background image

HSEUREG04801(R2) MANUAL

Mechanics 

ST-HD Baseplate Cooling & Temperature Management

 

The temperature management of the HSEUREG series provides a direct dissipation of the main energy losses. 
The internal coolers of the output diodes and the power FETs connect to the back-plate cooler. It is possible to 
dissipate about 40 – 50% of the energy losses out of a system while using the Baseplate cooling bundle 
2201002001 to hard mount the unit to a plane and heat conductive surface. 

[email protected]

www.powersolve.co.uk

020321

Содержание Powersolve HSEUREG04801 Series

Страница 1: ...or long life under full stress Strong input filters High reliability shock vibration proof Over Voltage and continuous short circuit protection EMI EMS EN61000 6 2 3 EN55032 class B EN61010 1 EN61010...

Страница 2: ...t quality and most reliable devices in the world market Design Conception The HSEUREG power supply series realizes high programmable power in a space saving housing Latest generation electrical device...

Страница 3: ...cy for 0 Umax programming Startup Delay Typ 250ms Softstart Typ 100ms Startup from Shutdown Typ 250ms Response Load Change 1ms 10 100 100 10 Base Load None Efficiency 230Vac 90 typical Short Circuit P...

Страница 4: ...mote ON OFF Open Collector or Switch Voltage drop 1V with typical 2 3mA 6 Remote Input Programming Interface Ureg The standard programming of the HSEUREG Series is an analogue interface The output vol...

Страница 5: ...he sense block has only connections We recommend twisted sense lines Local Sensing Remote Sensing Compensation of Load Line Drop Voltage Sense battery charger operation mode Remote Sensing as a batter...

Страница 6: ...point or busbar To avoid measurement errors select the line length from the neutral point or from the busbar to the load as short as possible and use the maximum possible conductor cross section The H...

Страница 7: ...f the main energy losses The internal coolers of the output diodes and the power FETs connect to the back plate cooler It is possible to dissipate about 40 50 of the energy losses out of a system whil...

Страница 8: ...DIN Rail bracket according to EN60715 It is easy to mount dismount while snaping it onto the 35mm DIN Rail no tools necessary It is not allowed to install the HSEUREG in other mounting direction then...

Страница 9: ...tripping Length 0 25mm H0 25 5 5mm H0 25 10 HBL 8mm 0 5mm H0 5 6 6mm H0 5 12 OR 8mm 1 0mm H1 0 6 6mm H1 0 12 GE 8mm 2 5mm H2 5 12 12mm H2 5 19D BL 14mm 4 0mm H4 0 12 12mm H4 0 20 GDR 14mm 6 0mm H6 0 2...

Страница 10: ...persons or things 4 Note The device must not be operated without an upstream circuit breaker CB We recommend the use of C Type 16A for 230Vac and for 115Vac It is prohibited to use the unit without PE...

Отзывы: