CPS-i3000(R2) MANUAL 

Camtec Power Supplies GmbH  -  Gewerbestrasse 30  -  DE-76327  Pfinztal / Germany   

P.4/22 (04/2016.01.5) 

Tel. +49 (721) 46596 - 0  Fax +49 (721) 46596 - 77    

www.camtec-gmbh.com

   -   

[email protected]

 

(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death) 

 

Technical Data Table 

AC Input Range 

184-264Vac 

AC Input Frequency 

47-63Hz 

DC Input Range 

250-375Vdc 

AC Input Rated 

230Vac <15,0A 

DC Input Rated 

250Vdc <14,0A  375Vdc <9.3A 

DC Voltage Programmable 

0 - 18Vdc 

0 - 30Vdc 

0 - 60Vdc 

0 - 90Vdc 

0 - 150Vdc 

0 - 300V 

DC Current Programmable 

0 - 185A 

0 - 125A 

0 - 62,5A 

0 - 41,5A 

0 - 25A 

0 - 12,5A 

Over Voltage Protection 

21Vdc 

35Vdc 

70Vdc 

105Vdc 

175Vdc 

350Vdc 

Over Current Protection 

204A 

138A 

69A 

46A 

27,5A 

13,8A 

Ripple Noise 230Vac 20MHz  35mVpp 

35mVpp 

75mVpp 

100mVpp 

200mVpp 

400mVpp 

Auxiliary Voltage 

12Vdc/0,5A accuracy ±0,5V R&N 30mVpp, not influenced from SB, SD, INH operations 

Power Rated 

3000W, 2700W 0-18Vdc, 184-264Vac 

Cooling 

Continuously controlled and monitored fans from EBM Papst (Germany) 

Efficiency 

typ. 92-94% 230Vac at full load  

Power Factor Control (PFC) 

0,99 / 230Vac under full load 

Short Circuit Resistance 

yes 

Open Circuit Protected 

yes 

Base Load (OCP) 

Non required (open circuit protected) 

Load Regulation 

< ± 0,05% 0-100% 

Load Regulation Time 

<1ms on load switch 10-100% 

Accuracy 

Ureg: 

 ± 0,5%, Ireg: 

 ± 1%, Umon: 

 ± 0,5%, Imon: 

 ± 1%, Uref: 

 ±1% 

Temperature Control 

yes, thermal shutdown & autorecovery (+70°C, outside measuring point distance 10mm) 

Hold Up Time 

>20ms 230Vac

 

mains buffering at full load 

Inrush Current 

<14,6Aeff <20,7Apeak 230Vac active electronic inrush protection (no simple NTC) 

Startup Delay 

typ. 1s 

Softstart 

typ. 100ms 

Ambient Temperature 

- 20°C…+60°C operating, derating 2,5%/°C >50°C 

Storage Temperature 

- 40°C…+85°C 

Ambient Conditions 

Humidity 95% non-condensing @ 25°C, climate class 3K3, pollution degree 2 

ROHS 

2011/65/EU, (EU) 2015/863 conform 

REACH 

EG No. 1907/2006 conform 

EMI for the models 

EN55032, conducted .018/.030/.060 class B / .090/.150/.300 class A, all models radiated class A 

EMS/EMI 

EN61000-6-2,3,4 

Safety 

EN61010-1, EN61010-2-201, EN62368-1, EN60950-1, EN60204-1 

Protection Class I 

PE connection required 

Leakage Current 

Typical 1.9mA, <2.8mA, 230Vac 50Hz 

Isolation Input to Output 

3000Vac 

Isolation Input to Case 

2500Vac 

Isolation Output to Case 

500Vdc , 

60Vdc= 2800Vdc 

MTBF (IEC61709) 

419000h (Meantime Between Failures: statistic time between failures after repairs) 

MTTF (IEC61709) 

146105h (Meantime To Failure: statistic time to ever fails) 

Dimensions (HxWxD) 

84x126,4x444mm | 3,3x5x17,5 Inch (without frontplate, note cable outlet in planning) 

Weight 

4,4kg / 9,7lbs 

Input Power Connections 

Neutrik NAC3FCA (locked by bajonett) included 

Output Power Connections 

Brass-Powerbars with metric M8 thread, a touch protection is included 

 

Programming Time Vout [ms] 

Model

 

0-18Vdc 

0-30Vdc 

0-60Vdc 

0-90Vdc 

0-150Vdc 

0-300Vdc 

Rise Time 0-100%, 10/100% Load, [ms] typ. 

15/15 

15/15

 

15/15

 

15/15

 

15/15

 

15/15 

Slew Rate 90-10%, 10/100% Load, [ms] typ. 

19/1,9 

46/4,6 

33/3,3 

23/2,3 

31/3,1 

26/2,6 

Slew Rate PS-Option 100-0%, 0% Load, [ms] typ. 

200 

200 

200 

200 

200 

200 

Output Capacity, [mF] typ. 

19,4 

19,4 

3,5 

1,07 

0,52 

0,11 

Latency [ms] 

 
 
 
 
 
 
 
 
 
 
 

Содержание CPS-i3000

Страница 1: ...ogramming Real time I V monitoring Reference voltage f autonomous programming CSB Current Share Bus Inhibit for safe interlocking Remote Shutdown Remote Shutdown Power Good Relay AC ok and DC ok Preci...

Страница 2: ...gn specifications call for the highest standards of safety and interference suppression The device was developed in accordance with the requirements of EN61010 1 EN61010 2 201 EN62368 1 and the EMC st...

Страница 3: ...no ticker operation Master Slave Mode Ureg OUT Ireg OUT The master slave mode can be defined in the parallel operation One device can be set as the master the other involved network units act as a sla...

Страница 4: ...easuring point distance 10mm Hold Up Time 20ms 230Vac mains buffering at full load Inrush Current 14 6Aeff 20 7Apeak 230Vac active electronic inrush protection no simple NTC Startup Delay typ 1s Softs...

Страница 5: ...nhibit Active Open Collector 9 OT Output Signal Over Temperature Open Collector 10 TA Output Signal Temperature Alarm Open Collector Early warning 11 OCP Output Signal Over Current Protection Open Col...

Страница 6: ...el 49 721 46596 0 Fax 49 721 46596 77 www camtec gmbh com info camtec gmbh com Subject to alterations This product is not designed to be used in applications such as life support systems wherein a fai...

Страница 7: ...C 250Vac 20A Neutrik PowerCon 3x2 5 mm Neutrik NAC3FCA Copy of the original instruction http www neutrik com de powercon powercon 20 a nac3fca Interface pluggable Push Pull Connectors from Weidmuelle...

Страница 8: ...eries is an analog interface The output voltage is linearly proportional to the adjusted analog control signal If the control signal 0V and or 0A applies the power supply delivers 0V at the output The...

Страница 9: ...urrent to the output This special behaviour is a protection for the power supply and for the connected load Compensation of Load Line Drop Voltage Sense standard operation mode The CPS i power supply...

Страница 10: ...ibution in parallel operation of several identical CPS i units Define the power supply as the master which you want to address with your control A coding of the power modules as the master or the slav...

Страница 11: ...ternatively a voltage of 10 to 30V typ 12V 1 5mA 24V 5 5mA can be applied If the standby repeals the power supply starts with a delay of 500ms Using the soft start the current and the voltage rises wi...

Страница 12: ...y contacts changeover The contacts of CON1 Pin1 and CON1 Pin3 are closed relay coil is energized when the input voltage is higher than typ 175Vac or 210Vdc switch on The contacts of CON1 Pin5 and CON1...

Страница 13: ...tween the TEMP signal and power output is a reinforced isolation of max 400Vdc and a basic isolation of max 600Vdc working voltage Temperature Control Signal PSOT of the PowerSink Fast Down Programmin...

Страница 14: ...0A 24Vdc 125A 3000 3000W CPS i3000 060 60Vdc 50A 48Vdc 62 5A 3000 3000W CPS i3000 090 90Vdc 33 3A 72Vdc 41 5A 2997 2988W CPS i3000 150 150Vdc 20A 120Vdc 25A 3000 3000W CPS i3000 300 300Vdc 10A 240Vdc...

Страница 15: ...her power supplies are not approved for series operation above 60Vdc If the units are remotely controlled via the analog interface it is compulsory to use a potential free control voltage Paralleling...

Страница 16: ...Germany P 16 22 04 2016 01 5 Tel 49 721 46596 0 Fax 49 721 46596 77 www camtec gmbh com info camtec gmbh com Subject to alterations This product is not designed to be used in applications such as lif...

Страница 17: ...l Safety Factory Test Field Test Owner 60Vdc 2800Vdc Type and factory test are the manufacturer While repating damage can happen to the power supply unit For the field test owner follow the below inst...

Страница 18: ...sult in injury or death Mechanics Aluminium housing IP20 Cooling is achieved via front to rear fans To ensure adequate heat dissipation 50mm to the front and 150mm blockade free distance from the devi...

Страница 19: ...lectronic current sink is used the output voltage remains constant at the set value The current sink provides fast dynamic response Fig 1 Fig 2 Fig 3 A Power Sink see Fig 1 enables fast down programmi...

Страница 20: ...ww camtec gmbh com info camtec gmbh com Subject to alterations This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in inj...

Страница 21: ...to custom design power supplies Steplessly hard mount of the CPS i2000 3000 power supply modules in a 3D room In practice that means that one can mount the modules into every angle imaginable Our 3D H...

Страница 22: ...3U 5 Modules mountable only in conjunction with front panel 3U orderable 2201005001CA 19 Rack Rail 2x Support Rails for rack mount mounting kit included 2201008001CA Cable Management Rail Cable suppor...

Отзывы: