Appendix A. Installation Scenarios
FIGURE A-2. DevConfig Screen Showing Master Radio Settings for
Example 1
TABLE A-1. RF450 Settings for Example 1
Master
Slave(s)
Hardware
RF450 connected to PC running
LoggerNet
RF450 connected to CR1000's CS I/O
port
Keep all factory default settings except:
Radio Operation Mode Multi-Point Master
Multi-Point Slave
Network ID
1726 (yours may be different)
1726 (yours may be different)
Frequency Key
1 (yours may be different)
1 (yours may be different)
Radio ID
4094 (to match
LoggerNet’s
PakBus
Address)
2 (to match CR1000's PakBus
Address) (a)
(a) All Slave Radios in the network will have these same settings except for the Radio ID. The Radio ID
should match the PakBus Address of the datalogger it is connected to.
The Device Map in
LoggerNet’s
Setup screen will look something like this:
A-2