CPS-i2000(R2) MANUAL
Ordering Codes
Product Code
Information
Article Number
CPS-i2000.018(R2)
0-18Vdc model incl. analogue interface
3041106001CA
CPS-i2000.030(R2)
0-30Vdc model incl. analogue interface
3041106002CA
CPS-i2000.060(R2)
0-60Vdc model incl. analogue interface
3041106003CA
CPS-i2000.090(R2)
0-90Vdc model incl. analogue interface
3041106004CA
CPS-i2000.150(R2)
0-150Vdc model incl. analogue interface
3041106005CA
CPS-i2000.018PS(R2)
0-18Vdc model incl. analogue interface and PowerSink / Fast Down Programming
3041106011CA
CPS-i2000.030PS(R2)
0-30Vdc model incl. analogue interface and PowerSink / Fast Down Programming
3041106012CA
CPS-i2000.060PS(R2)
0-60Vdc model incl. analogue interface and PowerSink / Fast Down Programming
3041106013CA
CPS-i2000.090PS(R2)
0-90Vdc model incl. analogue interface and PowerSink / Fast Down Programming
3041106014CA
CPS-i2000.150PS(R2)
0-150Vdc model incl. analogue interface and PowerSink / Fast Down Programming
3041106015CA
Certificate Calibration
Separate works certificate for manufacturer calibration of the power supply
4031107001CA
19“ Frontplate 2U
Mounting Kit Included
2201006001CA
19“ Frontplate 3U
Mounting Kit Included
2201007001CA
19“ Blindplate 2U
Mounting Kit Included
2201009001CA
19“ Blindplate 3U
Mounting Kit Included
2201010001CA
19“ Subrack 2U
3 Modules mountable only in conjunction with front panel 2U orderable
2201004001CA
19“ Subrack 3U
5 Modules mountable only in conjunction with front panel 3U orderable
2201005001CA
19“ Rack-Rail
2x Rack Rails for rack mount, mounting kit included
2201008001CA
Cable Management Rail
Cable support for rack mount, mounting kit included
In preparation
Hard Mount Holder Strait
2x Holder for strait wall mount, mounting kit included
2201011001CA
Hard Mount Holder Flat
2x Holder for flat wall mount, mounting kit included
2201012001CA
Safety regulations: Please read these instructions completely before using the equipment. Keep these
instructions on to hand. The device may only be operated by trained specialist staff.
Installation:
1) The device is designed for devices and systems
that meet the standard requirements for hazardous
voltages, power, and fire prevention.
2.) Installation and service only by trained specialists.
The AC power must be switched off. The work is to be
labelled; accidental reconnection of the system must
be prevented.
3.) Opening the device, its modification, loosening
bolts, or operation outside the specified herein
specification or in an unsuitable environment, has the
immediate loss of warranty to follow. We disclaim any
responsibility for any resulting damage to persons or
things.
4.) Note: The device must not be operated without an
upstream circuit breaker (CB). We recommend the use
of B-Type 16A. It is prohibited to use the unit without
PE. It may be necessary upstream device has a power
switch.
Warning
:
Non-compliance these warnings can result in fire
and serious injury or death.
1. Never operate device
without PE connection.
2. Before connecting the device to the AC
network, make wires free of voltage and ensure
that it cannot accidentally switch on.
3. Allow neat and professional cabling.
4. Never open nor try to repair the unit. Inside
are dangerous voltages that can cause electrical
shock hazard.
5. Avoid metal pieces or other conductive
material to fall into the item
6. Do not operate the device in damp or wet
conditions
7. Do not operate the unit under EX-conditions
All parameters after 15 minutes of continuous operation at full load / 25°C / 230Vac 50/60Hz, unless otherwise indicated.
www.powersolve.co.uk