45
Slave Boiler
Description
Electrical Connection(s)
Programming Instructions
Slave boiler lead lag
setup
System temperature
sensor must be
connected to boiler #1.
Outdoor temperature
sensor must be
connected to boiler #2.
1)
Place toggle switch to
LOCAL
2)
Press
and
3)
Select
System Identification & Access
4)
Verify
Modbus address
. To be in sequential order
5)
Select
Lead Lag Slave Configuration
6)
Select
Slave Enabled = Enable slave for built-in Lead Lag master
The following steps are performed at the factory and verifying on site
will be sufficient:
7)
Select
Pump Configuration
8)
Press
[Advanced Options >>]
9)
Press the to arrive at
Central Heat Pump
or
DHW Pump
10) On Options:
Local burner demand
11) On Options: Local Lead Lag
Service Active
12) Force On:
Outlet high limit
Master Boiler, System Sensor (Connected to Master Boiler #1)
Description
Electrical Connection(s)
Programming Instructions
Master boiler system
sensor configuration
System temperature
sensor must be
connected to boiler #1.
Outdoor temperature
sensor must be
connected to boiler #2.
1)
Press
and
2)
Press
[Sensor Configuration]
3)
Select
S5 (J8-11) Sensor
4)
Connector Type:
10K NTC Single Non-Safety
5)
The control will proceed into a Lockout 2 condition
6)
Press
[Verify]
>
[Begin]
>
[Yes]
7)
Press the reset button on the ignition control within the alotted time
Outdoor Sensor connected to Slave boiler 2 (AVH ONLY)
Description
Electrical Connection(s)
Programming Instructions
Slave boiler outdoor
sensor configuration
Outdoor temperature
sensor must be
connected to boiler #2.
When done correctly,
the outdoor
temperature will be
shown on the Master
boiler
Slave Boiler
1)
Press
and
2)
Press
Sensor Configuration
3)
Select
S5 (J8-11) Sensor
4)
Select
Connector type = 10K single non-safety
Содержание ADVANTUS AVH 500
Страница 2: ......
Страница 3: ......
Страница 38: ...31 Figure 23 Recommended Piping with Reverse Return and Variable Primary Flow...
Страница 70: ...63 Figure 44 Typical Gas Train Models AV1000 3000 Figure 45 Typical Gas Train Models AV3500 4000...
Страница 88: ...81 PART 12 EXPLODED VIEW Figure A...
Страница 89: ...82 Figure B FAN BURNER ASSEMBLY AV500 600 some items may not be as shown...
Страница 90: ...83 Figure C FAN BURNER ASSEMBLY AV800 4000 some items may not be as shown...
Страница 91: ...84 Figure D Figure E...
Страница 92: ...85 Figure F Figure G...
Страница 93: ...86 Figure H CONTROL BOARD ASSEMBLY...
Страница 100: ...93 PART 13 ELECTRICAL DIAGRAMS...
Страница 101: ...94...
Страница 102: ...95...