www.camplux.com
20
For clearances not specified in ANSI Z223.1/NFPA 54 or CSA-B149.1, one of the following shall be indicated:
A) A minimum clearance value determined by testing in accordance with Clause 5.20 or;
B) A reference to the following footnote:
Clearance in accordance with local installation codes and the requirements of the gas supplier.
•
A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single
family dwellings and serves both dwellings.
•
Permitted only if veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor.
NOTES:
1. In accordance with the current CSA B129.1 propane installation code.
2. In accordance with the current ANSI Z223.1/NFPA 54 National fuel gas code.
INSTALLING THE WATER HEATER,CONTINUED
1/4” Per Feet Downward Slope
6” Clearance
12“ Minimum
To drain,dispose of condensate
in accrdance to local codes
Typical Horizontal Termination
W1/4” Per Feet Downward Slope
Support
Hanger
Vent
Adapter
9.8“
9.8“
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
Содержание CA528
Страница 43: ......
Страница 44: ...Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 844 538 7475 ...