EN-Rev IM-FDM-EN/1.6 Copyright © March 2017. Canadian Solar Inc.

10 | 

Table 1: 
Mechanical and Electrical Ratings under STC

Standard Test Conditions are: irradiance of 1 kW/m

2

air mass (AM) spectrum of 1.5, and cell temperature 
of 25°C. The electrical characteristics are respectively 

within ±10 percent or [0; +5 W] of the indicated valu-
es for Isc, Voc and Pmax. Specifications are subject 
to change without notice. 

Module Type

Maximum 

Power

Pmax <W>

Operating

voltage

Vmp <V>

Operating

current

Imp <A>

Open Cir-

cuit Voltage

Voc <V>

Short Circuit 

Current

Isc <A>

Max. Series

Fuse 

Rating <A>

Overall

Dimension

<mm>

Weight

<kg>

CS6K-245P-FG

245

30.0

8.17

37.1

8.74

15

1658ˣ 992 

ˣ 5.8

(65.3 ˣ 39.1 

ˣ 0.23 in)

without 

junction-

box and 

corner 

protector

23

CS6K-250P-FG

250

30.1

8.30

37.2

8.87

CS6K-255P FG

255

30.2

8.43

37.4

9.00

CS6K-260P-FG

260

30.4 

8.56 

37.5 

9.12 

CS6K-265P-FG

265

30.6 

8.66 

37.7 

9.23 

CS6K-270P-FG

270

30.8 

8.75 

37.9 

9.32 

CS6K-275P-FG

275

31.0 

8.88 

38.0 

9.45 

CS6K-280P-FG

280

31.3 

8.95 

38.2 

9.52 

CS6K-285P-FG

285

31.4

9.06

38.3

9.64

CS6K-290P-FG

290

31.6

9.18

38.5

9.72

CS6K-295P-FG

295

31.8

9.28

38.6

9.81

CS6K-300P-FG

300

32.0

9.38

38.8

9.92

CS6K-245M-FG

245

30.3

8.09

37.4

8.61

15

1658ˣ 992 

ˣ 5.8

(65.3 ˣ 39.1 ˣ 

0.23 in)

without 

junction-box 

and corner 

protector

23

CS6K-250M-FG

250

30.4

8.22

37.5

8.74

CS6K-255M-FG

255

30.5

8.35

37.7

8.87

CS6K-260M-FG

260

30.7

8.48

37.8

8.99

CS6K-265M-FG

265

30.9

8.61

37.9

9.11

CS6K-270M-FG

270

31.1

8.67

38.2

9.19

CS6K-275M-FG

275

31.3

8.80

38.3

9.31

cleaning effect). If the module has become soiled, 
it shall be washed with water and a non-abrasive 
cleaning implement (sponge) during the cool part 
of the day. 

Do not 

scrape or rub dry dirt away, as 

this may cause micro scratches.

·  Snow should be removed using a soft brush.

·  The system shall be periodically inspected to verify 

the integrity of all wiring and supports.

·  To protect against electric shock or injury, electrical 

or mechanical inspections and maintenance 

should be performed by qualified personnel only 

and on a regular basis.

·  Please refer to our Installation Manual Annex 

(Section Annex D: Module Cleaning Guideline) for 

more information on module cleaning.

AMENDED EDITIONS

AND DATES

· Rev 1.0 is released in June 2015
· Rev 1.1 is released in Aug. 2015.
· Rev 1.2 is released in January 2016.
· Rev 1.3 is released in May 2016.
· Rev 1.4 is released in June 2016. 
· Rev 1.5 is released in July 2016.
· Rev 1.6 is released in March 2017.

ANNEX A: 

MECHANICAL AND ELECTRICAL RATINGS  

Содержание Dymond CS6K-245P-FG

Страница 1: ...INSTALLATION MANUAL OF DYMOND MODULE For professional use only...

Страница 2: ...EN Rev IM FDM EN 1 6 Copyright March 2017 Canadian Solar Inc...

Страница 3: ...3 0 MECHANICAL ELECTRICAL SPECIFICATIONS 4 0 UNPACKING AND STORAGE 5 0 MODULE INSTALLATION 5 1 MODULE WIRING 5 2 MODULE GROUNDING 6 0 MOUNTING INSTRUCTIONS 7 0 MAINTENANCE AMENDED EDITIONS AND DATES...

Страница 4: ...cluding without limitation bodily harm injury or damage to property in connection with handling PV modules system installation or compliance or non compliance with the instructions set forth in this m...

Страница 5: ...rical Ratings Main electrical charac teristics under STC are also stated on each module label The maximum system voltage for double glass module type is 1000V UL and 1500V IEC Under certain conditions...

Страница 6: ...heavy loads may cause severe micro cracks at cell level which in turn may compromise module reliability Failure to comply with the above caution will void Canadian Solar Inc s warranty SYSTEM FIRE RA...

Страница 7: ...ing Only modules with similar electrical outputs should be connected in the same series to avoid or minimize mismatch effects in arrays To minimize risk in the event of an indirect light ning strike a...

Страница 8: ...ting system using UV resistant cable ties Protect exposed cables from damage by taking appropriate precautions e g placing them inside a plastic conduit Avoid exposure to direct sunlight A minimum ben...

Страница 9: ...overlap the module by 13 mm to 15 mm 5 To ensure the thickness of the clamps is at least 3 mm Clamp positions are of crucial importance for the reliability of the installation the clamp centerline mu...

Страница 10: ...8 8 9 92 CS6K 245M FG 245 30 3 8 09 37 4 8 61 15 1658 992 5 8 65 3 39 1 0 23 in without junction box and corner protector 23 CS6K 250M FG 250 30 4 8 22 37 5 8 74 CS6K 255M FG 255 30 5 8 35 37 7 8 87 C...

Страница 11: ...305 32 7 9 33 39 9 9 91 CS6K 310MS FG 310 32 9 9 43 40 1 9 99 CS6X 290P FG 290 35 9 8 08 44 4 8 64 15 1968 992 5 8mm 77 5 39 1 0 23 in without junction box and corner protector 27 5 CS6X 295P FG 295 3...

Страница 12: ...A Clamping on module long side four clamp points Mounting rails must run perpendicularly to the module long side Clamping Location Illustration Illustration A Clamping on module long side six clamp p...

Страница 13: ...mp length 100 mm four clamps A 380 20 mm see illustration A Downforce load 2400 Pa Uplift load 2400 Pa VDE CSA 2 C 2 Profi clamp wide 3 8 mm clamp length 200 mm four clamps A 380 20 mm see illustratio...

Страница 14: ...ngth 100 mm six clamps A 250 20 mm B 579 20 smm see illustration B Downforce load 5400 Pa Uplift load 2400 Pa VDE CSA 2 F 1 Akcome Metals Technology Suzhou Co Ltd AK EC DG End clamp AK MC DG Middle cl...

Страница 15: ...i clamp wide 3 8 mm clamp length 130 mm four clamps A 440 20 mm see illustration A Downforce load 2400 Pa Uplift load 2400 Pa VDE CSA 3 C 2 Profi clamp wide 3 8 mm clamp length 250 mm four clamps A 44...

Страница 16: ...1 End clamp PW CS 02 Middle clamp clamp length 100 mm six clamps A 300 20 mm B 684 20 mm see illustration B Downforce load 2400 Pa Uplift load 2400 Pa VDE CSA 3 E 4 PW CS 01 End clamp PW CS 02 Middle...

Отзывы: