Canadian Solar Inc. recommends mounting rails 
with a minimum width of 40mm for ±2400Pa load 
and a minimum width of 60mm for +5400 Pa 
/-2400Pa load.

·  Install and tighten the module clamps to the 

mounting rails using the torque stated by the 
mounting hardware manufacturer. System 
designer and installer are responsible for load 
calculations and for proper design of support 
structure. It is recommended to use a torque 
wrench for installation. Tightening torques should 
respectively be within 17~23 Nm (12.5~17.0 ft-lb) 
(23 Nm (17.0 ft-lb) is recommend) for M8x1.25-
Grade 8.8 coarse thread bolts, depending on bolt 
class. 

·   Use appropriate corrosion-proof fastening 

materials. All mounting hardware (bolts, spring 
washers, flat washers, nuts) should be made with 
stainless steel.  

·  Clamp material should be anodized aluminum 

alloy or steel of appropriate grade. One buffer 
rubber material (Recommended material is EPDM) 
must be added between the clamp and the glass.

·  Canadian Solar Inc. warranty may be void in cases 

where improper clamps or unsuitable installation 
methods are found. When installing clamps, take 

measures so as:

1. Not to bend the laminate excessively.
2. Not to cast shadow on the cells.
3. Not to damage or scratch the surface of the glass.
4. To ensure the clamps overlap the module by  

13 mm to 15 mm.

5. To ensure the thickness of the clamps is at  

least 3 mm.

·  Clamp positions are of crucial importance for the 

reliability of the installation, the clamp centerline 
must only be positioned within the authorized 
position ranges indicated in ANNEX B, depending 
on the configuration and load.

·   The module is only considered to comply with 

UL1703 when mounted as specified in the inst-
ructions in ANNEX B. Any module without a frame 
(laminate) shall not be considered to comply with 
the requirements of UL 1703 unless the module is 
mounted with hardware that has been tested and 
evaluated with the module under this standard or 
by a field Inspection certifying that the installed 
module complies with the requirements of UL 
1703.

·   Double glass modules can be mounted to a sup-

port structure by means of clamps. For recommen-
ded installation methods and load, please refer to 
ANNEX B and contact your local representative for 
further information. Failure to use a recognized 
installation method will void Canadian Solar Inc. 
warranty.

7.0 

MAINTENANCE

·  Regular maintenance is required to keep modules 

clear of snow, bird droppings, seeds, pollen, lea-
ves, branches, dirt spots, and dust.  

·  Modules with sufficient tilt (at least 15°), generally 

do not

 require cleaning (rain will have a self-

Nut

Rail

Glass

Spring washer
Flat washer

Rubber

Top Middle Clamp

Bolt Bottom Middle Clamp

Nut

Rail

Glass

Spring washer
Flat washer

Rubber

Top End Clamp

Bolt

Bottom End Clamp

Содержание Dymond CS6K-245P-FG

Страница 1: ...INSTALLATION MANUAL OF DYMOND MODULE For professional use only...

Страница 2: ...EN Rev IM FDM EN 1 6 Copyright March 2017 Canadian Solar Inc...

Страница 3: ...3 0 MECHANICAL ELECTRICAL SPECIFICATIONS 4 0 UNPACKING AND STORAGE 5 0 MODULE INSTALLATION 5 1 MODULE WIRING 5 2 MODULE GROUNDING 6 0 MOUNTING INSTRUCTIONS 7 0 MAINTENANCE AMENDED EDITIONS AND DATES...

Страница 4: ...cluding without limitation bodily harm injury or damage to property in connection with handling PV modules system installation or compliance or non compliance with the instructions set forth in this m...

Страница 5: ...rical Ratings Main electrical charac teristics under STC are also stated on each module label The maximum system voltage for double glass module type is 1000V UL and 1500V IEC Under certain conditions...

Страница 6: ...heavy loads may cause severe micro cracks at cell level which in turn may compromise module reliability Failure to comply with the above caution will void Canadian Solar Inc s warranty SYSTEM FIRE RA...

Страница 7: ...ing Only modules with similar electrical outputs should be connected in the same series to avoid or minimize mismatch effects in arrays To minimize risk in the event of an indirect light ning strike a...

Страница 8: ...ting system using UV resistant cable ties Protect exposed cables from damage by taking appropriate precautions e g placing them inside a plastic conduit Avoid exposure to direct sunlight A minimum ben...

Страница 9: ...overlap the module by 13 mm to 15 mm 5 To ensure the thickness of the clamps is at least 3 mm Clamp positions are of crucial importance for the reliability of the installation the clamp centerline mu...

Страница 10: ...8 8 9 92 CS6K 245M FG 245 30 3 8 09 37 4 8 61 15 1658 992 5 8 65 3 39 1 0 23 in without junction box and corner protector 23 CS6K 250M FG 250 30 4 8 22 37 5 8 74 CS6K 255M FG 255 30 5 8 35 37 7 8 87 C...

Страница 11: ...305 32 7 9 33 39 9 9 91 CS6K 310MS FG 310 32 9 9 43 40 1 9 99 CS6X 290P FG 290 35 9 8 08 44 4 8 64 15 1968 992 5 8mm 77 5 39 1 0 23 in without junction box and corner protector 27 5 CS6X 295P FG 295 3...

Страница 12: ...A Clamping on module long side four clamp points Mounting rails must run perpendicularly to the module long side Clamping Location Illustration Illustration A Clamping on module long side six clamp p...

Страница 13: ...mp length 100 mm four clamps A 380 20 mm see illustration A Downforce load 2400 Pa Uplift load 2400 Pa VDE CSA 2 C 2 Profi clamp wide 3 8 mm clamp length 200 mm four clamps A 380 20 mm see illustratio...

Страница 14: ...ngth 100 mm six clamps A 250 20 mm B 579 20 smm see illustration B Downforce load 5400 Pa Uplift load 2400 Pa VDE CSA 2 F 1 Akcome Metals Technology Suzhou Co Ltd AK EC DG End clamp AK MC DG Middle cl...

Страница 15: ...i clamp wide 3 8 mm clamp length 130 mm four clamps A 440 20 mm see illustration A Downforce load 2400 Pa Uplift load 2400 Pa VDE CSA 3 C 2 Profi clamp wide 3 8 mm clamp length 250 mm four clamps A 44...

Страница 16: ...1 End clamp PW CS 02 Middle clamp clamp length 100 mm six clamps A 300 20 mm B 684 20 mm see illustration B Downforce load 2400 Pa Uplift load 2400 Pa VDE CSA 3 E 4 PW CS 01 End clamp PW CS 02 Middle...

Отзывы: