26
S/N
Troubles
Reasons
Solution
14
The alarm lamp on the front
panel is on
Over heat protection
Two much welding
current
Reduce the welding current output
Working time too
long
Reduce the duty cycle (work
intermittently)
Over-voltage
protection
Power supply
fluctuates
Using the stable power supply
Low-voltage
protection
Power supply
fluctuates
Using the stable power supply
Too many machines
using power supply
in the same time
Reduce the machines using power
supply in the same time
Over-current
protection
Unusual current in
the main circuit
Check and repair the main circuit and
drive Pr6