![Canary MultiMux Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/canary/multimux/multimux_user-manual_3843122006.webp)
Section 2
–
MultiMux Operation and Installation
6
2.2 Datalogger Connection
The MultiMux is connected to the CR10/CR10X Controller or MultiLogger Mux Terminal Board (or ML
MUX TB) using the screw terminals on the terminal board.
The screw terminal block located on the bottom of the terminal board has the
following connections:
The table below lists the connections for the screw terminal block.
If using the MultiSensor Interface with your CR10 or CR10X then connect from the 10-pin connector
(using the supplied cable) on the Interface to the screw terminals of the MultiMux in the following order:
Pin
Color
Connection
Description
1
Brown
1H
Low side of CH1
2
Red
1L
High side of CH1
3
Orange
2H
Low side of CH2
4
Yellow
2L
High side of CH2
5
Green
AG
Gage shield
6
Blue
12V
Power
7
Purple
G
Ground
8
Grey
EN
Enable
9
White
CLK
Clock
10
Black
Cable Shields
Cable Shield
The MultiSensor Interface does not support the 6-wire switching capability of the MultiMux so the 3H and
3L terminals are not connected.
TB
ML MUX TB
Connection
Description
Bendix
Mux Cable
(5 pair)
Mux Cable
(6 pair)
1H
1H
High side of CH1
A
White
Brown
1L
1L
Low side of CH1
B
White
’
s Black
Brown
’
s Black
2H
2H
High side of CH2
C
Red
Red
2L
2L
Low side of CH2
D
Red
’
s Black
Red
’
s Black
3H
NC
High side of CH3
White
3L
NC
Low side of CH3
White
’
s Black
AG
S
Gage shield
E
Blue & Blue
’
s Black
Blue & Blue
’
s Black
12V
12V
Power
F
Yellow
Yellow
G
GND
Ground
G
Yellow
’
s Black
Yellow
’
s Black
EN
EN
Enable
H
Green
Green
CLK
CLK
Clock
J
Green
’
s Black
Green
’
s Black
S
Cable Shield
K
Shield Wires from
White & Red Pair
plus Overall
Shield Wires from
Brown & Red Pair plus