![Campbell SnowVUE 10 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/campbell/snowvue-10/snowvue-10_product-manual_3925216022.webp)
Table 8-2: SDI-12 commands
SDI-12
1
command
Values returned or
function
Units
Max. sensor
response
time
a
M3!
,
a
C3!
1. Distance
2. Quality number
3. Reference temperature
1. m
2. N/A
3. ° C
20 sec
a
M4!
,
a
C4!
1. Snow depth
2. Quality number
3. Reference temperature
1. m
2. N/A
3. ° C
20 sec
a
M9!
,
a
C9!
1. External temperature
2. Internal temperature
3. Internal RH
4. Pitch
5. Roll
6. Supply voltage
7. Resonant frequency
(should be 50 kHz)
8. Alert flag
0 = good
1 = transducer outside of
normal operating range
1. ° C
2. ° C
3. %
4. °
5. °
6. V
7. kHz
8. N/A
3 sec
a
R3!
Returns the CPU temperature
° C
a
I!
a14CampbellSnow10SN=nnnnn
SDI-12 address: a
SDI-12 version: 14
vendor: Campbell
model: Snow10
SN = Serial number (5 digits)
a
V!
1. Operating system (OS)
version
2. Hardware version
3. Watchdog errors
4. Uptime
1. N/A
2. N/A
3. N/A
4. sec
?!
SDI-12 address
SnowVUE 10 Sonic Ranging Sensor
17