background image

M-HAF18 - 

11/09/17

                                                                                                                                                                 Page 3 of 3

 

MAINTENANCE

 
 

These fans are used in a variety of applications and therefore maintenance schedules will vary.  In general no more than 1/

6

" of dirt 

build-up should occur on blade, motor and guard for proper fan operation and to prevent premature failure. The complete fan should 
be wiped down on a regular basis to maintain the high efficiency of the fan. Particular care should be taken to clean fan blades front 
and back, and  guards for better air moving performance. The motor should be kept clean to prevent overheating and premature failure.  
As with all mechanical equipment scheduled inspections should include checking that all hardware is secure and blade set screws are 
tight. We suggest as a minimum, that this be performed at the start and twice more every season.

!

WARNING:

 

MOTORS ARE EQUIPPED WITH AUTOMATIC OVERLOAD PROTECTION AND MAY RESTART WITHOUT 
WARNING. ALWAYS DISCONNECT FROM POWER BEFORE ATTEMPTING TO SERVICE.

Moving parts,
disconnect power 
before servicing.

WARNING: 

DO NOT PRESSURE WASH THE MOTOR.  THE MOTOR IS TOTALLY ENCLOSED, BUT IT IS NOT 
SEALED.

WARNING: 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE 
FOLLOWING:

A)  Use this unit only in the manner intended by the manufacturer.  If you have questions, contact 
the manufacturer.

B)  Before servicing or cleaning unit, switch power off at service panel and lock the service 
disconnecting means to prevent power from being switched on accidentally.  When the service 
disconnecting means cannot be locked, securely fasten a prominent warning device, such as a 
tag to the service panel.

CAUTION:  

TIE OFF THE EXCESS CORD SO THAT IT WILL NOT GET CUT IN THE FAN.

CANARM LTD. 

CANARM LTEE. 

 ARTHUR MANUFACTURING FACILITY

2157 PARKEDALE AVE. PO BOX 367 

2555 RUE BERNARD LEFEBVRE 

#7686 CONCESSION 16, RR4

BROCKVILLE, ONTARIO K6V 5V6 

LAVAL, QUEBEC  H7C 0A5 

ARTHUR, ONTARIO  N0G 1A0

TELEPHONE: (613) 342-5424 

TELEPHONE:  (450) 665-2535 

TELEPHONE:  (519) 848-3910

FAX: 1-800-263-4598 

FAX:  (450) 665-0910 

 

FAX:  (519) 848-3948

E-MAIL: [email protected] 

E-MAIL: [email protected] 

E-MAIL: [email protected]

WARNING: 

ALL WIRING SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN FOLLOWING LOCAL CODES 
AND REGULATIONS.

USE & CARE

Fan Controls:

The fan comes complete with a 115V cord & plug.  A suitable outlet needs to be located in a suitable location near the fan.

WARNING: 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID 
STATE SPEED CONTROL DEVICE.

Содержание HAF18

Страница 1: ...aired or replaced are warranted through the remainder of the original warranty period only This warranty applies to the original purchaser user only it is null and void in case of alteration accident abuse neglect and operation not in accordance with instructions NOTICE No warranty claims will be honored by Canarm Ltd unless prior authorization is obtained Installation or Product problems Do not r...

Страница 2: ...LD RESULT IN SERIOUS INJURY WARNING THE LOWEST PART OF THE FAN MUST BE AT LEAST 3 METERS 10 FT ABOVE THE FLOOR READ INSTRUCTIONS COMPLETELY BEFORE INSTALLATION SAVE FOR REFERENCE M HAF18 04 13 16 Page 3 of 3 MAINTENANCE These fans are used in a variety of applications and therefore maintenance schedules will vary In general no more than 1 16 of dirt build up should occur on blade motor and guard f...

Страница 3: ...SK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer B Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked se...

Страница 4: ...e démontage et la réinstallation de l unité sur le site de l usager Les pièces qui seront changées ou remplacées seront garanties pour la durée de la garantie originale seulement Cette garantie s applique à l acheteur original seulement La garantie sera annulée dans le cas d altérations d abus de négligence ou si l appareil n a pas été utilisé selon le mode d emploi Problèmes d Installation ou que...

Страница 5: ...DU VENTILATEUR MISE EN GARDE NE PAS SERREZ FERMEMENT LES BOULONS ET LES ÉCROUS PEUT RÉSULTER EN BLESSURES GRAVES MISE EN GARDE LA PARTIE LA PLUS BASSE DU PLAFOND DOIT ÊTRE À AU MOINS 3 MÈTRES 10 PIEDS DU SOL LISEZ CE MODE D EMPLOI EN ENTIER AVANT DE PROCÉDER À L INSTALLATION ET GARDEZ LE POUR UNE RÉFÉRENCE ULTÉRIEURE M HAF18FR 04 13 16 Page 3 de 3 ENTRETIEN Ces ventilateurs sont utilisés dans une ...

Страница 6: ...ALEMENT FERMÉ MAIS N EST PAS SCELLÉ ATTENTION LIEZ L EXCÈS DU CORDON AFIN QU IL NE SOIT PAS ENTRAÎNÉ DANS LA ROTATION DU VENTILATEUR MISE EN GARDE AFIN DE RÉDUIRE LE RISQUE D INCENDIE DE SECOUSSE ÉLECTRIQUE OU DE BLESSURE VEUILLEZ SUIVRE LES CONSEILS SUIVANTS A Utilisez cet appareil de la façon qu il a été conçu par le manufacturier Si vous avez des questions communiquez avec le manufacturier B Av...

Отзывы: