that does not require authentication It is recommended to use a Wireless Network name th...

Страница 61: ...this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with FCC radiation exposure limits set forth for...

Страница 62: ...ns However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determine...

Страница 63: ...p switch NTOE This feature is only available under cool mode This feature is for some models INDOOR UNIT MAIN BOARD SW2 1 SW2 2 SW2 2 dip switch to be ON turn on the breezeless SW2 2 dip switch to be...

Страница 64: ......

Страница 65: ......

Отзывы: