Canarm Tri-Lite 3LMPEC Series
31
9
ELECTRICAL INSTALLATION
9.2 Running the Motor Wire
The Canarm Tri-Lite 3LMPEC series’ custom designed chassis makes for running the motor wire in an
incognito fashion. The motor wire slot on the top of the chassis allows the power wire to be ran through
(or affixed to the side) of the extension bar, then conveniently through the top plate of the chassis
and directly in to the motor electrical box. See diagram below.
9.3 Input Power Cable Wiring Schematics
IMPORTANT: Grounding of the incoming power on the motor is required.
NOTE:
Canarm suggests using a field supplied fused disconnect switch.
1 Phase Voltage
: 120V/3Ph, 230V/1Ph
3 Phase Voltage
: 230V/3Ph & 460V/3Ph
Motor wire can be ran
through the wire hole on the
chassis, then alongside or
within the extension tube.
See Controller Data Sheet:
6-Core Shielded Conductor
Black - Phase 1
White - Phase 2
Green - Ground
Black - Phase 1
Black - Phase 3
Green/Yellow - Ground
Black - Phase 2
Motor wire can be ran
through the wire hole on the
chassis, then alongside or
within the extension tube.
See Controller Data Sheet:
6-Core Shielded Conductor