background image

L O N D O N   T P 5 0 0

L O N D O N   T P 5 0 0

(7)

(6)

Pre-Delivery Information

Before delivery check your spa 

height and width and add 5cm 

clearance on each side to ensure 

access.

X

Check that the hot tub can 

clear a 90

°

 turn

Rotary Isolation Switch 

(pictured). Make sure you have 

a qualified electrician prepare 

the electrics. Allow 5 metre 

slack to connect to Spa.

Ensure you have prepared 

a level concrete base or a 

properly fitted existing patio or 

decking with access to a drain.

Access:

 Canadian Spa hot tubs are usually delivered on a flat 

bed trailer, up to 5 metres long, 2.4 metres wide and 3.5 

metres high. Please ensure that there is adequate access for 

such a vehicle to reach your property. When off loading from 

our vehicle to the spa site, a minimum of 1100mm width is 

required, (some models vary) this also needs to be flat and a 

minimum clear vertical height of 9ft should be considered also. 

Electrical supply: 

If you are having your spa installed, it will 

be necessary to have a dedicated electrical circuit supply 

fitted. You will require up to 32 Amp (type C Breaker) supply, 

dependent on the length from the service point. Your spa must 

be protected via a RCD and suitable over current protection. 

A minimum of 5 metres of cable is required for connection into 

your spa from the Isolator.

Electrical installation:

  Arrange for a licensed electrician run 

the required 230-volt power line to the spa installation site. 

This power line must be permanently connected (hard-wired) 

to the mains supply. Do not use extension cords or plug-in type 

connections. At the site where the spa is to be located leave 5 

metres of cable and the appropriate cable gland. All electrical 

wiring to a spa must be installed by a qualified, licensed 

electrician, and meet required electrical standards.

Water: 

The best means of filling your spa is with a garden 

hosepipe (use cold water not hot water). Please ensure that 

you have one readily available. If you are aware that your water 

pressure is poor, we should be advised prior to delivery. The 

design of our spas allows for easy drainage, again, using the 

hosepipe which conveniently fits onto the drain valve situated 

at the base of your spa. Ideally, you should empty the water to 

a nearby drain. You may wish to purchase a suitable 

submersible pump to speed up this process. 

Decking around your spa:

 Ensure that you are aware of the 

above measurements. Always consider during your planning 

that any decking boards and supporting beams that you install 

allow access to the sides of your Spa. It is the customers’ 

responsibility to ensure that any decking is clear of these areas 

prior to any visit by our technicians (Allow 1 metre clearance 

around your hot tub and if you have decking ensure part of 

your decking can be removed in order to gain access for future 

repair or servicing). If you are unsure then please ask before 

ground construction and the delivery of your spa. 

Your spa must be sited on a solid, flat, level base which is the 

same size or larger than the spa. The base can be either a 

10-15cm concrete slab or suitably strengthened timber 

decking or existing patio area assuming it has suitable 

foundations of hardcore. Whatever base area is chosen, it must 

be of suitable load bearing capacity. Please ensure your base 

has suitable drainage.

NOTE: A 10-15 cm concrete base is ideal preparation for a hot tub.

Ensure part of your decking can be removed in order to gain access for future 

repair or servicing

Optional CraneService is available

 

How to change the Black Ice UV Lamp & Tube

To replace UV Light Lamp Only

Remove pressure fit end and replace Lamp. The end of the Lamp has 4 pins that fit 

into 4 pin plug, there will be no water as the clear quartz tube is sealed in UV 

Chamber, replace end and put back in and turn on valves. 

UV Light Water Treatment System

• Input Voltage: AC 230V 50/60 HZ

• Operating Current: 100mA

• Power: 15W

• Purification of water: 15L / Minute

• UV Lamp Lifetime 6000-8000 Hr

• Replace UV Lamp Annually 

c a n a d i a n s p a c o m p a n y . c o m

Spa Status LED (Optional)

 

Our new Spa Status LED provides convenience, right at your finger tips. Check the 

status of your spa by looking at the colour of the LED light from afar – no more 
breaking your back trying to remove your cover just to see if your spa is running!

NORMAL

OPERATION

REMINDER

NOTIFICATIONS

NEEDS 

ASSISTANCE

To replace UV Quartz Glass Tube & UV Light Lamp.

 

Follow UV Lamp replacement but before installing new UV Lamp unscrew end off UV 

Chamber and you will find a Quartz glass tube and a ‘O’ ring - replace tube and put ‘O’ 

ring near the top of the Tube, insert into chamber and screw back metal end, then install 

new UV Lamp. (Make sure to use gloves).

IMPORTANT: 

1) Turn off the power. 

2) Allow the UV Lamp to cool before replacing. 

3) Do not look at lit Lamps to avoid eye damage.

Step 1:

 Turn both red vales off horizontal position 

(as photos below) to isolate the UV Silver chamber. 

UV Quartz Glass Tube & 

‘O’ ring

UV 15w Lamp & Gloves 

Black Ice UV Kit

 

KK-11216

Step 1:

 Unscrew the 2 

red-marked screws.

Step 2:

 Remove the red lid

Step 3:

 Unplug this white 

connector

Step 4:

 Take out this black 

protective sleeve

Step 5:

 Pull out the Lamp to 

change it

Step 6:

 Put the Lamp inside 

the metal tube and cover it 

with black protective sleeve

Step 7:

 Plug in the white 

connector

Step 8:

 Cover the red lid and 

install these 2 screws

How to change Canadian Spa Wave Zone Lamp

IMPORTANT: 

1) Turn off the power. 2) Allow the UV Lamp to cool before replacing. 

3) Do not look at a lit UV Lamp to avoid eye damage.

Wave Zone UV Lamp Kit

 

KK-11202

 

The Advanced Oxidation Process is used 

in Canadian Spa Company's Hot Tubs. 

Combining our Ozone Generator with Ultra 

Violet Light creates a unique bacteria 

fighting superhero: Super Hydroxyl 

Radicals. They easily overcome even the 

most powerful of bacteria.

Turn both red vales off horizontal position 

(see photos opposite) to SHUT OFF the 

water and isolate the UV chamber. 

ON

OFF

Содержание London UV Spa KH-10131

Страница 1: ...L O N D O N T P 5 0 0 London UV Spa Owners Manual TP500 213 x 213 x 89cm 84 x 84 x 35 KH 10131 For Service Support please contact us anytime support canadianspacompany com canadianspacompany com...

Страница 2: ...will result in voiding the manufacturer s warranty 16 Do not bring any object into the spa that could damage the spa shell 17 Never insert any object into any opening 18 WARNING Do not sit on the spa...

Страница 3: ...LDERS x 2 Placeholder for drinking receptacle 7 AIR VALVE To adjust air flow into water stream 8 JET VARIOUS Device that ejects air and water creating water movement in the spa Adjustable directional...

Страница 4: ...ore ground construction and the delivery of your spa Your spa must be sited on a solid flat level base which is the same size or larger than the spa The base can be either a 10 15cm concrete slab or s...

Страница 5: ...are adhered to A Single Phase connection Most common CONNECTING HOT TUB TO RCD AND CONSUMER PANEL All hot tubs must be wired with the appropriate sized wiring Failure to do so will cause equipment da...

Страница 6: ...ailable The spa will heat approximately 1 every 30 minutes per 1 000 litres 6 Check for leaks Although spas are fully checked at the factory shipping delivery might cause a leak Remember to pay partic...

Страница 7: ...ssing noise Once water comes out tighten the valve back up pump has been bled of the trapped air Chlorine Granules Disinfection To protect your health ensure that your spa water is disinfected thoroug...

Страница 8: ...ild up B suspended particles C pH high D total alkalinity too high E poor filtration F high dissolved solids Debris in water High concentration of oils and organic contaminants being agitated by jet H...

Страница 9: ...failure Perform elimination test to determine failed component See elimination test section Heater not operating or spa not heating Temperature set to low Set temperature above current water temperatu...

Страница 10: ...the pump off and on will help it to prime Do not do this more than 5 times If the pump will not prime shut off the power to the spa and call for service Important A pump should not be allowed to run...

Страница 11: ...spa started at noon the filter cycles will run as programmed Flip Invert Display Restricting Operation The control can be restricted to prevent unwanted use or temperature adjustments Locking the pan...

Страница 12: ...Mode will last for 1 hour unless the mode is exited manually Drain Mode Some spas have a special feature that allows a pump to be employed when draining the water When available this feature is a com...

Страница 13: ...heater to start it The spa is shut down for 15 min Press any button to reset the heater start up See Flow Related Checks below Heater is Dry MO27 There is not enough water in the heater to start it T...

Страница 14: ...nder e g 7 days can be specified by the Manufacturer Press a Temperature button to reset a displayed reminder message Alternates with temperature or normal display Appears on a regular schedule e g ev...

Страница 15: ...nance or protection is essential Canadian Spa Co warrants the cover for the period of two 2 years Defects caused by misuse or insufficient care are not covered by the warranty TERMS CONDITIONS AND LIM...