CPS-i3000(R2) MANUAL 

Camtec Power Supplies GmbH  -  Gewerbestrasse 30  -  DE-76327  Pfinztal / Germany   

P.22/22 (04/2016.01.5) 

Tel. +49 (721) 46596 - 0  Fax +49 (721) 46596 - 77    

www.camtec-gmbh.com

   -   

[email protected]

 

(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death) 

 

Ordering Codes 

Product Code

 

Information 

Article Number 

CPS-i3000.018(R2) 

0-18Vdc model incl. analogue interface 

3041107001CA 

CPS-i3000.030(R2) 

0-30Vdc model incl. analogue interface 

3041107002CA

 

CPS-i3000.060(R2) 

0-60Vdc model incl. analogue interface 

3041107003CA

 

CPS-i3000.090(R2) 

0-90Vdc model incl. analogue interface 

3041107004CA

 

CPS-i3000.150(R2) 

0-150Vdc model incl. analogue interface 

3041107005CA

 

CPS-i3000.300(R2) 

0-300Vdc model incl. analogue interface 

3041107006CA

 

CPS-i3000.018.PS(R2) 

0-18Vdc model incl. analogue interface and PowerSink / Fast Down Programming 

3041107011CA 

CPS-i3000.030.PS(R2) 

0-30Vdc model incl. analogue interface and PowerSink / Fast Down Programming

 

3041107012CA

 

CPS-i3000.060.PS(R2) 

0-60Vdc model incl. analogue interface and PowerSink / Fast Down Programming

 

3041107013CA

 

CPS-i3000.090.PS(R2) 

0-90Vdc model incl. analogue interface and PowerSink / Fast Down Programming

 

3041107014CA

 

CPS-i3000.150.PS(R2) 

0-150Vdc model incl. analogue interface and PowerSink / Fast Down Programming

 

3041107015CA

 

CPS-i3000.300.PS(R2) 

0-300Vdc model incl. analogue interface and PowerSink / Fast Down Programming

 

3041107016CA

 

Certifacte Calibration 

Separate works certificate for manufacturer calibration of the power supply 

4031107001CA 

19“ Frontplate 2U 

Mounting Kit Included 

2201006001CA 

19“ Frontplate 3U 

Mounting Kit Included

 

2201007001CA 

19“ Blindplate 2U 

Mounting Kit Included

 

2201009001CA 

19“ Blindplate 3U 

Mounting Kit Included

 

2201010001CA 

19“ Subrack 2U 

3 Modules mountable only in conjunction with front panel 2U orderable 

2201004001CA 

19“ Subrack 3U 

5 Modules mountable only in conjunction with front panel 3U orderable 

2201005001CA 

19“ Rack-Rail 

2x Support Rails for rack mount, mounting kit included 

2201008001CA 

Cable Management Rail 

Cable support for rack mount, mounting kit included 

In preparation 

Hard Mount Holder narrow 

2x Holder for strait wall mount, mounting kit included 

2201011001CA 

Hard Mount Holder flat 

2x Holder for flat wall mount, mounting kit included 

2201012001CA 

 
 
 
 
 
 

Safety regulations: Please read these instructions completely before using the equipment. Keep these 
instructions on to hand. The device may only be operated by trained specialist staff. 

 

Installation: 

1) The device is designed for devices and systems 
that meet the standard requirements for hazardous 
voltages, power, and fire prevention. 
2.) Installation and service only by trained specialists. 
The AC power must be switched off. The work is to be 
labelled; accidental reconnection of the system must 
be prevented. 
3.) Opening the device, its modification, loosening 
bolts, or operation outside the specified herein 
specification or in an unsuitable environment, has the 
immediate loss of warranty to follow. We disclaim any 
responsibility for any resulting damage to persons or 
things. 
4.) Note: The device must not be operated without an 
upstream circuit breaker (CB). We recommend the use 
of B-Type 25A. It is prohibited to use the unit without 
PE. It may be necessary upstream device has a power 
switch. 

 

Warning

Non-compliance these warnings can result in fire 
and serious injury or death. 

1. Never operate device

 

without PE connection. 

2. Before connecting the device to the AC 
network, make wires free of voltage and ensure 
that it cannot accidentally switch on. 
3. Allow neat and professional cabling. 
4. Never open nor try to repair the unit. Inside 
are dangerous voltages that can cause electrical 
shock hazard. 
5. Avoid metal pieces or other conductive 
material to fall into the item

 

6. Do not operate the device in damp or wet 
conditions 
7. Do not operate the unit under EX-conditions 

 
 
 

                           All parameters after 15 minutes of continuous operation at full load / 25°C / 230Vac 50/60Hz, unless otherwise indicated. 

Содержание CPS-i3000

Страница 1: ...ogramming Real time I V monitoring Reference voltage f autonomous programming CSB Current Share Bus Inhibit for safe interlocking Remote Shutdown Remote Shutdown Power Good Relay AC ok and DC ok Preci...

Страница 2: ...gn specifications call for the highest standards of safety and interference suppression The device was developed in accordance with the requirements of EN61010 1 EN61010 2 201 EN62368 1 and the EMC st...

Страница 3: ...no ticker operation Master Slave Mode Ureg OUT Ireg OUT The master slave mode can be defined in the parallel operation One device can be set as the master the other involved network units act as a sla...

Страница 4: ...easuring point distance 10mm Hold Up Time 20ms 230Vac mains buffering at full load Inrush Current 14 6Aeff 20 7Apeak 230Vac active electronic inrush protection no simple NTC Startup Delay typ 1s Softs...

Страница 5: ...nhibit Active Open Collector 9 OT Output Signal Over Temperature Open Collector 10 TA Output Signal Temperature Alarm Open Collector Early warning 11 OCP Output Signal Over Current Protection Open Col...

Страница 6: ...el 49 721 46596 0 Fax 49 721 46596 77 www camtec gmbh com info camtec gmbh com Subject to alterations This product is not designed to be used in applications such as life support systems wherein a fai...

Страница 7: ...C 250Vac 20A Neutrik PowerCon 3x2 5 mm Neutrik NAC3FCA Copy of the original instruction http www neutrik com de powercon powercon 20 a nac3fca Interface pluggable Push Pull Connectors from Weidmuelle...

Страница 8: ...eries is an analog interface The output voltage is linearly proportional to the adjusted analog control signal If the control signal 0V and or 0A applies the power supply delivers 0V at the output The...

Страница 9: ...urrent to the output This special behaviour is a protection for the power supply and for the connected load Compensation of Load Line Drop Voltage Sense standard operation mode The CPS i power supply...

Страница 10: ...ibution in parallel operation of several identical CPS i units Define the power supply as the master which you want to address with your control A coding of the power modules as the master or the slav...

Страница 11: ...ternatively a voltage of 10 to 30V typ 12V 1 5mA 24V 5 5mA can be applied If the standby repeals the power supply starts with a delay of 500ms Using the soft start the current and the voltage rises wi...

Страница 12: ...y contacts changeover The contacts of CON1 Pin1 and CON1 Pin3 are closed relay coil is energized when the input voltage is higher than typ 175Vac or 210Vdc switch on The contacts of CON1 Pin5 and CON1...

Страница 13: ...tween the TEMP signal and power output is a reinforced isolation of max 400Vdc and a basic isolation of max 600Vdc working voltage Temperature Control Signal PSOT of the PowerSink Fast Down Programmin...

Страница 14: ...0A 24Vdc 125A 3000 3000W CPS i3000 060 60Vdc 50A 48Vdc 62 5A 3000 3000W CPS i3000 090 90Vdc 33 3A 72Vdc 41 5A 2997 2988W CPS i3000 150 150Vdc 20A 120Vdc 25A 3000 3000W CPS i3000 300 300Vdc 10A 240Vdc...

Страница 15: ...her power supplies are not approved for series operation above 60Vdc If the units are remotely controlled via the analog interface it is compulsory to use a potential free control voltage Paralleling...

Страница 16: ...Germany P 16 22 04 2016 01 5 Tel 49 721 46596 0 Fax 49 721 46596 77 www camtec gmbh com info camtec gmbh com Subject to alterations This product is not designed to be used in applications such as lif...

Страница 17: ...l Safety Factory Test Field Test Owner 60Vdc 2800Vdc Type and factory test are the manufacturer While repating damage can happen to the power supply unit For the field test owner follow the below inst...

Страница 18: ...sult in injury or death Mechanics Aluminium housing IP20 Cooling is achieved via front to rear fans To ensure adequate heat dissipation 50mm to the front and 150mm blockade free distance from the devi...

Страница 19: ...lectronic current sink is used the output voltage remains constant at the set value The current sink provides fast dynamic response Fig 1 Fig 2 Fig 3 A Power Sink see Fig 1 enables fast down programmi...

Страница 20: ...ww camtec gmbh com info camtec gmbh com Subject to alterations This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in inj...

Страница 21: ...to custom design power supplies Steplessly hard mount of the CPS i2000 3000 power supply modules in a 3D room In practice that means that one can mount the modules into every angle imaginable Our 3D H...

Страница 22: ...3U 5 Modules mountable only in conjunction with front panel 3U orderable 2201005001CA 19 Rack Rail 2x Support Rails for rack mount mounting kit included 2201008001CA Cable Management Rail Cable suppor...

Отзывы: