You can set the transfer rate, the Can Bus speed, and the addresses for sending and receiving the Can 
Bus messages. As always, the Can Bus speed is identical in ECU and MCE18. In the following table you 
will find the exact addresses of the individual inputs and outputs in the standard protocol. 

Byte 

TX 
Base 
ID 

AIN0  

0-1023 

AIN1 

0-1023 

AIN2 

0-1023 

AIN3 

0-1023 

TX 
Base 
ID +1 

AIN4 

0-1023 

AIN5 

0-1023 

AIN6 

0-1023 

AIN7 

0-1023 

TX 
Base 
ID +2 

AIN8 

0-1023 

Bit 
masked 
DIN0-7 

Bit 
masked 
AUX1-3 

 

 

internal
Temp 

version 

TX 
Base 
ID +3 

FreqIn1 

0-60000 

FreqIn2 

0-60000 

FreqIn3 

0-60000  FreqIn4 

0-60000 

 

Furthermore, you can also configure the 20-50 kOhm software pullups for the digital and analog 
inputs in Settings. You can switch between OFF and ACTIVE. 

If the internal pull-up is activated, the digital input should be switched to ground. If it is not activated, 
the input can be switched to 5 or 12V. The "HIGH" state corresponds to a 1 on the Can bus. 

 

 

 

Furthermore, under the item AIN smoothing you will find the possibility to calm your analog inputs.  

Содержание MCE18

Страница 1: ...MCE CFE18 Manual...

Страница 2: ...ter 14 5 3 MaxxECU and others 14 6 FAQ 15 6 1 Does the MCE18 come pre configured 15 6 2 My inputs influence each other 15 6 3 Unable to connect to DSS 15 6 4 How to Choose the Right Offset Multiplier...

Страница 3: ...g this guide also covers the connection and operation of our Device Setup Software DSS In the box you will not only find the MCE18 but also the following items are included The Quickstart Guide one AM...

Страница 4: ...Rev 1 0 4 The following illustration shows the dimensions of the MCE18...

Страница 5: ...pinout is to be read as if the tab were up 2 0 8 0 8a ATTENTION Pinout identical to V3 only A6 and A7 are swapped Firmware CFE18v0 8XX 3 0 8b present Firmware MCE18v0 9XX The MCE18 has analog inputs...

Страница 6: ...he download is free of charge at https www canchecked de downloads category dss display setup software The DSS is available for Win32 Win64 and MacOS The following manual only partially covers V1 devi...

Страница 7: ...B cable to the Superseal connector yourself Illustration 1 USB Cable Colors Red USB 5V Pin 5 Green USB Data Pin 6 White USB Data Pin 7 Black USB GND Pin 8 Once the MCE18 is properly wired and plugged...

Страница 8: ...checked logo to get to the selection field of the device to be connected Illustration 2 DSS Startup Here you click on the selection field for addon below and now you will get to the tab overview If yo...

Страница 9: ...0 1023 AIN7 0 1023 TX Base ID 2 AIN8 0 1023 Bit masked DIN0 7 Bit masked AUX1 3 internal Temp version TX Base ID 3 FreqIn1 0 60000 FreqIn2 0 60000 FreqIn3 0 60000 FreqIn4 0 60000 Furthermore you can a...

Страница 10: ...ximum input frequency is 65kHz You can adjust the damping in different levels 4 2 LiveData Under the LiveData tab you will find the current measured values and statuses of your inputs and outputs By c...

Страница 11: ...with Haltech In the table below you will find an assignment of the MCE18 pins to the pins of the IO boxes MCE18 Pin IO A IO B IO A B A0 AV1 AV1 IO A AV1 A1 AV2 AV2 IO A AV2 A2 AV3 AV3 IO A AV3 A3 AV4...

Страница 12: ...ues in the Haltech NSP software Here are the steps to be taken In the drop down menu activate the port to which the IO box will be connected Then select the expander box you want to emulate use the sa...

Страница 13: ...Rev 1 0 13 Then all you have to do is check whether your Haltech ECU correctly recognizes the MCE18 as an expander Status connected Firmware 1 23 0...

Страница 14: ...e EMU software under CAN Serial To do this please tick the box and select CSB V3 0x640 as the CSB type Furthermore the checkmarks for the individual AINs must be set As usual all changes are written t...

Страница 15: ...essary The corresponding steps are described in chapter 4 described 6 4 How to Choose the Right Offset Multiplier Divider and Resolution The analog inputs provide 10bit resolution and thus values from...

Страница 16: ...commended to minimize the Can Bus load 6 10 How to connect a Flexfuelsensor Connect the flex fuel sensor with the signal to DIN 6 Ground and 5V can be taken directly from the MCE18 An external resisto...

Страница 17: ...Rev 1 0 17 7 Document Changelog Rev 1 0 initial Version for Firmware 0 9...

Отзывы: