HSEUREG04801(R2) MANUAL

Technical Table 

AC Input Range 

90-132Vac, 184-264Vac (115/230Vac input selector, factory setting is 230Vac)

AC Input Frequency 

47-63Hz

DC Input Range 

250Vdc-375Vdc (input selector set to 230Vac) 

AC Input Rated 

115Vac<9.0A  230Vac<4.9A 

DC Input Rated 

250Vdc<2.4A  375Vdc<1.6A (input selector set to 230Vac rated) 

DC Voltage Programmable 

0 - 15V 

0 - 30V 

0 - 50V 

0 - 90V 

0 - 130V 

0 - 180V 

DC Current Rated +60°C 

26.0A 

16.0A 

10.0A 

5.3A 

3.7A 

2.7A 

DC Current Rated +70°C 

19.5A 

12.0A 

7.5A 

4.0A 

2.8A 

2.0A 

Power Boost 60s +60°C 

28.6A 

17.6A 

11.0A 

5.8A 

4.1A 

3.0A 

Over Voltage Protection 

18Vdc 

35Vdc 

59Vdc 

105Vdc 

150Vdc 

210Vdc 

Over Current Protection 

30.0A 

18.4A 

11,5A 

6,1A 

4,3A 

3.1A 

Ripple Noise 230Vac 20MHz 

40mVpp 

50mVpp 

100mVpp 

150mVpp 

200mVpp 

300mVpp 

Load regulation 0-100% 

< ±0.1% 

< ±0.1% 

< ±0.1% 

< ±0.1% 

< ±0.1% 

< ±0.1% 

Sense function 

Compensation 2V per lead load, protective electrical separation 

60Vdc 

Remote Shutdown 

protective electrical separation 

60Vdc 

Analogue Interface 

see table, protective electrical separation 

60Vdc, working impedance = 500

Ω

 

Accuracy 

< ± 1.5% Interface 

Latency Interface 

15ms including signal latency for 0-Umax programming 

Startup Delay 

Typ. 250ms 

Softstart 

Typ. 100ms 

Startup from Shutdown 

Typ. 250ms 

Response Load Change 

<1ms 10-100%, 100-10% 

Base Load 

None 

Efficiency 230Vac 

90% typical 

Short Circuit Protection 

Continuous 

Idling-proof 

Yes 

Temperature Control 

Yes, thermal shutdown with auto recovery (+70°C, metering distance 50mm) 

Hold Up Time 

> 50ms 230Vac

Inrush Current 

< 81A (230Vac) @25°C 

MCB (Miniature Circuit Breaker)  16A curve C @ 230Vac, 16A curve C @ 115Vac 
Cooling 

Natural convection 

Ambient Operating Temp. 

- 25°C…+70°C, derating 2,5%/°C >60°C

Ambient Storage Temp. 

- 40°C…+85°C

Environment 

Humidity 95% non-condensing @ 25°C, climate class. 3k3, pollution degree 2 

ROHS 

2011/65/EU, (EU)2015/863 

REACH 

EG No. 1907/2006 

EMI 

EN55032 class B, EN61000-6-3 

EMS 

EN61000-6-2 

Safety 

EN61010-1, EN61010-2-201, EN62368-1, EN60950-1, EN60204-1 

Protection Class I 

PE connection required 

Creepage Distance 

> 8mm

Input / Output 

Galvanic isolated 

MTBF (IEC61709) 

400000h (Meantime Between Failures: statistic time between failures after repairs) 

MTTF (IEC61709) 

142053h (Meantime To Failure: statistic time to ever fails) 

Dimensions (HxWxD) 

130x200x115mm 

Weight 

2,8kg / 6,2lbs 

AC Terminals 

Input Screw Terminal 3x AWG22 – AWG6 / 0,5 – 16mm² (L,N,PE) 

DC Terminals 

Output Screw Terminal 4x AWG22 – AWG6 / 0,5 – 16mm² (+ + / - - ) 

[email protected]

www.powersolve.co.uk

020321

Содержание Powersolve HSEUREG04801 Series

Страница 1: ...or long life under full stress Strong input filters High reliability shock vibration proof Over Voltage and continuous short circuit protection EMI EMS EN61000 6 2 3 EN55032 class B EN61010 1 EN61010...

Страница 2: ...t quality and most reliable devices in the world market Design Conception The HSEUREG power supply series realizes high programmable power in a space saving housing Latest generation electrical device...

Страница 3: ...cy for 0 Umax programming Startup Delay Typ 250ms Softstart Typ 100ms Startup from Shutdown Typ 250ms Response Load Change 1ms 10 100 100 10 Base Load None Efficiency 230Vac 90 typical Short Circuit P...

Страница 4: ...mote ON OFF Open Collector or Switch Voltage drop 1V with typical 2 3mA 6 Remote Input Programming Interface Ureg The standard programming of the HSEUREG Series is an analogue interface The output vol...

Страница 5: ...he sense block has only connections We recommend twisted sense lines Local Sensing Remote Sensing Compensation of Load Line Drop Voltage Sense battery charger operation mode Remote Sensing as a batter...

Страница 6: ...point or busbar To avoid measurement errors select the line length from the neutral point or from the busbar to the load as short as possible and use the maximum possible conductor cross section The H...

Страница 7: ...f the main energy losses The internal coolers of the output diodes and the power FETs connect to the back plate cooler It is possible to dissipate about 40 50 of the energy losses out of a system whil...

Страница 8: ...DIN Rail bracket according to EN60715 It is easy to mount dismount while snaping it onto the 35mm DIN Rail no tools necessary It is not allowed to install the HSEUREG in other mounting direction then...

Страница 9: ...tripping Length 0 25mm H0 25 5 5mm H0 25 10 HBL 8mm 0 5mm H0 5 6 6mm H0 5 12 OR 8mm 1 0mm H1 0 6 6mm H1 0 12 GE 8mm 2 5mm H2 5 12 12mm H2 5 19D BL 14mm 4 0mm H4 0 12 12mm H4 0 20 GDR 14mm 6 0mm H6 0 2...

Страница 10: ...persons or things 4 Note The device must not be operated without an upstream circuit breaker CB We recommend the use of C Type 16A for 230Vac and for 115Vac It is prohibited to use the unit without PE...

Отзывы: