CAUTIONS

  CAUTION

1). Extremly important:  In heavy snow areas take extra care to

prevent against blocking vent termination with snow removal
equipment.

2). Flue gases exiting vent terminals are very hot and must not be

restricted to assure fireplace combustion is not affected.

3). Do not place, build any obstruction, plant any bushes or for any

reason attempt to conceal the vent termination.  To do so will
affect the operation of the fireplaceand may be hazardous.

4). Do not recess vent terminals into walls or siding.
5). Terminals with components which exceed 180 F+ ambient

while under continuous operation are required by National
Standards to be protected with an additional screen on patio's,
decks and any areas accessible to public.  For maximum safety
we recommend all terminals below 7' from grade level be
installed with a certified Econo Plus Heat Guard.

  INSTALLING THE GAS LINE

The gas line must be installed before finishing the Econo Plus
36DV-RV Fireplace.  Natural Gas requires an inlet pressure of
7" W.C. & a manifold pressure of 3.5" W.C. Propane Gas
requires an inlet pressure of 11" W.C. & a manifold pressure of
10.5" W.C.  It is also required that provisions be made for a
1/8" N.P.T. plugged tapping and be accessable for test gauge
connection immediately upstream of the gas supply controls to
the appliance.  The fireplace gas connection and the main
operating gas valve is located behind the removable brass trim
at the bottom of the unit and need only be attached to the gas line
with an approved fitting, as required by the CAN/CGA B-149.1
and .2
 Gas Installation Code.

  

*After gas line is connected, it is a CAN/CGA B149.1 & .2. code

requirement  (Section 8.25.3 (e)) that "each appliance connection,
valve, valve train, shall be checked while under normal operating
pressure with either a liquid solution, or leak detection device, to
locate any source of leak." Tighten any areas where bubbling
appears or leak is detected  until bubbling stops completely or leak
is no longer detected.  Do NOT  use  a flame of  any  kind to test  for
leaks

  VENT TERMINATION LOCATION

Refer to the section on selecting a fireplace location to determine
where your Econo Plus 36DV-RV will be installed.

Next, determine the vent terminal location. (see appendix A) for
allowed areas.  The outlet must be framed with an 12" x 12" inside
dimension (see Figure 4).

VENT  TERMINATIONS SHALL NOT BE RECESSED IN
WALLS OR SIDING.

FOR DETAILED SKETCH OF ALLOWED

TERMINATION LOCATIONS SEE APPENDIX A

FOR VINYL SIDING APPLICATIONS ALL ETK
TERMINATIONS MUST BE INSTALLED WITH A
HEAT SHIELD (MTKG) TO PROTECT THE SIDING
FROM ANY HEAT DAMAGE.  ETKO TERMINATIONS
DO NOT REQUIRE A HEAT SHIELD.

FIGURE 4.    VENT  TERMINATION FRAMING.

*

IMPORTANT:

When using ETK or ETKO with
MOSR:
 Framed opening must be
12" X 12"

When using ETK or ETKO:
Framed opening must be 11" X 11"

*

12

12

*

ETK-5 or ETK-9

ETKO-5 or ETKO-9

  INSTALLING DIRECT VENT

Note:  DO NOT STRETCH    flexible connectors to gain
extra length.  These connectors are flexible only to allow
for directional  changes, which must not exceed 90
degrees.

All vent pipes must maintain a minimum of 1"
clearance to combustible materials.

Note: It is imperative for satisfactory operation of the
Econo Plus 36DV-RV fireplace that no venting component
be modified in any way.  All components have been
manufactured to eliminate the need for modification when
properly selected and installed.

Содержание Econo-Plus 36DV-RV

Страница 1: ...BEFORE INSTALLING MODEL ECONO PLUS36DV RV ECONO PLUS36DV RV FOR YOUR SAFETY FOR YOUR SAFETY IF YOU SMELL GAS 1 OPENWINDOWS DONOTSTOREORUSEANYFLAMMABLE 2 DON TTOUCHELECTRICALSWITCHES VAPOURSORLIQUIDSN...

Страница 2: ...y builtgasfireplaces Installation repairs should be done by a qualified contractor andinstallationmustconformwiththecurrentCAN CGA B 149 1 and 2 Gas Installation Code and local regulations CAUTIONS Du...

Страница 3: ...tion Code After gas line is connected it is a CAN CGA B149 1 2 code requirement Section 8 25 3 e that each appliance connection valve valve train shall be checked while under normal operating pressure...

Страница 4: ...UTIONS AND REQUIREMENTS 2 Extended vent kit For extended vent use a stucco frame 20 extended vent and a termination Note 20 kit may be cut to desired length but must never exceed 20 see figure 6 ETK 5...

Страница 5: ...linterferewith the access to retainers for removal of glass panel and combustion door NOTE National Canadian Gas Association mantel test requirements are for fire hazard prevention to combustible mate...

Страница 6: ...o install simply place log A s rectangular shaped extension into the log mounting slot located on rear wall of the burner assembly Place log B onto front log slots Place log C and log D onto pins on t...

Страница 7: ...be cleaned periodically Film can easily be removed by removing inner and outer doors handling carefully and cleaning with normal liquid household products WARNING Do not attempt to clean glass when h...

Страница 8: ...denial of certification by recognized national safety agencies and could be in violation of local building codes This warranty does not cover any damages occurring from the use of any components not m...

Отзывы: