background image

MMW-005 Solid State Wind Sensor 

__________________________________________________________________________________________ 

 
TABLE OF CONTENTS 
 
1. Introduction........................................................................................2 
2. Principle 

of Operation ........................................................................3 

3. Specifications ....................................................................................3 
4. Installation .........................................................................................4 
5. Wiring ................................................................................................6 

5.1. 

Output String According to NMEA 0183:........................................................7 

6. CR1000 

Example Program ................................................................7 

7. Maintenance ......................................................................................9

 

 
 

TABLE OF FIGURES 

 

Figure 1  MMW-005 Sensor & Mounting Base .........................................2 
Figure 2  Integrated Circuit ......................................................................2 
Figure 3  C2410 Mounting Bracket ..........................................................4 
Figure 4  Mounting Base Separated from Sensor ....................................5 
Figure 5  Mounting Base Attached ...........................................................5 
Figure 6  True North Orientation Mark .....................................................6 
Figure 7  MMW-005 Mounted ..................................................................6 

 

Содержание MMW-005

Страница 1: ...INSTRUCTION MANUAL Copyright 2008 Campbell Scientific Canada Corp MMW 005 Solid State Wind Sensor Dec 2010...

Страница 2: ...glect accidents of nature or shipping damage This warranty is in lieu of all other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CSC is no...

Страница 3: ...ications 3 4 Installation 4 5 Wiring 6 5 1 Output String According to NMEA 0183 7 6 CR1000 Example Program 7 7 Maintenance 9 TABLE OF FIGURES Figure 1 MMW 005 Sensor Mounting Base 2 Figure 2 Integrate...

Страница 4: ...ip to measure wind speed and wind direction based on the temperature differences across the chip surface These temperature differences are processed by a small microprocessor in the sensor resulting i...

Страница 5: ...speed and direction Guide discs along the top and bottom of the sensor ensure that wind passes through the sensor in the correct manner Mathematical processing by the microprocessor and signal conditi...

Страница 6: ...0183 protocol serial Baud rate 4800 Data bits 8 Stop bits 1 Parity none 4 Installation The MMW 005 is mounted to either a horizontal or vertical pipe with the use of the C2410 Mounting Bracket Figure...

Страница 7: ...racket It is recommended to leave the sensor cable in place as it can slide into the notch provided at the tip of the bracket Figure 5 Mounting Base Attached Before reattaching the MMW 005 to the moun...

Страница 8: ...need to push the sensor into the base until it is completely secured Figure 7 Figure 7 MMW 005 Mounted The MMW 005 and C2410 can now be mounted to the intended pipe using the provided v bolt and hard...

Страница 9: ...eather Instruments MWV Wind speed and direction ddd Wind direction value 0 359 R Relative to the vessel not applicable ss s Wind speed value 0 25 5 m s M Unit for wind speed m s A Data always valid fo...

Страница 10: ...Mean_Horizontal_Wnd_Spd Unit_Vector_Mean_Wnd_Dir Standard_Deviation_Wnd_Dir EndTable DataTable Wnd10Min True 1 DataInterval 0 10 Min 10 10 minute average of WindDir and WindSpeed WindVector 1 Wind_Sp...

Страница 11: ..._________________________________________________________ NextScan EndProg 7 Maintenance The wind sensor has no moving parts and requires no other maintenance than the cleaning of the sensor itself Th...