15
CAN Srl
–
CU 3002
–
ENGLISH
–
Rev 1/2018
It is possible to use flexible connection tubes, however they must guarantee
compliance with the following requirements:
▪
Tubes always inspectionable
▪
Tubes protected from contact with hot parts (e.g. burner bowls)
▪
Avoid all mechanical stress on flexible tubing during installation and
during use (protection against traction, torsion, crushing, etc...)
▪
Tubes protected against mobile parts of fitting (drawings, doors, etc...)
▪
Permitted lengths: from 40 cm to 200 cm
▪
Maintenance and periodic replacement of the flexible tube as outlined
on the sheath and however not beyond the natural expiry or before
expiry if visible torn.
Proceed to connection:
The main ramp of the gas supply has an 8 mm outer diameter tube with
a free, smooth end, to allow maximum connection flexibility and to
connect a wide range of compression fittings for connection to the gas
distribution mains.
ATTENTION - During the installation and connection operations, the gas
conductor tube of the appliance must not be subject to torsion, traction
or other mechanical stresses which can compromise its seal and
resistance. The portion of the system subject to connection to the
appliance must not be overfull with gas. The outflow of gaseous fuel
should be blocked upstream of the connection zone using an adequate
sectioning valve on the system.
With installation complete, check correct seal of all the joints using a solution of
water and soap. The operation should be carried out by a professional.
FORBIDDEN - NEVER USE OPEN FLAMES BEFORE PASSING THE INSPECTION
TEST!
IF THE OUTCOME OF THE TEST IS SATISFACTORY, you can proceed to
switch on all the burners (consult page 24) to check the flame is stable
and regular.