This general manual provides important safety information relating to the installation, maintenance and handling of 
CS-series  solar  modules.  System  users  and  professional  installers  should  read  this  manual  carefully  and  strictly 
follow  the  instructions.  Failure  to  follow  these  instructions  may  result  in  death,  injury  or  property  damage.  The 
installation  of  solar  modules  requires  specialized  skills  and  should  only  be  performed  by  licensed  professionals.

1.0  GENERAL INFORMATION

1.1  DISCLAIMER OF INSTALLATION MANUAL

The information contained in this manual is subject to change by Canadian Solar Inc. without prior notice. Canadian 
Solar Inc. makes no warranty of any kind whatsoever, either explicitly or implicitly, with respect to the information 
contained herein. 

1.2  LIMITATION OF LIABILITY

Canadian Solar Inc. shall not be held responsible for damages of any kind, including without limitation bodily harm, 
injury and property damage, relating to module handling, system installation, or compliance or non-compliance with 
the instructions set forth in this manual.

2.0  SAFETY PRECAUTIONS

Warning:

 All instructions should be read and understood before attempting to install, wire, operate 

and/or maintain the module. Module interconnects pass direct current (DC) when exposed to 
sunlight or other light sources. Contact with electrically active parts of the module, such as 
terminals, can result in injury or death, whether the module is connected or disconnected.

Avertissement :

 Toutes les instructions devront être lues et comprises avant de procéder à 

l’installation, le câblage, l’exploitation et/ou l’entretien des panneaux. Les interconnexions des 
panneaux conduisent du courant continu (CC) lorsque le panneau est exposé à la lumière du soleil 
ou à d’autres sources lumineuses. Tout contact avec des éléments sous tension du panneau tels que 
ses bornes de sortie peut entraîner des blessures ou la mort, que le panneau soit connecté ou non.

·

All installations must be performed in compliance with all applicable regional and local codes such as, the latest 

    National Electrical Code (USA) or Canadian Electric Code (Canada) or other national or international electrical 
    standards.  

·

Wear suitable protection (non-slip gloves, clothes, etc.) to prevent direct contact with 30VDC or greater, and to 

    protect your hands from sharp edges during the installation.  

·

Use electrical insulated tools to reduce the risk of electric shock.

·

Remove all metallic jewelry prior to installation to reduce the chance of accidental exposure to live circuits.

·

Cover the front of the modules in the PV array with an opaque material to halt production of electricity when 

    installing or working with a module or wiring.

·

Do not install or handle the modules when they are wet or during periods of high wind.

·

Do not use or install broken modules.

·

If the front glass is broken, or the back sheet is torn, contact with any module surface or the frame can cause electric 

    shock.

·

Keep the junction box cover closed at all times.

·

Do not attempt to repair any part of the module. There're no serviceable parts within the PV module. 

·

Do not disassemble a module or remove any module part.

·

Do not artificially concentrate sunlight on a module.  

·

Do not connect or disconnect modules when current from the modules or an external source is present.

3.0  MECHANICAL / ELECTRICAL SPECIFICATIONS

2

The module electrical ratings are measured under Standard Test Conditions (STC) of 1 kW/m  irradiance with an 

AM1.5 spectrum, and cell temperature of 25

. The detailed electrical and mechanical characteristics of Canadian 

Solar Inc. crystalline silicon PV modules can be found in table A-2 of this manual (see Annex). Main electrical 
characteristics at STC also appear on each module label. The maximum system voltage for all modules series is either 
600V or 1000V. Please refer to the datasheet or the product nameplate for the maximum system voltage. 

General Safety

EN-Rev 2.3 Copyright     20

 Canadian Solar Inc.

12 Sep.

Under certain conditions, a module may produce more current or voltage than its Standard Test Conditions (STC) 
rated power. Accordingly, a module's open-circuit voltage and short-circuit current at STC should be multiplied by 
1.25 when determining component ratings and capacities. An additional 1.25 multiplier for a short-circuit current (for a 
total of 1.56), for sizing conductors and fuses may be applicable, as described in section 690-8 of U.S. NEC.

The word "module" or "PV module" used in this manual refers to one or more CS-Series Solar Modules.
Please retain this manual for future reference. It is recommended to regularly check online for the most updated 
version.

QUALITY  I  VALUE  I  INNOVATION  

Содержание CS Series

Страница 1: ... 12657 Alcosta Blvd Suite 140 San Ramon CA 94583 Tel 1 925 866 2700 Fax 1 925 866 2704 Email inquire us canadiansolar com Japan Round Cross Shinjuku 5 Chome 8F 5 17 Shinjuku Shinjuku ku Tokyo Japan 160 0022 Tel 03 5291 8591 Fax 03 5291 8596 Email inquire jp canadiansolar com Korea 201 SK HUB Officetel 708 26 Yeoksam Dong Kangnam gu Seoul Korea Tel 02 539 7541 Fax 02 539 7505 Email inquire kr canad...

Страница 2: ...thes etc to prevent direct contact with 30VDC or greater and to protect your hands from sharp edges during the installation Use electrical insulated tools to reduce the risk of electric shock Remove all metallic jewelry prior to installation to reduce the chance of accidental exposure to live circuits Cover the front of the modules in the PV array with an opaque material to halt production of elec...

Страница 3: ...tand all expected loads including wind and snow loads A minimum clearance of 6 5 mm 1 4 of an inch or more between modules is required to allow for thermal expansion of the frames Small openings for water draining on the underside of the module should not be blocked after mounting Optimum orientation and tilt Find out the optimum orientation and tilt of the PV modules for your region to achieve th...

Страница 4: ...er from the specifications then there is a wiring fault Correct connection of plug connectors Make sure that the connection is safe and tight The plug connector should not receive outer stress The connector should only be used to connect the circuit It should never be used to turn the circuit on and off Use of suitable materials Use special solar cable and suitable plugs only wiring should be plac...

Страница 5: ...dditional mounting points should be used System designer and installer are responsible for load calculations and for proper support structure design Modules should be bolted at the following hole locations depending on the configuration and load as verified by the test method in IEC 61215 Table 6 1 Authorized attachments for bolting method Bolting on short side frame except for 6X series Uplift lo...

Страница 6: ... PX CS6P 245P PM PX CS6P 250P PM PX Model Type Maximum power Pmax W Max Series Fuse Rating A Weight Kg Overall Dimension mm Operating Voltage Vmp V Open Circuit Voltage Voc V Short Circuit Current Isc A Operating current Imp A 20 30 1602X1061X40 10 00 20 30 1602X1061X40 10 00 10 00 19 00 1638 982 40 3 00 3 00 2 40 534 350 25 2 40 534 350 25 5 00 5 00 10 00 10 00 5 10 608 666 35 5 10 608 666 35 6 5...

Страница 7: ... copper conductor wire and allow connecting the system to equipment ground connector Model Type Maximum power Pmax W Max Series Fuse Rating A Weight Kg Overall Dimension mm Operating Voltage Vmp V Open Circuit Voltage Voc V Short Circuit Current Isc A Operating current Imp A CS6P 255P PM PX CS6P 260P PM PX CS6P 265PM CS6P 270PM CS6P 275PM CS6A 160M CS6A 165M CS6A 170M CS6A 175M CS6A 180M CS6A 185M...

Страница 8: ...n manual from UNIRAC or to UL SM_En A0 Technical B 4 GROUNDING METHOD D Rapid2 Grounding Middle Clamps Used in conjonction with any Schletter module mounting rail INTERTEK certified 2 Schletter Rapid Grounding Clamps are used to create a grounding path between the module frame and the mounting rail An integrated grounding pin ensures bonding to the module frame by penetrating the frame coating 2 T...

Страница 9: ...clamps on the long side the allowed range depends on the module type Authorized range for clamping as a function of model type Model type CS5A CS5P CS6A CS6P CS5T CS6X A1 range mm 220 380 220 390 220 340 240 410 340 550 B1 range mm 330 400 330 400 270 330 340 410 410 490 A2 range mm 170 200 220 270 200 250 200 250 200 250 A1 A1 A1 A1 B1 B1 B1 B1 Mounting rails may run perpendicularly or parallel t...

Страница 10: ... used for PV modules that are not compatible with flange clamp style Claws The Long Claw attaches at the module mounting holes using standard bolting method Refer to paragraph 6 1 for suitable torque and fastening requirements Step 4 Mount Modules to Supports Step 5 Electrical Grounding Refer to B 5 GROUNDING METHOD E Grounding for Grizzly Bear FR Gen II SYSTEM for grounding assembly and requireme...

Отзывы: