background image

Alexandrite Long Pulse Laser 755nm

GENTAL MAX PRO

YOU JUST CAN NOT COPYAN ORIGINAL.

COPYRIGHTS RESERVED.

Содержание GentleMax Pro

Страница 1: ...Alexandrite Long Pulse Laser 755nm GENTAL MAX PRO YOU JUST CAN NOT COPYAN ORIGINAL COPYRIGHTS RESERVED ...

Страница 2: ... 5 3 Operation procedure 5 4 Clinical step 5 5 Switch off 6 Routine maintenance 21 6 1 Preventive maintenance 6 2 Routine maintenance 6 3 Visual inspection 6 4 Instrument Cleaning 6 5 Emergency stop switch test 6 6 Replacement of insurance fuse 6 7 Replace the cooling water 6 8 Move and transport the machine 6 9 Warranty 6 10 Troubleshooting 7 Fault handling 25 7 1 Fault handling guide 8 Clinical ...

Страница 3: ...ce please reply with the real laser which may has differences at some details from the photo showed above 1 Caster 2 Handrail 3 Right panel 4 Monitor 5 Bracket 6 Fiber 7 Cooling tubes 8 Headpiece 9 Emergency 10 Key switch 11 Front panel 12 Finger switch to support and transport the equipment to move the equipment to operation by software to catch the headpiece to conduct laser energy to hold t the...

Страница 4: ...re the cooling liquid 14 Left panel 15 Cooling device port to connect a separate cooling device for skin 16 Handrail 17 Water tank to store the cooling water for laser chamber 18 Electric socket to plug in power supply 19 Foot pedal to connect a foot pedal 20 Cooling window 21 Castor ...

Страница 5: ...ndrite Long Pulse Laser 755nm GENTAL MAX PRO 1 2 Packing list Laser bodyX1 Headpiece with cold wind cooling spot size 6 18mm Electric cableX1 Foot switchX1 Water chanelX1 KeysX2 GogglesX1 Eye Glasses X1 3 32 ...

Страница 6: ...lified technicians or workers from Perfectlaser can repair of maintain the laser 5 The laser connects earth with a wire of yellow and green color photo A Fine earth connection is very important A Different regions may have a different style electric plug above photo only can be reference 2 2 Optical safety 1 Laser headpiece is of high energy output no look at directly without any protection 2 Ensu...

Страница 7: ...s and eye patch are well wearing 9 The remarkable area should plant a label plate Caution of Laser 2 3 Safety Labels 1 Product plate Displays the product name model no and serial no and voltage frequency input and the date of manufacture 2 3 ETL LISTED label Laser label 4 Invisible laser radiation avoid eye or skin exposure and the U S patents the product covered 6 32 ...

Страница 8: ...Alexandrite Long Pulse Laser 755nm GENTAL MAX PRO 5 Water tank label 6 Hot water label 7 Caution no remove the covers 8 Caution for Class 4 laser 7 32 ...

Страница 9: ...Alexandrite Long Pulse Laser 755nm GENTAL MAX PRO 8 32 9 10 11 3 Specifications 3 1 Machine specification ...

Страница 10: ...tional cold air cooler Interface Max Energy 100J 1064nm 60J 755nm Pulse width 10 100ms Pulse amount 1 5T Pulse interval 5 100ms Pulse frequency 0 25 0 5 1Hz 2Hz Power system Power supply part 3680 watts with double IGBT IGBT part Made in Japan Capacitance capacity 5000ufx8 40000uf In charge voltage 110V 220V AC Capacitance 10000ufx8 Laser board Lamp 100x176x10mm Made by UK Lamp amounts 2 pieces Ro...

Страница 11: ...nment Corrosive substances such as acids etc may damage the surface of the wires and electronic equipment Dust in the air should be kept to the minimum Metal particles have a corrosive effect on the electronic device 2 Temperature and humidity Working temperature 10 30 keep temperature 0 55 Working Relative Humidity max 80 Storage relative humidity Max 90 3 Atmospheric pressure 860hPA 1060hPA 4 En...

Страница 12: ...TAL MAX PRO 4 Assembling 4 1 Assembling 1 Fiber support arm installation 1 Find the fiber support arm Inset the arm 2 Fix arm tightly with screws 3 Adjust the angle and screw it 4 Hang up 5 Hang up 6 Put the headpiece into the socket 11 32 ...

Страница 13: ... screw 3 Prepare the finger switch and insert into the port 7 Fix fiber tightly with screw 8 Prepare the cooling tube and insert into the port 9 Insert into the port deeply 3 Add water 1 Find the water injection and open the overflow 2 Add water by water injection 3 Overflow has water flowing out then close them 4 Connect foot pedal and electric plug 12 32 ...

Страница 14: ...the machine will automatically lock the user interface and prompt Water is not circulating accompanied by sound of the buzzer c Water temperature monitoring Machine built in temperature monitoring sensor monitoring the temperature of the cooling water into the water circulation system The upper temperature limit is set to 50 If the cooling water temperature reaches the set limit the user interface...

Страница 15: ... affect the service life of the machine d Water quality monitoring Machine Built in cooling water quality monitoring module if the water is impurities and water quality is bad the machine will no longer monitor the water flow suggesting that water is not circulating It should replace the cooling water in this time e water level monitoring The machine has no built level monitoring module or device ...

Страница 16: ...agena sound the start device inside the machine will start the machine the user interface will light 5 1 2 Monitor operation guide 2 The main display of the machine is light enter the initialization interface In the same time variety of detection devices inside the machine run The following welcome page shows on the screen Figure 5 1 2 Figure 5 1 2 This is the first logo page Click anywhere of thi...

Страница 17: ...Alexandrite Long Pulse Laser 755nm GENTAL MAX PRO Figure 5 1 3 4 The below page shows the main operating page for parameters adjustment Figure 5 1 4 Figure 5 1 4 16 32 ...

Страница 18: ...ton for applications reference The page will show the page as below At this page the YAG Applications can be selected by Hair Removal Diffuse Redness Vascular Lesions and Facial Treatment Or press this back to the main page c Energy selection At this page the energy can be selected from 10 100 Joules 1J 1000mj 17 32 a ...

Страница 19: ...enter into the engineer mode by password To check clients information installed k Cold air blowing Pulse duration and Pulse interval selection The pulse duration and pulse interval can be selected by 0ms 50ms 100ms 500ms 1000ms If Pulse duration 1000ms and Pulse Interval 0ms it means the cold air is blowing the skin continually l The cooling liquid need to be replaced m Press red circle to simmer ...

Страница 20: ...he machine is installed complete 2 Make sure the water is full filled 3 Position the machine correctly beside the treatment table clean the treatment area 4 Start the machine 5 Enter the welcome page 6 Enter the Alex page 7 Set up the parameters as required 8 Press standby key to ready for treatment 9 Now the laser is ready to shoot 10 Get the headpiece ready on the treatment area 11 Step the peda...

Страница 21: ...yes and ware eye patch on 7 Press standby key to ready for treatment Note Testing skin area should be in the center of treatment area and the skin is in average status 8 Step the pedal the long pulse light will out and the testing is end 9 Observe the skin reaction and communicate with patients for feelings and then to adjust the parameters If the parameter is suitable then start the treatment 10 ...

Страница 22: ...e the operator or patient is at potential risk of electromagnetic and pulse optical radiation 6 2 Routine maintenance Warning This machine produces high voltage and pulse light energy radiation The instrument can only be repaired by authorized personnel of our company 6 3 Visual inspection Checking the external system weekly to ensure that no loose cable and system is not damaged the LCD panel in ...

Страница 23: ...ch year or the system can t specification or An error information occurred Authorized personnel of our company 6 5 Emergency stop switch test Detection methods boot according to the main interface when press the stop button the system immediately shut off the device Rotate in the direction shown by the arrow urgent stop switch button start equipment 6 6 Replacement of insurance fuse Steps 6 8 1 6 ...

Страница 24: ...rew the drain screw in the base of the machine turn on the water until it is completed 6 8 Move and transport the machine 6 8 1 Move the machine In medical practice it is easy to move the machine in the two rooms Use the installation at the top of the motor at the bottom of the handle knob to scroll wheel Before moving between two rooms remove the pedal and the power cord 6 8 2 Transport the machi...

Страница 25: ...Alexandrite Long Pulse Laser 755nm GENTAL MAX PRO 6 10 Troubleshooting Trouble shooting Guide 24 32 ...

Страница 26: ... authorized maintenance personnel Not pre boot Laser generator fail u re Contact the authorized maintenance personnel Power Failure Replace the power supply please contact the authorized maintenance personnel Control panel failu re Change control board please contact the authorized maintenance personnel Wavelength switching abnormal Switching motor failure Replace the motor please contact the auth...

Страница 27: ... contact the authorized maintenance personnel Water flow alarm Lack of water in the water tank The water tank filled with water With air in the waterway Confirm the vent plug for free vent plug Flow sensor dam aged please contact the authorized maintenance personnel Pump does not st art please contact the authorized maintenance personnel There are bent of waterway system please contact the authori...

Страница 28: ...Alexandrite Long Pulse Laser 755nm GENTAL MAX PRO 3 If you have other trouble please contact the maintenance department of the Beijing perfectlaser company 27 32 ...

Страница 29: ...igment and can effectively improve the skin condition and does not require the customer to cease to rest that is suitable for various parts of the pigmentation remove 1 The scope of application a Rejuvenation wrinkle improve skin laxity deep rejuvenation b Tattoo removal various colors of tattoo removal c Get rid of skin pigmented include hyper pigmentation freckles poikiloderma age spots melasma ...

Страница 30: ...stomer carefully previously received any form of skin rejuvenation hair removal or other optical treatments to determine whether he she fit the machine 2 Explain to the customer possible discomfort and limitations in use process reassure and customers unrealistic expectations 8 6 Operation note matters For the convenience of users this manual provides a parameter a default value The default value ...

Страница 31: ...the latter the effect is not obvious 8 6 4 Operation skills 1 For safety always use the lower energy no upper part of the bone for example the forehead temples and cheekbones etc 2 We will focus on the head close to the skin to ensure that the spot size and the scale corresponds to the value 3 Do not operate eye socket the part of around the eye should be stretch to the bones above and operate aga...

Страница 32: ...fter operation 11 Cold compress about 20 minutes 12 Moisturizing sunscreen 8 7 Other items 1 If after using native produced blisters or sores on the skin can use antibiotic ointment or burn ointment blotted out 2 After using the machine within one month Customers should use high expansion sunscreen and moisturizing skin care products for care 31 32 ...

Отзывы:

Похожие инструкции для GentleMax Pro