7 Commissioning
Configuration parameters 869 MHz
Value
Description
Comment
HF Rate
Modulation
20k (LR DSSS FEC) @ 100 kHz
method
Channel 1 or 3 only
Highest range, slow
38.4k (GFSK) @ 100 kHz Bandwidth-
Channel 1 or 3 only
50k (GFSK) @ 200 kHz Bandwidth -
Channel 3 only
100k (GFSK) @ 200 kHz Bandwidth -
Channel 3 only
Low range, fast
Channel
Radio channel
00: 869.40 MHz Not allowed
(Frequency)
01: 869.45 MHz
02: 869.50 MHz
03: 869.55 MHz
04: 869.60 MHz
HF Power Level
Transmitting power
12-25 dBm
test
ATTENTION!
Selectable settings are CE compliant according to EN 300 220 standard.
Other combinations are not permitted!
NOTE: The higher the RF rate, the faster the transmission but the range is
shorter
All devices in a radio system must be set to the same radio channel.
DATAEAGLE radio systems in parallel operation are to be operated with
different radio channels! However, it should be noted that at high RF rate only 1
system is possible due to the available bandwidth!
It makes sense to reduce the transmitting power in order not to influence
neighboring radio systems in the same frequency band!