Installation: Electrical power requirements
C.)
3-Phase 5 wires (live 1, live 2, live 3, neutral, ground)]
400VAC, 50/60Hz*, 3þ, 16A, (
Circuit Breaker rating = 20A max each phase line.)
In 3x16A Service:
Pump 2 is on one service.
The Heater is on another service.
Everything else is on the remaining service.
For 3-phase connection:
1.Completely remove jumper on J51 and J88.
2.Completely remove jumper on J52 and J62.
3. Make a connection between jumper J60 andJ45
4. Make a connection between jumper J41 and J79
5. Put DIP switches A2 and A3 on ON and DIP switch A5 on OFF.
B.)
2 x Single Phase
(live 1, neutral 1, live 2, neutral 2, ground)]
230VAC, 50/60Hz, 2þ, 16A,
(Circuit Breaker rating = 20A max each phase line.)
In 2x16A Service:
Pump 2 (if any) and the Heater are on one service.
Everything else is on the other service.
For 2-Wire connection:
1.Completely remove jumper on J51 and J88.
2.Completely remove jumper on J52 and J62.
3. Make a connection between jumper J60 andJ36
4. Make a connection between jumper J41 and J12
5. Make a connection between jumper J46 and J75
6. Make a connection between jumper J20 and J77
7. Make a connection between jumper J38 and J54
8. Put DIP switches A2, A3 and A5 on ON
POWERING UP YOUR SPA
Once the spa is properly wired and filled with water, the spa power can
be turned on and Start-up chemicals added.
1. Turn on RCD breaker. If breaker trips immediately check
Neutral and Ground Wire connections. Upon initial power up,
4 sets of numbers flash on the LED display of the topside
Console. The last number in the sequence is the incoming
power meter which can be used to verify that the spa is wired
correctly.
2. The spa begins an automatic priming routine which will last 6
minutes (
“Pr”
is on the LED display).
3. The priming routine will automatically run each spa pump to
prime. When the
“Pr”
is displayed, press any PUMP button
to prime that pump or wait for the priming routine to turn
on the Pump.
IMPORTANT:
To avoid pump damage, do not run
pumps for more than 1 minute without moving water. If no water
is moving, turn the power off and perform air lock procedure.
4. The Topside Console display flashes
“38C/100F”
then press
“--C/F”
for approximately 2 minutes to determine water
temperature as it flows through the heater.
5. The default pre-set temperature is 36.5°C. The last measured
temperature is constantly displayed on the LCD readout. This
temperature will be current only when the pump has been
running for at least 2 minutes. Set the desired temperature
between 26- 40°C (80-104°F) by pressing the temp button(s).
If the water temperature is below the set temperature, the spa’s
heater and heat indicator light will turn on. All features of
the Topside Console will be available. The spa will heat
approximately 1° every 30 minutes per 1,000 litres.
6. Check for leaks! Although spas are fully checked at the factory,
shipping & delivery might cause a leak. Remember to pay
particular attention to barrel unions adjoining the heater.
Contact your Canadian Spa dealer directly if there is a problem.
If your new spa pump does not prime (flow) on the initial start-up you
may be experiencing an “air lock”.
This normal occurrence can be easily corrected by loosening the
plumbing union on the suction side of the Jet or Pump until water
flows into the pump and all air is expelled.
PRESS BUTTONS SLOWLY FOR FIRST RUN WHEN STARTING UP
ONCE PR EXITS, SET TEMPERATURE ON SPA (SEE SPA OPERATION
SECTION FOR DIFFERENT SPA TOPSIDES)
ATTACHING YOUR SPA COVER
The Spa Cover is an important accessory to help preserve the spa’s temperature. The Spa Cover
also serves as a safety device, preventing unauthorised users from entering the spa. Proper
installation of the Spa Cover is an important addition in the spa installation.
1) Remove Spa Cover from packaging. 2) Place Spa Cover on spa in order to allow easy
access to the topside console when opening the cover.
3) Line up attaching straps and secure with mounting hardware and use locking mechanism
to lock Spa Cover in place.
IMPORTANT:
Always lock Spa Cover in place when not using the spa. Do not walk or sit on Spa Cover.
Remove snow build-up to avoid breaking the foam inner core. Do not drag Spa Cover on
rough surfaces.
BOTTOM MOUNT HOT TUB COVER LIFTER.
Fully compatible with Canadian Spas; this Cover Lifter is the ideal choice to
complement your hot tub or spa, making cover removal and replacement a quick,
one-handed operation while reducing wear and tear on your hot tub cover.
• Mounts directly to the spa
• Made of black powder-coated Aluminum
• Requires 31cm - 46 cm rear clearance
TOP MOUNT HOT TUB COVER LIFTER
Fully compatible with ALL our Canadian Spa hot tubs and spas and most other
brands; this Cover Lifter is the ideal choice to complement your Hot Tub, making
cover removal and replacement a quick, one-handed operation and reducing
wear and tear.
• Low-profile design
• Virtually zero clearance required behind spa – great for tight spaces
(particularly if your spa is located in a gazebo)
• Mounts directly to the spa
• Fits up to 2.4m Spas
• Made of Aluminium
LED LIGHTING
Change the colour of your spa with a press of a button, 13 colour options to
choose from. Chromatherapy is a great way to relax in your spa using colours to
change your mood.
How your spa functions
OZONE
MIXING
CHAMBER
T VALVE
T
VALVE
HEATER
CONTROL
PUMP
OZONE
LINE
MAZZEI INJECTOR
CHECK
VALVE
DRAIN
VALVE
AO
³
P
UV SYSTEM
PRE-FILTER
REMOVES
Debris
ANTI-BACTERIAL FILTERS
INHIBITS BACTERIAL
GROWTH
AO
3
P
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3