The following table summarizes the hardware settings for this type of network. For detailed
instructions on setting up the hardware and data logger support software see:
B.2.1 Configuring the RF451/RF452 radio connected to the computer
B.2.2 Configuring the data logger acting as a repeater
B.2.3 Adding the endpoint/repeater data logger to the LoggerNet network
B.2.4 Adding endpoint data loggers to the network
B.2.5 Using additional communications methods
Table B-2: RF451/RF452 settings for RF451/RF452 communications with multiple data loggers
using one repeater
Gateway
Endpoint/repeater
Endpoint(s)
Hardware
RF451/RF452 connected
to computer running
LoggerNet
RF451/RF452 connected to
data logger CS I/O port
RF451/RF452 connected to
data logger CS I/O port
PakBus
Address
4094
2
3
Keep all factory default settings except:
Active
Interface
USB or RS-232 (to match
how
LoggerNet
will be
communicating with the
radio)
CS I/O SDC (with SDC
Address set to an unused
SDC address on the data
logger)
CS I/O SDC (with SDC
Address set to an unused
SDC address on the data
logger)
Radio
Operation
Mode
Gateway
Endpoint/Repeater
Endpoint
RF451/RF452 Spread Spectrum Radio
31