Table 9-2: VWIRE 305 settings
Setting
(alphabetically)
Definition
DVW Toolbox
location,
options/range
CRBasic Editor
instruction,
parameter (arguments)
Channel
Enable
Activates a VWIRE 305
input channel
l
Main window,
left
l
Enable column
check box
l
CDM_VW300Config()
l
ChanEnable (0 or
1)
CPI Address
Address of VWIRE 305
on the CPI network
l
Main window,
lower left
l
1 to 120
l
CDM_VW300Config()
l
CPIAddress (1 to
120)
CPI Speed
Rate of CPI network
communications.
Default is usually OK.
l
Main window,
lower center
l
Auto-Detect, 50,
125, 250, 500,
1000 (kbps)
l
CPISpeed()
l
BitRate (50, 125,
250, 500, and
1000 kbps)
l
Usually optional. Default
is 250 if
CPISpeed()
not in program.
Device Name
Optional VWIRE 305
alphanumeric name.
l
Main window,
lower left
l
Optional
l
Visible in the CPI_Status
Table
Device Type
Identifies the VWIRE
305 to CRBasic.
l
Main window
l
Auto detected
l
CDM_VW300Config()
l
DeviceType
VWIRE305
DVW Toolbox
Update Rate
DVW Toolbox data
display rate. Default is
usually OK.
l
Click View >
Advanced
l
Main window,
lower right
n/a
High-
Frequency
Boundary
Upper boundary of
the operator-
determined range of
valid resonant
frequencies. See
36).
l
Click Settings
l
Range: 290 to
6000 Hz
l
View/set in main
window
l
CDM_VW300Config()
l
HighFreq (290 to
6000 Hz)