background image

 

Camtec Power Supplies GmbH  -  Gewerbestrasse 30  -  76327 Pfinztal  -  Germany        

p. 2/5 (07.2014-04-1)

 

Phone +49(721)46596-0  -   Fax +49(721)46596-77  -   

www.camtec-gmbh.com

 - 

[email protected]

 

(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death

 

 

 

Technical Data Table 

AC Input Range 

85…132Vac / 184…265Vac, 47…63Hz, 250…375Vdc (set input selector to 230VAC) 

AC Nominal Input 

115Vac <4.8A / 230Vac <2.2A 

Model Name 

HSE03201.05T 

HSE03201.12T 

HSE03201.15T 

HSE03201.24T 

Nominal Voltage 

5V 

12V 

15V 

24V  

Nominal Current 

18.0A 

18.0A 

17.0A 

13.5A 

Boost Current 60s 

21.6A 

21.6A 

20.4A 

16.2A 

Voltage Set Range 

5,0…9,0V 

11,4…14,4V 

14,2…18,0V 

22,5…28,8V 

Ripple 230Vac/20MHz 

25mVpp 

30mVpp 

30mVpp 

20mVpp 

Stability Load Switch 0-100% 

± 0,3% 

± 0,3% 

± 0,3% 

± 0,3% 

Model Name 

HSE03201.36T 

HSE03201.48T 

HSE03201.60T 

 

Nominal Voltage 

36V 

48V 

48V 

 

Nominal Current 

8.9A 

6.7A 

5.4A 

 

Boost Current 60s 

10.7A 

8.1A 

6.6A 

 

Voltage Set Range 

34,2…43,2V 

34,2…39,6V 

45,6…52,8V 

 

Ripple 230Vac/20MHz 

30mVpp 

50mVpp 

50mVpp 

 

Stability Load Switch 0-100% 

± 0,5% 

± 0,5% 

± 0,5% 

 

Power 

320W continuous 

Operation Failure Relay 

Yes, break contact isolated up to 60Vdc 

Factory Adjust. Tolerance V

out

 

± 1% 

Load regulation 

< ± 0.5% 10-100%, 100-10% 

Response to Load Change 

<1ms 10-100%, 100-10% 

Short Circuit Protection 

Continuous 

Open Circuit Proof 

Continuous 

Efficiency 

91% typical at 90% load 

Load Protection 

1,2x I

rated 

with auto recovery 

Voltage Protection 

140% of U

out 

with auto recovery 

Hold Up Time 

> 30ms 230Vac 

Inrush Current 

< 10.6Aeff / 15Apeak active inrush current limiter inside 

MCB (Circuit Breaker) 

4A type-B 230Vac and 6A type-B 115Vac with 6kA each recommended 

Softstart  

20ms typical 

Cooling 

Natural convection 

Derating 

+60°C…+70°C 2.5%/°C 

Ambient Temperature 

- 20°C…+70°C 

Storage Temperature 

- 40°C…+85°C 

EMI 

EN55022 class B / EN61000-3-2 

EMS 

EN61000-6-2,3 

Safety 

EN60950-1, EN60204-1 

Safety class 1(A) 

VDE0805, VDE0100 

Isolation Paths 

> 8mm creepage distance & clearance paths 

Input to Output Isolation 

3000Vac 

Input to Case Isolation 

2000Vac 

Output to Case 

500Vdc, models 

60Vdc 2400Vdc 

MTBF EN61209 

500.000h 

MTTF EN61209.SN29500 

154.300h @ 40°C 24/7 85% load 

Environment 

Humidity 90% non-condensing @ 25°C, climate class. 3k3, pollution rate II  

Altitude Operations 

3000m NN / 9842 ft. above sea level 

Dimensions (HxWxD) 

124x120x99.5mm 

ROHS 

2011/65/EG confirmed 

REACH 

EG No. 1907/2006 confirmed 

Weight 

1200g 

Connectors Option (AC & DC) 

Spring-type terminal with cable protection 0,5...6mm² 21…10AWG according with IEC/EN60664-
1, IEC/EN61984. Use copper conductors only. Tightening torque per terminal block is 0.5 - 0.6 
Nm / 4.5 - 5.3 lbf-in, strip 4.5mm 

 

 

 

 

 

 

 

 

Содержание HSE03201 Series

Страница 1: ...housing Up to 91 efficiency 20 C 60 C full output power C V curve down to 0V no fold back Free air convection Galvanic insulated Continuous short circuit protected Overload low voltage protected Open Circuit Proof Soft start auto recovery Hold up time 30ms Switching frequency typ 100KHz EMI EMS EN61000 6 2 3 EN55022 class B PFC EN61000 3 2 class A IEC EN 60950 1 Series parallel operation DIN Rail ...

Страница 2: ... Vout 1 Load regulation 0 5 10 100 100 10 Response to Load Change 1ms 10 100 100 10 Short Circuit Protection Continuous Open Circuit Proof Continuous Efficiency 91 typical at 90 load Load Protection 1 2x Irated with auto recovery Voltage Protection 140 of Uout with auto recovery Hold Up Time 30ms 230Vac Inrush Current 10 6Aeff 15Apeak active inrush current limiter inside MCB Circuit Breaker 4A typ...

Страница 3: ...Voltage Protection Derating OT Over Temperature The maximum ambient temperature is 70 C There is temperature protection inside the power supply When the temperature exceeds a certain level the HSR03201 will be shut down The unit provides an automatic restart when the temperature returns to applicable conditions OVP Over Voltage Protection Exceeding the OVP results into ticker mode Resuming the fai...

Страница 4: ...which apply the voltage with a slow ramp b Connect L1 and N together as well as all output poles c Use only AC test voltages with 50 60Hz The output voltage is floating and has no ohmic reference to ground d If testing output voltages are 60Vdc remain to security directives Use only isolated screw drivers to adjust output voltages Mechanics Installation Instruction of the HSR03201 Stable metal alu...

Страница 5: ...evention 2 Installation and service only by trained persons The AC power must be switched off The work is to be labeled accidental reconnection of the system must be prevented 3 Opening the device its modification loosening bolts or operation outside the specified herein specification or in an unsuitable environment has the immediate loss of warranty to follow We disclaim any responsibility for an...

Отзывы: